Evaluation of the Tribocorrosion Behavior of Ti-6Al-4V Biomedical Alloy in Simulated Oral Environments

被引:2
作者
Fangaia, Sonia I. G. [1 ,2 ,3 ]
Messias, Ana [1 ,4 ]
Guerra, Fernando A. D. R. A. [1 ,3 ]
Ribeiro, Ana C. F. [2 ]
Valente, Artur J. M. [2 ]
Nicolau, Pedro M. G. [1 ,3 ]
机构
[1] Univ Coimbra, Fac Med, Inst Implantol & Prosthodont, P-3000075 Coimbra, Portugal
[2] Univ Coimbra, Coimbra Chem Ctr CQC, Dept Chem, P-3004535 Coimbra, Portugal
[3] Univ Coimbra, Fac Med, Ctr Innovat & Res Oral Sci CIROS, P-3000075 Coimbra, Portugal
[4] Univ Coimbra, Ctr Mech Engn Mat & Proc CEMMPRE, Dept Engn Mecan, P-3030788 Coimbra, Portugal
关键词
dental alloys; wear; surface roughness; Ti-6Al-4V; tribocorrosion; COMMERCIALLY PURE TITANIUM; CORROSION BEHAVIOR; FLUORIDE CONCENTRATION; GALVANIC CORROSION; WEAR; AMALGAM; FATIGUE; RESISTANCE; PH; ROUGHNESS;
D O I
10.3390/pr12071283
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
The sliding wear of Ti-6Al-4V alloys coexisting with dental amalgam in a simulated temperature-controlled cell was evaluated. Disc-shaped samples of Ti-6Al-4V (n = 30) and spherical silver amalgam (n = 30) were prepared. Discs were subjected to wear while immersed in artificial and fluoridated saliva as follows: Ti-6Al-4V-Ti-6Al-4V (G1); amalgam-amalgam (G2), and Ti-6Al-4V-amalgam (G3). Samples were analyzed for mass variation, volume loss, and surface roughness. Wear tracks were characterized by scanning electron microscopy. Wearing induced significant mass loss for all groups except G3 in fluoridated saliva: Ti-6Al-4V (p = 0.045) and amalgam (p = 0.732). These samples presented an increase in mean surface roughness (p = 0.032 and 0.010, respectively). Overall, Ti-6Al-4V showed 0.07 mm3 (95% CI: [0.06-0.07]) higher wear track volume. Ti-6Al-4V has a higher mass loss when subjected to fluoridated media but no significant roughness variation. Fluor-containing substances should be avoided over Ti-6Al-4V alloys placed in areas of mechanical wear, especially if dental amalgam is also present.
引用
收藏
页数:14
相关论文
共 42 条
[1]  
[Anonymous], 2018, ISO 6507-1
[2]   CONTACT AND RUBBING OF FLAT SURFACES [J].
ARCHARD, JF .
JOURNAL OF APPLIED PHYSICS, 1953, 24 (08) :981-988
[3]   Sliding wear performances of 316 L, Ti6Al4V, and CoCrMo alloys [J].
Atar, E. .
KOVOVE MATERIALY-METALLIC MATERIALS, 2013, 51 (03) :183-188
[4]   Galvanic corrosion and cytotoxic effects of amalgam and gallium alloys coupled to titanium [J].
Bumgardner, JD ;
Johansson, BI .
EUROPEAN JOURNAL OF ORAL SCIENCES, 1996, 104 (03) :300-308
[5]   Modeling wear of cast Ti alloys [J].
Chan, Kwai S. ;
Koike, Marie ;
Okabe, Toru .
ACTA BIOMATERIALIA, 2007, 3 (03) :383-389
[6]   Fatigue and Fluoride Corrosion on Streptococcus mutans Adherence to Titanium-Based Implant/Component Surfaces [J].
Correa, Cassia Bellotto ;
Pires, Juliana Rico ;
Fernandes-Filho, Romeu Belon ;
Sartori, Rafael ;
Vaz, Luis Geraldo .
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2009, 18 (05) :382-387
[7]   EFFECT OF ABRASION MEDIUM ON WEAR OF STRESS-BEARING COMPOSITES AND AMALGAM INVITRO [J].
DEGEE, AJ ;
PALLAV, P ;
DAVIDSON, CL .
JOURNAL OF DENTAL RESEARCH, 1986, 65 (05) :654-658
[8]   Intra-oral restorative materials wear: Rethinking the current approaches: How to measure wear [J].
DeLong, Ralph .
DENTAL MATERIALS, 2006, 22 (08) :702-711
[9]   Progression of Bio-Tribocorrosion in Implant Dentistry [J].
Dini, Caroline ;
Costa, Raphael C. ;
Sukotjo, Cortino ;
Takoudis, Christos G. ;
Mathew, Mathew T. ;
Barao, Valentim A. R. .
FRONTIERS IN MECHANICAL ENGINEERING-SWITZERLAND, 2020, 6
[10]  
Donachie MJ., 2000, TITANIUM TECHNICAL G, DOI DOI 10.5772/1844