Test-Retest Reliability of an Isometric and Isometric/Vibratory Muscular Strength Protocol with Functional Electro-Mechanical Dynamometry

被引:2
|
作者
Andrades-Ramirez, Oscar [1 ]
Ulloa-Diaz, David [2 ]
Alfaro Castillo, Bryan [3 ]
Arroyo-Jofre, Patricio [4 ]
Castillo-Paredes, Antonio [5 ]
Chirosa-Rios, Luis [6 ]
机构
[1] Univ las Americas, Escuela Ciencias Act Fis, Fac Salud & Ciencias Sociales, Concepcion 4030000, Chile
[2] Univ Catolica Santisima Concepcion, Dept Sports Sci & Phys Conditioning, Concepcion 4030000, Chile
[3] Univ Atacama, Fac Educ, Copiapo 1531772, Chile
[4] Univ San Sebastian, Fac Educ, Santiago 8420524, Chile
[5] Univ las Americas, Escuela Pedag Educ Fis, Fac Educ, Grp AFySE,Invest Actividad Fis & Salud Escolar, Santiago 8370040, Chile
[6] Univ Granada, Fac Sport Sci, Dept Phys Educ & Sport, Granada 18011, Spain
关键词
muscular strength; reliability; dynamometer; isokinetic; MUSCLE STRENGTH; VARIABLES;
D O I
10.3390/sports12070175
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
The purpose of the study was to analyze the test-retest reliability of an isometric and isometric/vibratory muscular strength protocol in the bilateral seated bench press (BSBP), bilateral seated rowing (BSR), unilateral seated right knee extension (USKER), and left knee extension (USKEL) tests controlled using functional electromechanical dynamometry (FEMD) in healthy young adults. A repeated measures design was used to determine the reliability of a muscular strength protocol in isometric and isometric vibration modes with FEMD. No significant differences were found in test-retest analysis (p > 0.05; ES < 0.20); and high reliability (CV = 4.65-5.02%; ICC = 0.99-0.98) was found for BSBP measures, and acceptable reliability (CV = 3.71-9.61%; ICC = 0.98-0.95) was found for BSR, USKER, and USKEL. Furthermore, the coefficients between the two measures were strong (r = 0.963-0.839) and highly significant (p = 0.001) for maximal strength in the isometric and maximal isometric/vibratory assessment of muscle strength in all muscle strength tests. This study demonstrates that isometric and maximal isometric/vibratory strength in the BSBP, BSR, USKER, and USKEL tests can be measured with high reliability and reproducibility using the FEMD.
引用
收藏
页数:12
相关论文
共 24 条
  • [1] Test-Retest Reliability of the Isometric Soleus Strength Test in Elite Male Academy Footballers
    Rhodes, David
    Jeffery, Josh
    Brook-Sutton, Daniel
    Alexander, Jill
    INTERNATIONAL JOURNAL OF SPORTS PHYSICAL THERAPY, 2022, 17 (02): : 286 - 292
  • [2] Test-retest reliability of a handheld dynamometer for measurement of isometric cervical muscle strength
    Vannebo, Katrine Tranaas
    Iversen, Vegard Moe
    Fimland, Marius Steiro
    Mork, Paul Jarle
    JOURNAL OF BACK AND MUSCULOSKELETAL REHABILITATION, 2018, 31 (03) : 557 - 565
  • [3] Test-retest reliability of isometric mid-thigh pull maximum strength assessment: a systematic review
    Grgic, Jozo
    Scapec, Bela
    Mikulic, Pavle
    Pedisic, Zeljko
    BIOLOGY OF SPORT, 2022, 39 (02) : 407 - 414
  • [4] Test-retest reliability of isometric shoulder muscle strength measurement with a handheld dynamometer and belt
    Katoh, Munenori
    JOURNAL OF PHYSICAL THERAPY SCIENCE, 2015, 27 (06) : 1719 - 1722
  • [5] Test-retest reliability of isometric and isoinertial testing in symmetric and asymmetric lifting
    Hattori, Y
    Ono, Y
    Shimaoka, M
    Hiruta, S
    Kamijima, M
    Takeuchi, Y
    ERGONOMICS, 1998, 41 (07) : 1050 - 1059
  • [6] Test-Retest Reliability of Concentric and Eccentric Muscle Strength in Knee Flexion-Extension Controlled by Functional Electromechanical Dynamometry in female Soccer
    Andrades-Ramirez, Oscar
    Ulloa-Diaz, David
    Rodriguez-Perea, Angela
    Araya-Sierralta, Sergio
    Guede-Rojas, Francisco
    Munoz-Bustos, Gustavo
    Chirosa-Rios, Luis-Javier
    APPLIED SCIENCES-BASEL, 2024, 14 (19):
  • [7] Test-retest reliability of hand-held dynamometry and functional tests in systemic lupus erythematosus
    Stockton, K. A.
    Wrigley, T. V.
    Mengersen, K. A.
    Kandiah, D. A.
    Paratz, J. D.
    Bennell, K. L.
    LUPUS, 2011, 20 (02) : 144 - 150
  • [8] Test-retest reliability of isometric shoulder muscle strength during abduction and rotation tasks measured using the Biodex dynamometer
    Croci, Eleonora
    Born, Patrik
    Eckers, Franziska
    Nusch, Corina
    Baumgartner, Daniel
    Muller, Andreas Marc
    Mundermann, Annegret
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2023, 32 (10) : 2008 - 2016
  • [9] A portable isometric knee extensor strength testing device: test-retest reliability and minimal detectable change scores of the Q-Force ӀӀ in healthy adults
    Johanneke Hartog
    Sandra Dijkstra
    Joke Fleer
    Pim van der Harst
    Massimo A. Mariani
    Lucas H. V. van der Woude
    BMC Musculoskeletal Disorders, 22
  • [10] Functional strength measurement in cerebral palsy: feasibility, test-retest reliability, and construct validity
    Aertssen, Wendy
    Smulders, Ellen
    Smits-Engelsman, Bouwien
    Rameckers, Eugene
    DEVELOPMENTAL NEUROREHABILITATION, 2019, 22 (07) : 453 - 461