Influence of adsorption parameters on phenolic compounds removal from aqueous solutions: A mini review

被引:5
|
作者
Mamman, Suwaibatu [1 ]
Abdullahi, Shehu Sa'ad [2 ]
Birniwa, Abdullahi Haruna [3 ]
Opaluwa, Obaje Daniel [1 ]
Mohammad, Rania Edrees Adam [4 ]
Okiemute, Omu [5 ]
Suleiman, Sumayya Balarabe [6 ]
Jagaba, Ahmad Hussaini [7 ]
机构
[1] Nasarawa State Univ Keffi, Fac Nat & Appl Sci, Dept Chem, PMB 1022, Keffi, Nasarawa State, Nigeria
[2] Hussaini Adamu Fed Polytech Kazaure, Dept Polymer Technol, PMB 5004, Kazaure, Jigawa State, Nigeria
[3] Sule Lamido Univ, Dept Chem, PMB 048, Kafin Hausa, Jigawa State, Nigeria
[4] Open Univ Sudan, Fac Educ Sci Dept, Khartoum, Sudan
[5] Fed Polytech, Dept Sci Lab Technol, Ekowe, Bayelsa State, Nigeria
[6] Bayero Univ Kano, Coll Hlth Sci, Fac Basic Med Sci, Dept Biochem, PMB 3011, Kano, Nigeria
[7] King Fahd Univ Petr & Minerals, Interdisciplinary Res Ctr Membranes & Water Secur, Dhahran 31261, Saudi Arabia
关键词
Adsorption; Aqueous solutions; Industrial wastewater; Phenolic compounds; Environmental sustainability; POLYMERIC ADSORBENT; ACTIVATED CARBON; WATER; EQUILIBRIUM;
D O I
10.1016/j.dwt.2024.100631
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Phenol and its derivatives are pollutants of great environmental concern due to their acute toxicity even in minute amounts, to both aquatic life and people. Many regulatory bodies have tagged them as priority pollutants. Phenol levels exceeding the acceptable limit in our environment is no longer a new issue and there is a rise in contamination of phenol due to rapid industrialization. Thus, the increased interest in this pollutant's investigation is related to the significance and urgency of its removal. Several methods are currently used for the removal of phenol and its derivatives from aqueous solutions. Each method is associated with its advantages and disadvantages but by far adsorption using adsorbent is the most widely used method. The sorption of phenolic compounds is a very complex process, and many factors influence it. This paper presents a summary of the sorption of phenolic compounds from aqueous solutions. Several parameters influencing the adsorption capacity phenolic compound such as sorption capacity, removal efficiency, effects of pH, contact time, effect sorbent dosage, concentration and temperature by various adsorbents have been reviewed.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] APPLICATION OF ADSORPTION PROCESS FOR PHENOLIC COMPOUNDS REMOVAL FROM AQUEOUS ENVIRONMENTS: A SYSTEMATIC REVIEW
    Bazrafshan, E.
    Amirian, P.
    Mahvi, A. H.
    Ansari-Moghaddam, A.
    GLOBAL NEST JOURNAL, 2016, 18 (01): : 146 - 163
  • [2] Kinetic and isotherm studies of adsorption and biosorption processes in the removal of phenolic compounds from aqueous solutions: comparative study
    Gholizadeh, Abdolmajid
    Kermani, Majid
    Gholami, Mitra
    Farzadkia, Mehdi
    JOURNAL OF ENVIRONMENTAL HEALTH SCIENCE AND ENGINEERING, 2013, 11
  • [3] Boron removal from aqueous solutions by adsorption - A review
    Guan, Zhimin
    Lv, Jiafei
    Bai, Peng
    Guo, Xianghai
    DESALINATION, 2016, 383 : 29 - 37
  • [4] Kinetic and isotherm studies of adsorption and biosorption processes in the removal of phenolic compounds from aqueous solutions: comparative study
    Abdolmajid Gholizadeh
    Majid Kermani
    Mitra Gholami
    Mehdi Farzadkia
    Journal of Environmental Health Science and Engineering, 11
  • [5] Removal of Phenolic Compounds from Aqueous Phase by Adsorption onto Polymer Supported Iron Nanoparticles
    Sen, Bhupendra K.
    Deshmukh, Dhananjay K.
    Deb, Manas K.
    Verma, Devsharan
    Pal, Jolly
    BULLETIN OF ENVIRONMENTAL CONTAMINATION AND TOXICOLOGY, 2014, 93 (05) : 549 - 554
  • [6] The removal of phenolic compounds from aqueous solutions by organophilic bentonite
    Akçay, M
    Akçay, G
    JOURNAL OF HAZARDOUS MATERIALS, 2004, 113 (1-3) : 189 - 193
  • [7] Adsorption for the removal of phenolic compounds from the effluent of a biologic reactor
    Vacca J, V.
    Colina, G.
    Rincon, N.
    Diaz, A.
    Behling, E.
    Marin, J.
    Chacin, E.
    Fernandez, N.
    REVISTA TECNICA DE LA FACULTAD DE INGENIERIA UNIVERSIDAD DEL ZULIA, 2012, 35 (03): : 252 - 260
  • [8] Determination of optimal operating parameters for tetracycline removal by adsorption from synthetic and real aqueous solutions
    de Carvalho Costa, Leticia Reggiane
    Ribeiro, Luana de Moraes
    Navarro Hidalgo, Gelsa Edith
    Feris, Liliana Amaral
    JOURNAL OF ENVIRONMENTAL SCIENCE AND HEALTH PART A-TOXIC/HAZARDOUS SUBSTANCES & ENVIRONMENTAL ENGINEERING, 2020, 55 (14): : 1615 - 1623
  • [9] Removal of phenolic compounds from aqueous solutions by adsorption onto manganese nodule leached residue
    Parida, K. M.
    Pradhan, Amaresh C.
    JOURNAL OF HAZARDOUS MATERIALS, 2010, 173 (1-3) : 758 - 764
  • [10] A new phenolic hydroxyl modified polystyrene adsorbent for the removal of phenolic compounds from their aqueous solutions
    Li, AM
    Long, C
    Sun, Y
    Zhang, QX
    Liu, FQ
    Chen, JL
    SEPARATION SCIENCE AND TECHNOLOGY, 2002, 37 (14) : 3211 - 3226