Experimental assessment of FRP repairing in concrete cylinders exposed high temperatures

被引:3
作者
Akbulut, Yunus Emrahan [1 ]
Nayir, Safa [1 ]
Altunisik, Ahmet Can [1 ,2 ,3 ]
Kahya, Volkan [1 ]
Sunnetci, Muhammet Oguz [4 ]
Ersoy, Hakan [4 ]
机构
[1] Karadeniz Tech Univ, Fac Engn, Dept Civil Engn, TR-61080 Trabzon, Turkiye
[2] Karadeniz Tech Univ, Earthquake & Struct Hlth Monitoring Res Ctr, TR-61080 Trabzon, Turkiye
[3] Construction Ind Trade Co Ltd, Dynam Acad Software, Trabzon, Turkiye
[4] Karadeniz Tech Univ, Fac Engn, Dept Geol Engn, TR-61080 Trabzon, Turkiye
关键词
Fire; FRP-strengthening; Concrete; Elevated temperature; Experimental analysis; SEM; FIRE-DAMAGED CONCRETE; ELEVATED-TEMPERATURES; MECHANICAL-PROPERTIES; CONFINED CONCRETE; BEHAVIOR; PERFORMANCE; STRENGTH; COMPOSITES; COLUMNS;
D O I
10.1016/j.cscm.2024.e03656
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This study presents an experimental evaluation of fiber-reinforced polymer (FRP) strengthening in concrete specimens damaged by exposure to high temperatures. For this purpose, sixty cylindrical concrete specimens were produced. Specimens exposed to temperatures of 200 degrees C, 400 degrees C, and 600 degrees C were strengthened using carbon and glass FRP fabrics in two or three layers. Compression tests were conducted to assess the strength of the specimens. The impact of temperature, fabric type, and the number of fabric layers on the concrete's strength was thoroughly investigated. Digital microscopy was employed to explore the formation of cracks due to temperature changes, followed by Scanning Electron Microscopy (SEM) analyses to examine the microscopic structural changes in the concrete samples. The study highlights the importance of considering changes in both strength and behavior models together when evaluating the strengthening contributions provided by FRP. The results indicate that FRP applications on firedamaged concrete structures can provide effective strengthening up to 400 degrees C but may be insufficient at temperatures of 600 degrees C and above. Although an effective increase in strength was achieved at 600 degrees C, low levels of ductility were observed, which is undesirable for an engineering structure. Therefore, it has been determined that FRP-strengthening applications may not be effective in reinforced concrete (RC) structural elements exposed to temperatures of 600 degrees C and higher.
引用
收藏
页数:19
相关论文
共 62 条
[1]   Residual compressive strength of plain and fiber reinforced concrete after exposure to different heating and cooling regimes [J].
Abadel, Aref ;
Elsanadedy, Hussein ;
Almusallam, Tarek ;
Alaskar, Abdulaziz ;
Abbas, Husain ;
Al-Salloum, Yousef .
EUROPEAN JOURNAL OF ENVIRONMENTAL AND CIVIL ENGINEERING, 2022, 26 (14) :6746-6765
[2]   Experimental and numerical study on wrapping concrete cylinders post heating and cooling under preload using CFRP fabrics [J].
Al-Kamaki, Yaman S. S. ;
Al-Mahaidi, Riadh ;
Al-Mosawe, Alaa ;
Bennetts, Ian .
STRUCTURES, 2020, 23 :425-436
[3]   An experimental investigation of the behaviour of heat-damaged RC columns confined with CFRP fabrics using photogrammetry [J].
Al-Kamaki, Yaman S. S. ;
Al-Mahaidi, Riadh ;
Bennetts, Ian .
MATERIALS AND STRUCTURES, 2017, 50 (01)
[4]   Experimental and numerical study of the behaviour of heat-damaged RC circular columns confined with CFRP fabric [J].
Al-Kamaki, Yaman S. S. ;
Al-Mahaidi, Riadh ;
Bennetts, Ian .
COMPOSITE STRUCTURES, 2015, 133 :679-690
[5]  
Al-Kamaki YSS, 2013, 4 AS PAC C FRP STRUC, P11
[6]   FRP Confinement of Heat-Damaged Circular RC Columns [J].
Al-Nimry, Hanan Suliman ;
Ghanem, Aseel Mohammad .
INTERNATIONAL JOURNAL OF CONCRETE STRUCTURES AND MATERIALS, 2017, 11 (01) :115-133
[7]   Behavior of FRP-confined concrete after high temperature exposure [J].
Al-Salloum, Yousef A. ;
Elsanadedy, Hussein M. ;
Abadel, Aref A. .
CONSTRUCTION AND BUILDING MATERIALS, 2011, 25 (02) :838-850
[8]   Experimental Study of the Effect of Different Insulation Schemes on Fire Performance of FRP Strengthened Concrete: FIRECOAT and REALROCK [J].
Altunisik, Ahmet Can ;
Akbulut, Yunus Emrahan ;
Adanur, Suleyman ;
Gunaydin, Murat ;
Mostofi, Sara ;
Mosallam, Ayman .
INTERNATIONAL JOURNAL OF CONCRETE STRUCTURES AND MATERIALS, 2023, 17 (01)
[9]   Evaluating the high-temperature endurance of FRP-strengthened concrete using an innovative insulation system: Experimental investigation [J].
Altunisik, Ahmet Can ;
Akbulut, Yunus Emrahan ;
Adanur, Suleyman ;
Kaya, Ali ;
Gunaydin, Murat ;
Mostofi, Sara ;
Mosallam, Ayman .
JOURNAL OF BUILDING ENGINEERING, 2023, 73
[10]   Stress-Strain Behaviour of Normal Compacting and Self Compacting Concrete Under Elevated Temperatures [J].
Anand, N. ;
Arulraj, G. Prince ;
Aravindhan, C. .
JOURNAL OF STRUCTURAL FIRE ENGINEERING, 2014, 5 (01) :63-75