Deep learning-based image reconstruction algorithm for lung diffusion weighted imaging: improved image quality and diagnostic performance

被引:1
|
作者
Li, Jie [1 ,2 ]
Xia, Yi [1 ]
Sun, Guangyuan [4 ]
Xu, Meiling [1 ]
Lin, Xiaoqing [1 ,2 ]
Jiang, Song [1 ]
Dai, Jiankun [3 ]
Liu, Shiyuan [1 ]
Fan, Li [1 ]
机构
[1] Naval Med Univ, Affiliated Hosp 2, Dept Radiol, 415 Fengyang Rd, Shanghai 200003, Peoples R China
[2] Univ Shanghai Sci & Technol, Coll Hlth Sci & Engn, 516 Jungong Rd, Shanghai 200093, Peoples R China
[3] GE Healthcare, Beijing 100000, Peoples R China
[4] Naval Med Univ, Affiliated Hosp 2, Dept Thorac Surg, 415 Fengyang Rd, Shanghai 200003, Peoples R China
基金
国家重点研发计划; 中国国家自然科学基金;
关键词
Diffusion weighted imaging; Intravoxel incoherent motion; Deep learning reconstruction; Pulmonary lesions; LESIONS; MRI; CANCER; COEFFICIENT; DIFFERENTIATION; SENSITIVITY;
D O I
10.1007/s42058-024-00168-7
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose To assess the impact of deep learning reconstruction (DLR) on the image quality and the diagnostic performance of lung DWI. Methods Totally 46 patients with 46 lesions (malignant 35, benign 11) were prospectively recruited and imaged with DWI. DWI images were reconstructed with conventional reconstruction (ConR) and DLR, respectively. Two radiologists evaluated the signal-to-noise ratio (SNR), apparent diffusion coefficient (ADC) and IVIM-derived parameters of pulmonary lesions. Intraclass correlation coefficients were used to evaluate reader agreement. Paired t-tests or Wilcoxon tests were used to compare the measurements between DLR and ConR. Differences between different types of lesions were determined using Student's or Mann-Whitney test. ROC curves were used to evaluate the diagnostic performance of the DWI parameters. Results All the measurements with DLR and ConR showed excellent inter-observer consistency. In comparison with ConR, DLR showed higher SNR, higher measurements of ADC and D-slow (all P < 0.001). ADC and f(fast) of malignant lesions was significantly lower than that of benign lesions with DLR and ConR (P < 0.05), respectively, but no difference was found between the two reconstruction algorithms. ROC analysis showed the diagnostic performance of ADC and f(fast) with DLR outweighed ConR slightly for distinguishing malignant from benign lesions. The ADC of DLR can distinguish adenocarcinoma from squamous cell carcinoma significantly (P < 0.001) with AUC 0.734. Conclusion DLR can significantly increase the SNR of lung DWI which affects the DWI quantification, resulting with improved diagnostic performance for distinguishing benign from malignant lesions, especially discriminating adenocarcinoma from squamous cell carcinoma.
引用
收藏
页码:348 / 357
页数:10
相关论文
共 50 条
  • [21] Deep learning-based k-space-to-image reconstruction and super resolution for diffusion-weighted imaging in whole-spine MRI
    Kim, Dong Kyun
    Lee, So-Yeon
    Lee, Jinyoung
    Huh, Yeon Jong
    Lee, Seungeun
    Lee, Sungwon
    Jung, Joon-Yong
    Lee, Hyun-Soo
    Benkert, Thomas
    Park, Sung-Hong
    MAGNETIC RESONANCE IMAGING, 2024, 105 : 82 - 91
  • [22] Deep Learning-Based Dictionary Learning and Tomographic Image Reconstruction
    Rudzusika, Jevgenija
    Koehler, Thomas
    Oktem, Ozan
    SIAM JOURNAL ON IMAGING SCIENCES, 2022, 15 (04): : 1729 - 1764
  • [23] Deep Learning-Based Superresolution Reconstruction for Upper Abdominal Magnetic Resonance Imaging An Analysis of Image Quality, Diagnostic Confidence, and Lesion Conspicuity
    Almansour, Haidara
    Gassenmaier, Sebastian
    Nickel, Dominik
    Kannengiesser, Stephan
    Afat, Saif
    Weiss, Jakob
    Hoffmann, Rudiger
    Othman, Ahmed E.
