The wettability of complete denture base materials constructed by conventional versus digital techniques: an in-vitro study

被引:0
|
作者
Hanno, Kenda I. [1 ]
Metwally, Nayrouz Adel [1 ]
机构
[1] Univ Alexandria, Fac Dent, Dept Prosthodont, Champol St, Alexandria, Egypt
来源
BMC ORAL HEALTH | 2024年 / 24卷 / 01期
关键词
Wettability; Contact angle; Heat-polymerized; 3D-printed; CAD-CAM; ACRYLIC RESIN; CAD/CAM; SALIVA;
D O I
10.1186/s12903-024-04800-x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Background Decreased salivary flow can make the patients uncomfortable with their complete dentures and affects the retention of the dentures. Milling and 3D printing have become an alternative to conventional denture construction techniques. The goal of this study was to evaluate the effect of conventional and digital techniques of the complete denture construction on the denture surface wettability with distilled water and saliva substitute before and after thermocycling. Methods A total of 30 specimens were utilized in the present study. Specimens were divided according to the construction techniques into 3 groups (n = 10 each). Group I: Heat-polymerized polymethylmethacrylate (PMMA) group, group II: Milled group, and group III: 3-dimensional (3D)-printed group. All the specimens were subjected to 2000 cycles of thermal aging in a thermocycler. The wettability of all specimens to water and saliva substitute was measured via a contact angle goniometer (Olympus TGHM, Rame-hart Inc, USA) before and after thermocycling. Descriptive statistical analysis, plots, and the Shapiro-Wilk test were used to verify normality for each variable. One-way ANOVA was used to compare the 3 study groups, while paired samples t-test was used to compare the differences within each group (P < .05). Results The smallest contact angle of drop of water to the denture base specimens before and after thermocycling were recorded in the milled group (53.0 +/- 4.77 and 50.27 +/- 2.30, respectively), followed by the heat polymerized PMMA group (85.65 +/- 4.71 and 65.06 +/- 2.27, respectively), and the 3D-printed group (91.34 +/- 6.74 and 90.86 +/- 8.57, respectively). While the smallest contact angle of drop of saliva substitute to denture base specimens was recorded in the milled group (56.82 +/- 2.29 and 34.85 +/- 7.51, respectively), followed by the 3D-printed group (72.87 +/- 4.83 and 58.14 +/- 9.58, respectively) and the heat polymerized PMMA group (83.62 +/- 4.12 and 67.82 +/- 4.93, respectively). There was statistically significant difference between the groups (P < .05). A significant decline in the average contact angle of drop of saliva has been reported in all groups after thermocycling. The contact angle values differed significantly between saliva substitute and distilled water in both 3D-printed and milled groups after thermocycling (P < .001). Conclusions The milled denture base material presented the best wettability to water and saliva substitute than the 3D-printed and the heat-polymerized PMMA materials. Saliva substitutes improve the wetting ability of denture base materials manufactured by CAD/CAM compared with water.
引用
收藏
页数:8
相关论文
共 23 条
  • [1] Wettability of three denture base materials to human saliva, saliva substitute, and distilled water: A comparative in vitro study
    Ramanna, Pavithra K.
    JOURNAL OF INDIAN PROSTHODONTIC SOCIETY, 2018, 18 (03) : 248 - 256
  • [2] Effect of thermocycling on surface topography and fracture toughness of milled and additively manufactured denture base materials: an in-vitro study
    Mohamed M. Abdul-Monem
    Kenda I. Hanno
    BMC Oral Health, 24
  • [3] Effect of thermocycling on surface topography and fracture toughness of milled and additively manufactured denture base materials: an in-vitro study
    Abdul-Monem, Mohamed M.
    Hanno, Kenda I.
    BMC ORAL HEALTH, 2024, 24 (01)
  • [4] The effect of various denture cleansers on the physical and mechanical properties of CAD/CAM and heat-polymerized denture base materials: an in vitro study
    Selin, Ozyurt Tekin
    Ipek, Caglar
    CLINICAL ORAL INVESTIGATIONS, 2024, 28 (11)
  • [5] Soft Denture Liner Adhesion to Conventional and CAD/CAM Processed Poly(Methyl Methacrylate) Acrylic Denture Resins-An In-Vitro Study
    Al Taweel, Sara Mohammad
    Al-Otaibi, Hanan Nejer
    Labban, Nawaf
    AlFouzan, Afnan
    Shehri, Huda Al
    MATERIALS, 2021, 14 (21)
  • [6] Analysis of the Surface Roughness of Different Denture Teeth Materials: A Quantitative In-Vitro Study
    Sultan, Sherif El Sayed
    Salloum, Mahmoud Gamal
    JOURNAL OF PHARMACY AND BIOALLIED SCIENCES, 2024, 16 : S2494 - S2496
  • [7] Retention Capacity of Original Denture Adhesives and White Brands for Conventional Complete Dentures: An In Vitro Study
    Mendes, Joana
    Mendes, Jose Manuel
    Barreiros, Pedro
    Aroso, Carlos
    Silva, Antonio Sergio
    POLYMERS, 2022, 14 (09)
  • [8] Conventional and Digital Impressions for Fabrication of Complete Implant-Supported Bars: A Comparative In Vitro Study
    Vieira, Samanta N. V.
    Lourenco, Matheus F.
    Pereira, Rodrigo C.
    Franca, Esdras C.
    Vilaca, Enio L.
    Silveira, Rodrigo R.
    Silva, Guilherme C.
    MATERIALS, 2023, 16 (11)
  • [9] Effects of Smokeless Tobacco on Color Stability and Surface Roughness of 3D-Printed, CAD/CAM-Milled, and Conventional Denture Base Materials: An In Vitro Study
    Mugri, Maryam H. H.
    Jain, Saurabh
    Sayed, Mohammed E. E.
    Halawi, Amjad Hussain Asiri
    Hamzi, Safa Ahmed Ibrahim
    Aljohani, Raniya Abdulaziz Saad
    Madkhali, Zainab Mousa Ali
    Khalid, Asaad
    Jokhadar, Hossam F. F.
    Almarzouki, Mai
    Alhumaidan, Ghaida A. A.
    Alshahrani, Ahid Amer
    Alqahtani, Saeed M. M.
    Alqahtani, Nasser M. M.
    Lunkad, Honey
    BIOMEDICINES, 2023, 11 (02)
  • [10] Comparative evaluation of fracture resistance of anterior provisional restorations fabricated using conventional and digital techniques - An in vitro study
    Alam, Maqbul
    Chugh, Anshul
    Kumar, Adarsh
    Rathee, Manu
    Jain, Prachi
    THE JOURNAL OF INDIAN PROSTHODONTIC SOCIETY, 2022, 22 (04) : 361 - 367