Failure modes and effects analysis applied to high-dose-rate brachytherapy treatment planning

被引:53
|
作者
Wilkinson, D. Allan [1 ]
Kolar, Matthew D. [1 ]
机构
[1] Cleveland Clin, Dept Radiat Oncol, Cleveland, OH 44195 USA
关键词
Failure modes; High-dose-rate brachytherapy; Treatment planning; QUALITY-ASSURANCE; DELIVERY;
D O I
10.1016/j.brachy.2013.03.002
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
PURPOSE: To apply failure modes and effects analysis to high-dose-rate treatment planning to identify the most likely and significant sources of error in the process. METHODS: We have made a list of 25 failure modes grouped into six categories (imaging, catheter reconstruction, dwell position activity, dose points/normalization, optimization/dose, and evaluation). Each mode was rated on a one to five scale for severity, likelihood of occurrence, and probability of escaping detection. An overall ranking was formed from the product of the three scores. The authors assigned scores independently and the resulting rankings were averaged. We also analyzed 44 reported medical events related to high-dose-rate treatment planning listed on the Nuclear Regulatory Commission Web site and compared them with our own rankings. RESULTS: Failure modes associated with image sets, catheter reconstruction, indexer length, and incorrect dose points had the highest ranking in our analysis (scores higher than 20). The most often cited failure modes in the Nuclear Regulatory Commission reports examined were indexer length (20/44) and incorrect dose points (6/44). Several of our high-ranking modes are not associated with reported events. CONCLUSION: It is a useful exercise to identify failure modes locally and analyze the efficacy of the local quality assurance program. Comparison with nationally reported failures can help direct the local analysis, but the absence or small number of reports for failure modes with a high score may be owing to low detectability. Such modes obviously cannot be ignored. (C) 2013 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:382 / 386
页数:5
相关论文
共 50 条
  • [1] A failure modes and effects analysis study for gynecologic high-dose-rate brachytherapy
    Mayadev, Jyoti
    Dieterich, Sonja
    Harse, Rick
    Lentz, Susan
    Mathai, Mathew
    Boddu, Sunita
    Kern, Marianne
    Courquin, Jean
    Stern, Robin L.
    BRACHYTHERAPY, 2015, 14 (06) : 866 - 875
  • [2] Failure modes and effects analysis in image-guided high-dose-rate brachytherapy: Quality control optimization to reduce errors in treatment volume
    Wadi-Ramahi, Shada
    Alnajjar, Waleed
    Mahmood, Rana
    Jastaniyah, Noha
    Moftah, Belal
    BRACHYTHERAPY, 2016, 15 (05) : 669 - 678
  • [3] Deep reinforcement learning for treatment planning in high-dose-rate cervical brachytherapy
    Pu, Gang
    Jiang, Shan
    Yang, Zhiyong
    Hu, Yuanjing
    Liu, Ziqi
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2022, 94 : 1 - 7
  • [4] Biological Planning for High-Dose-Rate Brachytherapy: Application to Cervical Cancer Treatment
    Lee, Eva K.
    Yuan, Fan
    Templeton, Alistair
    Yao, Rui
    Kiel, Krystyna
    Chu, James C. H.
    INTERFACES, 2013, 43 (05) : 462 - 476
  • [5] An independent dose-to-point calculation program for the verification of high-dose-rate brachytherapy treatment planning
    Cohen, GN
    Amols, HI
    Zaider, M
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2000, 48 (04): : 1251 - 1258
  • [6] A dose verification method for high-dose-rate brachytherapy treatment plans
    Kumar, Rajesh
    Sharma, S. D.
    Vijaykumar, C.
    Deshpande, Sudesh
    Sharma, P. K.
    Vandana, S.
    Philomena, A.
    Chilkulwar, Ravi H.
    JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2008, 4 (04) : 173 - 177
  • [7] QUALITY ASSURANCE TOOL FOR HIGH-DOSE-RATE BRACHYTHERAPY
    DEWERD, LA
    JURSINIC, P
    KITCHEN, R
    THOMADSEN, BR
    MEDICAL PHYSICS, 1995, 22 (04) : 435 - 440
  • [8] A quality assurance tool for high-dose-rate brachytherapy
    Rickey, Daniel W.
    Sasaki, David
    Bews, Jeff
    MEDICAL PHYSICS, 2010, 37 (06) : 2525 - 2532
  • [9] Automated construction of an intraoperative high-dose-rate treatment plan library for the Varian brachytherapy treatment planning system
    Deufel, Christopher L.
    Furutani, Keith M.
    Dahl, Robert A.
    Haddock, Michael G.
    BRACHYTHERAPY, 2016, 15 (04) : 531 - 536
  • [10] American Brachytherapy Society consensus guidelines for high-dose-rate prostate brachytherapy
    Yamada, Yoshiya
    Rogers, Leland
    Demanes, D. Jeffrey
    Morton, Gerard
    Prestidges, Bradley R.
    Pouliot, Jean
    Cohen, Gil'ad N.
    Zaider, Marco
    Ghilezan, Mihai
    Hsu, I-Chow
    BRACHYTHERAPY, 2012, 11 (01) : 20 - 32