Analysis of human biological samples using porous graphitic carbon columns and liquid chromatography-mass spectrometry: a review

被引:2
|
作者
Rodrigues, Tais Betoni [1 ]
Cunha, Ricardo Leal [2 ]
Barci, Paulo Emilio Pereira [1 ]
Santos-Neto, alvaro Jose [1 ]
Lancas, Fernando Mauro [1 ]
机构
[1] Univ Sao Paulo, Sao Carlos Inst Chem, Lab Chromatog CROMA, BR-13560970 Sao Carlos, SP, Brazil
[2] Sci Police, Forens Toxicol Lab, BR-49100000 Sao Cristovao, SE, Brazil
基金
巴西圣保罗研究基金会;
关键词
Porous graphitic carbon columns; Polar retention effect on graphite; LC-MS; Human biological samples; Bioanalysis; EVAPORATIVE LIGHT-SCATTERING; SUPERCRITICAL-FLUID CHROMATOGRAPHY; HUMAN-MILK OLIGOSACCHARIDES; LC-ESI-MS; SUBSTITUTED PHENOL DERIVATIVES; PRINCIPAL COMPONENT ANALYSIS; UNDERIVATIZED AMINO-ACIDS; STATIONARY-PHASE; HIGH-TEMPERATURE; RETENTION BEHAVIOR;
D O I
10.1007/s00216-024-05458-8
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Liquid chromatography-mass spectrometry (LC-MS) has emerged as a powerful analytical technique for analyzing complex biological samples. Among various chromatographic stationary phases, porous graphitic carbon (PGC) columns have attracted significant attention due to their unique properties-such as the ability to separate both polar and non-polar compounds and their stability through all pH ranges and to high temperatures-besides the compatibility with LC-MS. This review discusses the applicability of PGC for SPE and separation in LC-MS-based analyses of human biological samples, highlighting the diverse applications of PGC-LC-MS in analyzing endogenous metabolites, pharmaceuticals, and biomarkers, such as glycans, proteins, oligosaccharides, sugar phosphates, and nucleotides. Additionally, the fundamental principles underlying PGC column chemistry and its advantages, challenges, and advances in method development are explored. This comprehensive review aims to provide researchers and practitioners with a valuable resource for understanding the capabilities and limitations of PGC columns in LC-MS-based analysis of human biological samples, thereby facilitating advancements in analytical methodologies and biomedical research.
引用
收藏
页码:5233 / 5253
页数:21
相关论文
共 50 条
  • [1] Analysis of human biological samples using porous graphitic carbon columns and liquid chromatography-mass spectrometry: a review (Vol 416, pg 5233, 2024)
    Rodrigues, Tais Betoni
    Cunha, Ricardo Leal
    Barci, Paulo Emilio Pereira
    Santos-Neto, alvaro Jose
    Lancas, Fernando Mauro
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2024, 416 (28) : 6691 - 6691
  • [2] In-House Packed Porous Graphitic Carbon Columns for Liquid Chromatography-Mass Spectrometry Analysis of N-Glycans
    Young, Clifford
    Condina, Mark R.
    Briggs, Matthew T.
    Moh, Edward S. X.
    Kaur, Gurjeet
    Oehler, Martin K.
    Hoffmann, Peter
    FRONTIERS IN CHEMISTRY, 2021, 9
  • [3] High temperature to increase throughput in liquid chromatography and liquid chromatography-mass spectrometry with a porous graphitic carbon stationary phase
    Pereira, Luisa
    Aspey, Stephen
    Ritchie, Harald
    JOURNAL OF SEPARATION SCIENCE, 2007, 30 (08) : 1115 - 1124
  • [4] Analysis of biological and synthetic ribonucleic acids by liquid chromatography-mass spectrometry using monolithic capillary columns
    Hölzl, G
    Oberacher, H
    Pitsch, S
    Stutz, A
    Huber, CG
    ANALYTICAL CHEMISTRY, 2005, 77 (02) : 673 - 680
  • [5] Advances in determination of vitamin D related compounds in biological samples using liquid chromatography-mass spectrometry: A review
    Higashi, Tatsuya
    Shimada, Kazutake
    Toyo'oka, Toshimasa
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2010, 878 (20): : 1654 - 1661
  • [6] Analysis of milk with liquid chromatography-mass spectrometry: a review
    Imperiale, Sebastian
    Morozova, Ksenia
    Ferrentino, Giovanna
    Scampicchio, Matteo
    EUROPEAN FOOD RESEARCH AND TECHNOLOGY, 2023, 249 (04) : 861 - 902
  • [7] Liquid chromatography on porous graphitic carbon with atmospheric pressure photoionization mass spectrometry and tandem mass spectrometry for the analysis of glycosphingolipids
    Roy, S.
    Delobel, A.
    Gaudin, K.
    Touboul, D.
    Germain, D. P.
    Baillet, A.
    Prognon, P.
    Laprevote, O.
    Chaminade, P.
    JOURNAL OF CHROMATOGRAPHY A, 2006, 1117 (02) : 154 - 162
  • [8] APPLICATION OF MICROBORE COLUMNS TO LIQUID CHROMATOGRAPHY-MASS SPECTROMETRY
    KRIEN, P
    DEVANT, G
    HARDY, M
    JOURNAL OF CHROMATOGRAPHY, 1982, 251 (02): : 129 - 139
  • [9] Analysis of polar metabolites in biological samples by ion-paring liquid chromatography-mass spectrometry
    Guo, Lili
    Worth, Andrew
    Mesaros, Clementina
    Blair, Ian
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2015, 250
  • [10] Hydrophilic Interaction Liquid Chromatography-Mass Spectrometry Characterization of Gangliosides in Biological Samples
    Hajek, Roman
    Jirasko, Robert
    Lisa, Miroslav
    Cifkova, Eva
    Holcapek, Michal
    ANALYTICAL CHEMISTRY, 2017, 89 (22) : 12425 - 12432