Test-Retest Reliability of an Isometric and Isometric/Vibratory Muscular Strength Protocol with Functional Electro-Mechanical Dynamometry

被引:2
|
作者
Andrades-Ramirez, Oscar [1 ]
Ulloa-Diaz, David [2 ]
Alfaro Castillo, Bryan [3 ]
Arroyo-Jofre, Patricio [4 ]
Castillo-Paredes, Antonio [5 ]
Chirosa-Rios, Luis [6 ]
机构
[1] Univ las Americas, Escuela Ciencias Act Fis, Fac Salud & Ciencias Sociales, Concepcion 4030000, Chile
[2] Univ Catolica Santisima Concepcion, Dept Sports Sci & Phys Conditioning, Concepcion 4030000, Chile
[3] Univ Atacama, Fac Educ, Copiapo 1531772, Chile
[4] Univ San Sebastian, Fac Educ, Santiago 8420524, Chile
[5] Univ las Americas, Escuela Pedag Educ Fis, Fac Educ, Grp AFySE,Invest Actividad Fis & Salud Escolar, Santiago 8370040, Chile
[6] Univ Granada, Fac Sport Sci, Dept Phys Educ & Sport, Granada 18011, Spain
关键词
muscular strength; reliability; dynamometer; isokinetic; MUSCLE STRENGTH; VARIABLES;
D O I
10.3390/sports12070175
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
The purpose of the study was to analyze the test-retest reliability of an isometric and isometric/vibratory muscular strength protocol in the bilateral seated bench press (BSBP), bilateral seated rowing (BSR), unilateral seated right knee extension (USKER), and left knee extension (USKEL) tests controlled using functional electromechanical dynamometry (FEMD) in healthy young adults. A repeated measures design was used to determine the reliability of a muscular strength protocol in isometric and isometric vibration modes with FEMD. No significant differences were found in test-retest analysis (p > 0.05; ES < 0.20); and high reliability (CV = 4.65-5.02%; ICC = 0.99-0.98) was found for BSBP measures, and acceptable reliability (CV = 3.71-9.61%; ICC = 0.98-0.95) was found for BSR, USKER, and USKEL. Furthermore, the coefficients between the two measures were strong (r = 0.963-0.839) and highly significant (p = 0.001) for maximal strength in the isometric and maximal isometric/vibratory assessment of muscle strength in all muscle strength tests. This study demonstrates that isometric and maximal isometric/vibratory strength in the BSBP, BSR, USKER, and USKEL tests can be measured with high reliability and reproducibility using the FEMD.
引用
收藏
页数:12
相关论文
共 24 条
  • [21] Test-retest reliability of the functional reach test and the hand grip strength test in older adults using nursing home services
    Soraia Ferreira
    Armando Raimundo
    José Marmeleira
    Irish Journal of Medical Science (1971 -), 2021, 190 : 1625 - 1632
  • [22] Test-retest reliability of wavelet - and Fourier based EMG (instantaneous) median frequencies in the evaluation of back and hip muscle fatigue during isometric back extensions
    Coorevits, Pascal
    Danneels, Lieven
    Cambier, Dirk
    Ramon, Herman
    Druyts, Hans
    Karlsson, J. Stefan
    De Moor, Georges
    Vanderstraeten, Guy
    JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2008, 18 (05) : 798 - 806
  • [23] Test-retest reliability and concurrent validity of knee extensor strength measured by a novel device incorporated into a weight stack machine vs. handheld and isokinetic dynamometry
    Sahu, Pradeep K.
    Goodstadt, Noel
    Ramakrishnan, Arun
    Silfies, Sheri P.
    PLOS ONE, 2024, 19 (05):
  • [24] Inter-day test-retest reliability and feasibility of isokinetic, isometric, and isotonic measurements to assess quadriceps endurance in people with chronic obstructive pulmonary disease: A multicenter study
    Frykholm, Erik
    Gephine, Sarah
    Saey, Didier
    van Hees, Hieronymus
    Lemson, Arthur
    Klijn, Peter
    Maltais, Francois
    Nyberg, Andre
    CHRONIC RESPIRATORY DISEASE, 2018, 16