Evaluation of robotic-assisted navigation system for CT-guided thoracic and abdominal lesion puncture: A prospective clinical study

被引:1
|
作者
Jing, Yifan [1 ]
Zhang, Jian [1 ]
Jin, Yong [1 ]
Bai, Xuming [1 ]
机构
[1] Soochow Univ, Affiliated Hosp 2, Dept Intervent Radiol, Suzhou, Jiangsu, Peoples R China
关键词
Accuracy; computer tomography; percutaneous needle insertion; robotic-assisted navigation system; safety; TRANSTHORACIC NEEDLE-BIOPSY; MICROWAVE ABLATION; LIVER-TUMORS; COMPLICATIONS;
D O I
10.4103/jcrt.jcrt_373_24
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Introduction: The study aims to compare the accuracy and safety of robotic-assisted navigation puncture to freehand puncture during computed tomography (CT)-guided percutaneous needle insertion in the chest and abdomen. Methods: A total of 60 patients required percutaneous puncture procedures, with 40 involving the chest and 20 involving the abdomen. Eligible patients were randomly assigned to two groups. The test group punctured using a robotic-assisted navigation system, whereas the control group punctured manually. The primary outcome assessment standards are single puncture success rates, with the number of needle modifications and CT scan timings during the procedure serving as supplementary outcome evaluation standards. The Wilcoxon rank sum test is used for the comparison. Results: The puncture procedure's success rates after just one puncture: The test group punctures accurately without adjusting the puncture needle, while the control group uses an average number of 1.73 +/- 1.20 pins. The once-puncture success rate of robot navigation puncture is considerably higher than that of bare-handed puncture (P < 0.001). The times of CT scan are necessitated when the puncture is in place: the average times in the test group is 3.03 +/- 0.18 times, while the control group is 4.70 +/- 1.24 times. Conclusion: In conclusion, the robotic-assisted navigation system improves puncture accuracy while reducing the need for needle corrections during percutaneous puncture procedures. It also shortens CT scans and reduces radiation exposure from X-rays.
引用
收藏
页码:1350 / 1356
页数:7
相关论文
共 26 条
  • [1] Clinical evaluation of a robotic system for precise CT-guided percutaneous procedures
    Levy, Shiran
    Goldberg, S. Nahum
    Roth, Ido
    Shochat, Moran
    Sosna, Jacob
    Leichter, Isaac
    Flacke, Sebastian
    ABDOMINAL RADIOLOGY, 2021, 46 (10) : 5007 - 5016
  • [2] Percutaneous CT-Guided Abdominal and Pelvic Biopsies: Comparison of an Electromagnetic Navigation System and CT Fluoroscopy
    Zlevor, Annie M.
    Kisting, Meridith A.
    Couillard, Allison B.
    Rossebo, Annika E.
    Szczykutowicz, Timothy P.
    Mao, Lu
    White, James K.
    Hartung, Michael P.
    Gettle, Lori Mankowski
    Hinshaw, J. Louis
    Pickhardt, Perry J.
    Ziemlewicz, Timothy J.
    Foltz, Marcia L.
    Lee, Fred T., Jr.
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2023, 34 (05) : 910 - 918
  • [3] A robotic needle-positioning and guidance system for CT-guided puncture: Ex vivo results
    Kettenbach, Joachim
    Kara, Levent
    Toporek, Grzegorz
    Fuerst, Martin
    Kronreif, Gernot
    MINIMALLY INVASIVE THERAPY & ALLIED TECHNOLOGIES, 2014, 23 (05) : 271 - 278
  • [4] Robotic-assisted CT-guided percutaneous pulmonary nodules localization by hook-wire needles: a retrospective observational study
    Guo, Haoming
    Ouyang, Zubin
    Li, Xinghua
    Han, Yongliang
    Tao, Fengming
    Liu, Mengqi
    Cheng, Runtian
    Chen, Xiaoya
    Lv, Fajin
    Yang, Haitao
    JOURNAL OF THORACIC DISEASE, 2024, 16 (07) : 4263 - 4274
  • [5] Determinants of radiation exposure during mobile cone-beam CT-guided robotic-assisted bronchoscopy
    Kalchiem-Dekel, Or
    Bergemann, Reza
    Ma, Xiaoyue
    Christos, Paul J.
    Miodownik, Daniel
    Gao, Yiming
    Mahmood, Usman
    Adusumilli, Prasad S.
    Bott, Matthew J.
    Dycoco, Joseph
    Gelblum, Daphna Y.
    Lee, Robert P.
    Park, Bernard J.
    Rocco, Gaetano
    Solomon, Stephen B.
    Jones, David R.
    Chawla, Mohit
    Husta, Bryan C.
    RESPIROLOGY, 2024, 29 (09) : 803 - 814
  • [6] Evaluation of a New CT-Guided Robotic System for Percutaneous Needle Insertion for Thermal Ablation of Liver Tumors: A Prospective Pilot Study
    de Baere, Thierry
    Roux, Charles
    Deschamps, Frederic
    Tselikas, Lambros
    Guiu, Boris
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2022, 45 (11) : 1701 - 1709
  • [7] Guided Bronchoscopy for Peripheral Pulmonary Lesion Sampling: The Pros and Cons of Electromagnetic Navigation Bronchoscopy and Robotic-Assisted Bronchoscopy
    Lin, Julie
    Ho, Elliot
    Frye, Laura
    CURRENT PULMONOLOGY REPORTS, 2024, 13 (01) : 95 - 102
  • [8] Evaluation of a novel, patient-mounted system for CT-guided needle navigation—an ex vivo study
    Anna Mokry
    Florian Willmitzer
    Rafael Hostettler
    Henning Richter
    Patrick Kircher
    Sibylle Kneissl
    Stephan Wetzel
    Neuroradiology, 2019, 61 : 55 - 61
  • [9] Robotic-assisted navigation system for preoperative lung nodule localization: a pilot study
    Liu, Jun
    Jiang, Yu
    He, Rui
    Cui, Fei
    Lin, Yuechun
    Xu, Ke
    Cai, Weipeng
    Hao, Zhexue
    Zeng, Yuan
    Chen, Xiangqian
    Zhang, Hao
    Shi, Jipeng
    Cheong, Houiam
    Dong, Mengxing
    Kaicheng, U.
    Huang, Xiaoyan
    Jiang, Shunjun
    Huang, Jun
    Wang, Wei
    Liang, Hengrui
    Duan, Xingguang
    He, Jianxing
    TRANSLATIONAL LUNG CANCER RESEARCH, 2023, 12 (11) : 2283 - +
  • [10] Clinical value of an electromagnetic navigation system for CT-guided percutaneous lung biopsy of peripheral lung lesions
    Zhang, Yao
    Huang, Haozhe
    Cao, Shuhui
    Teng, Jiajun
    Wang, Yue
    Ling, Xuxinyi
    Zhou, Yan
    Xu, Jianlin
    Li, Wentao
    Zhong, Hua
    JOURNAL OF THORACIC DISEASE, 2021, 13 (08) : 4885 - 4893