Field investigation on thermal comfort of metro passengers in hot summer and warm winter zone of China: A case study in Guangzhou

被引:5
|
作者
Chen, Zihao [1 ]
Xie, Xinze [1 ]
Hu, Huiming [1 ]
Zhou, Xuanxuan [1 ]
Yang, Yadie [4 ]
Song, Wenfang [1 ,2 ,3 ]
Luh, Ding Bang [1 ]
Li, Xin [1 ]
机构
[1] Guangdong Univ Technol, Sch Art & Design, Guangzhou 510000, Peoples R China
[2] Guangdong Univ Technol, Lab Human Thermophysiol & Ergon, Guangzhou 510000, Peoples R China
[3] Guangdong Univ Technol, Smart Med Innovat Technol Ctr, Guangzhou 510000, Peoples R China
[4] Hong Kong Polytech Univ, Sch Fash & Text, Hunghom, Hong Kong, Peoples R China
关键词
Field study; Thermal comfort; Metro environment; Initial metabolic rates; METABOLIC-RATE; VENTILATION; TRANSITION; TEMPERATURE; ENVIRONMENT; TRANSPORT; RESPONSES; STATIONS; GENDER;
D O I
10.1016/j.enbuild.2024.114633
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In the hot summer and warm winter zone of China, the metro thermal environments and passengers' thermal comfort were rarely examined, influencing factors such as commuter hours and individual factors were less discussed, and understanding them was beneficial for improving human thermal comfort and saving energy. In this study, a field study was undertaken in Guangzhou located in the region during the summer of 2023. Four metro stations and three metro lines were selected, a total of 1481 valid questionnaires were gathered. The results revealed that the metro thermal environment was highly commendable during the hot summer months, with a thermal acceptability vote (TAV) ranging from 81 % to 89 % across the entrance (ET), concourse (CC), platform (PF), and carriage (CR). Furthermore, the upper limit of the 80 % acceptance range for operative temperature (T-op) was 29.11 degrees C in the ET, 27.82 degrees C in the CC, 29.13 degrees C in the PF, and 28.44 degrees C in the CR. These temperatures exceed the actual mean T-op values in these locations, indicating there is a significant potential for energy savings in metro environments. The upper limits of T-op values for passengers with low, medium and high metabolic rates are 30.34 degrees C, 28.92 degrees C, and 28.25 degrees C, respectively. Thermal sensation votes (TSVs) fell well within the comfort zone specified in ISO 7730 (-0.7 < PMV < 0.7) during both peak and off-peak hours. No difference was found in TSVs between the two genders and among the different ages.
引用
收藏
页数:15
相关论文
共 50 条
  • [31] The study on outdoor pedestrian thermal comfort in blocks: A case study of the Dao He Old Block in hot-summer and cold-winter area of southern China
    Ma, Xuan
    Fukuda, Hiroatsu
    Zhou, Dian
    Gao, Weijun
    Wang, Mengying
    SOLAR ENERGY, 2019, 179 (210-225) : 210 - 225
  • [32] A tracked field study of thermal adaptation during a short-term migration between cold and hot-summer and warm-winter areas of China
    Liu, Yanfeng
    Dong, Yu
    Song, Cong
    Wang, Yingying
    Liu, Lulu
    Liu, Jiaping
    BUILDING AND ENVIRONMENT, 2017, 124 : 90 - 103
  • [33] Characteristics of daytime land surface temperature in wind corridor: A case study of a hot summer and warm winter city
    Lai, Shaoxiong
    Zhao, Yujie
    Fan, Yifan
    Ge, Jian
    JOURNAL OF BUILDING ENGINEERING, 2021, 44
  • [34] Impact of building morphology on outdoor thermal comfort in summer afternoons: A case study in Nanjing, China
    Zhan, Zhaoping
    Jia, Ling
    Wang, Peng
    Huang, Lei
    URBAN CLIMATE, 2024, 56
  • [35] Field investigation of thermal comfort with face masks in outdoor spaces in South China: A case study
    Zheng, Zhimin
    Dai, Kunquan
    Zhou, Xiaoqing
    Liu, Jianlin
    Liu, Weiwei
    Lu, Jiaxin
    Fang, Zhaosong
    URBAN CLIMATE, 2023, 51
  • [36] Integrated performance optimization of industrial buildings in relation to thermal comfort and energy consumption: A case study in hot summer and cold winter climate
    Zhou, Bailing
    Wang, Dong
    CASE STUDIES IN THERMAL ENGINEERING, 2023, 46
  • [37] Are There Differences in Thermal Comfort Perception of Children in Comparison to Their Caregivers' Judgments? A Study on the Playgrounds of Parks in China's Hot Summer and Cold Winter Region
    Qi, Jiaojiao
    Wang, Jiangping
    Zhai, Wenya
    Wang, Jingyong
    Jin, Ziliang
    SUSTAINABILITY, 2022, 14 (17)
  • [38] Intermittent heating performance of different terminals in hot summer and cold winter zone in China based on field test
    Duan, Mengfan
    Wu, Yifan
    Sun, Hongli
    Yang, Zixu
    Shi, Wenxing
    Lin, Borong
    JOURNAL OF BUILDING ENGINEERING, 2021, 43
  • [39] Field measurement study of indoor thermal environment of badminton halls in a hot summer and cold winter region in different seasons in China
    Liu, Lin
    Ma, Yong
    Huang, Ruifeng
    Jia, Mengyao
    Liu, Gan
    Zheng, Weitao
    HELIYON, 2024, 10 (15)
  • [40] Outdoor thermal comfort and adaptive behaviors in a university campus in China's hot summer-cold winter climate region
    Huang, Zefeng
    Cheng, Bin
    Gou, Zhonghua
    Zhang, Fan
    BUILDING AND ENVIRONMENT, 2019, 165