    INVESTIGATIVE RADIOLOGY, 2021, 56 (08) : 509 - 516
  • [24] Deep learning image reconstruction algorithm for carotid dual-energy computed tomography angiography: evaluation of image quality and diagnostic performance
    Chenyu Jiang
    Dan Jin
    Zhuoheng Liu
    Yan Zhang
    Ming Ni
    Huishu Yuan
    Insights into Imaging, 13
  • [25] Deep learning image reconstruction algorithm for carotid dual-energy computed tomography angiography: evaluation of image quality and diagnostic performance
    Jiang, Chenyu
    Jin, Dan
    Liu, Zhuoheng
    Zhang, Yan
    Ni, Ming
    Yuan, Huishu
    INSIGHTS INTO IMAGING, 2022, 13 (01)
  • [26] Low-dose liver CT: image quality and diagnostic accuracy of deep learning image reconstruction algorithm
    Caruso, Damiano
    De Santis, Domenico
    Del Gaudio, Antonella
    Guido, Gisella
    Zerunian, Marta
    Polici, Michela
    Valanzuolo, Daniela
    Pugliese, Dominga
    Persechino, Raffaello
    Cremona, Antonio
    Barbato, Luca
    Caloisi, Andrea
    Iannicelli, Elsa
    Laghi, Andrea
    EUROPEAN RADIOLOGY, 2024, 34 (04) : 2384 - 2393
  • [27] Low-dose liver CT: image quality and diagnostic accuracy of deep learning image reconstruction algorithm
    Damiano Caruso
    Domenico De Santis
    Antonella Del Gaudio
    Gisella Guido
    Marta Zerunian
    Michela Polici
    Daniela Valanzuolo
    Dominga Pugliese
    Raffaello Persechino
    Antonio Cremona
    Luca Barbato
    Andrea Caloisi
    Elsa Iannicelli
    Andrea Laghi
    European Radiology, 2024, 34 : 2384 - 2393
  • [28] Advanced deep learning-based image reconstruction in lumbar spine MRI at 0.55 T - Effects on image quality and acquisition time in comparison to conventional deep learning-based reconstruction
    Schlicht, Felix
    Vosshenrich, Jan
    Donners, Ricardo
    Seifert, Alina Carolin
    Fenchel, Matthias
    Nickel, Dominik
    Obmann, Markus
    Harder, Dorothee
    Breit, Hanns-Christian
    EUROPEAN JOURNAL OF RADIOLOGY OPEN, 2024, 12
  • [29] Improved Resolution and Image Quality of Musculoskeletal Magnetic Resonance Imaging using Deep Learning-based Denoising Reconstruction: A Prospective Clinical Study
    Do, Hung P.
    Lockard, Carly A.
    Berkeley, Dawn
    Tymkiw, Brian
    Dulude, Nathan
    Tashman, Scott
    Gold, Garry
    Gross, Jordan
    Kelly, Erin
    Ho, Charles P.
    SKELETAL RADIOLOGY, 2024, 53 (12) : 2585 - 2596
  • [30] Deep Learning-Based Reconstruction Algorithm With Lung Enhancement Filter for Chest CT: Effect on Image Quality and Ground Glass Nodule Sharpness
    Hwang, Min-Hee
    Kang, Shinhyung
    Lee, Ji Won
    Lee, Geewon
    KOREAN JOURNAL OF RADIOLOGY, 2024, 25 (09) : 833 - 842