A Patch Wearable Cardioverter-Defibrillator for Patients at Risk of Sudden Cardiac Arrest

被引:2
|
作者
Hummel, John [1 ]
Houmsse, Mahmoud [1 ]
Tomassoni, Gery [2 ]
Nair, Devi [3 ]
Romero, Jorge [4 ,5 ]
Hargrove, Joe [3 ]
Mathews, Kiran [6 ]
Thakkar, Anjali B. [7 ]
Ullery, Steven [8 ]
Eapen, Zubin J. [6 ]
Kumar, Uday N. [6 ]
Mehran, Roxana [9 ]
Butler, Javed [10 ,11 ]
机构
[1] Ohio State Univ, Wexner Med Ctr, Columbus, OH USA
[2] Baptist Hlth Lexington, Lexington, KY USA
[3] St Bernards Heart & Vasc Ctr, Jonesboro, AR USA
[4] Harvard Med Sch, Brigham & Womens Hosp, Div Cardiovasc Med, Boston, MA USA
[5] Cardiol & Med Clin, Little Rock, AR USA
[6] Element Sci Inc, San Francisco, CA USA
[7] Univ Calif San Francisco, Dept Med, Div Cardiol, San Francisco, CA USA
[8] NAMSA, Minneapolis, MN USA
[9] Icahn Sch Med Mt Sinai, Zena & Michael A Wiener Cardiovasc Inst, New York, NY USA
[10] Baylor Scott & White Res Inst, 3434 Live Oak St, Dallas, TX 75204 USA
[11] Univ Mississippi, Dept Med, Jackson, MS USA
关键词
machine learning; sudden cardiac arrest; ventricular arrhythmia; wearable cardioverter defibrillator fi brillator; DEATH; PREVENTION; DISEASE;
D O I
10.1016/j.jacc.2024.04.063
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND For many patients, sudden cardiac arrest (SCA) risk is elevated temporarily. Wearable cardioverterdefibrillators (WCDs) can monitor and treat SCA during these temporary periods. Traditional WCDs can be uncomfortable, require frequent maintenance, and cannot be used when showering, resulting in poor compliance and avoidable SCA deaths. The Jewel is a novel, water-resistant patch-wearable cardioverter-defibrillator (P-WCD) with a machine learning detection algorithm designed to improve compliance and protection against SCA. OBJECTIVES This study aims to demonstrate the safety and clinical effectiveness of a novel P-WCD. METHODS The Jewel IDE Study, a prospective, single-arm study conducted at 30 U.S. sites, enrolled patients at SCA risk due to ventricular tachycardia/ventricular fibrillation who were not candidates for or refused an implantable defibrillator. The primary safety endpoint was <15% patients with clinically significant cutaneous adverse device effects and the primary effectiveness endpoint was <2 inappropriate shocks/100 patient-months. Secondary endpoints were >= 1 successful ventricular tachycardia/ventricular fibrillation conversion and wear time compliance of >14.1 h/d. RESULTS A total of 305 patients (mean age: 57.9 years; 30.2% female, 27.9% non-White) were enrolled, of which 290 had available device data. The clinically significant cutaneous adverse device effect rate was 2.30% (upper 1-sided 98% CI: 4.80); none were severe. No device-related deaths or serious adverse events were reported. The inappropriate shock rate was 0.36/100 patient-months (upper 1-sided 98% CI: 1.53). Of 11 shocks in 9 patients, 9 shocks were adjudicated to be appropriate. Eight of 9 shocks were successful with a single shock. Median wear time compliance was 23.5 (20.7-23.9) h/d. CONCLUSIONS The novel P-WCD is a safe and effective WCD with high patient compliance. There were no deaths due to noncompliance and a high number of successful conversions (Jewel IDE study [A Clinical Evaluation of the Jewel P-WCD in Subjects at High Risk for Sudden Cardiac Arrest]; NCT05201495) (J Am Coll Cardiol 2024;84:525-536) (c) 2024 The Authors. Published by Elsevier on behalf of the American College of Cardiology Foundation. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
引用
收藏
页码:525 / 536
页数:12
相关论文
共 50 条
  • [21] The impact of wearable cardioverter-defibrillator use on long-term decision for implantation of a cardioverter-defibrillator in a semirural acute care hospital
    Sinha, Anil-Martin
    Bense, Jens
    Hohenforst-Schmidt, Wolfgang
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2021, 62 (02) : 401 - 407
  • [22] Wearable cardioverter defibrillator for preventing sudden cardiac death in patients at risk: An updated systematic review of comparative effectiveness and safety
    Goetz, Gregor
    Wernly, Bernhard
    Wild, Claudia
    IJC HEART & VASCULATURE, 2023, 45
  • [23] Patients with a wearable cardioverter-defibrillator (WCD) Prescription, function and rehabilitation support
    Schlitt, A.
    Guha, M.
    Noutsias, M.
    Klein, H. H.
    Klein, H. U.
    HERZ, 2019, 44 (05) : 379 - 389
  • [24] Impact of Implantable Cardioverter-Defibrillator, Amiodarone, and Placebo on the Mode of Death in Stable Patients With Heart Failure Analysis From the Sudden Cardiac Death in Heart Failure Trial
    Packer, Douglas L.
    Prutkin, Jordan M.
    Hellkamp, Anne S.
    Mitchell, L. Brent
    Bernstein, Robert C.
    Wood, Freda
    Boehmer, John P.
    Carlson, Mark D.
    Frantz, Robert P.
    McNulty, Steve E.
    Rogers, Joseph G.
    Anderson, Jill
    Johnson, George W.
    Walsh, Mary Norine
    Poole, Jeanne E.
    Mark, Daniel B.
    Lee, Kerry L.
    Bardy, Gust H.
    CIRCULATION, 2009, 120 (22) : 2170 - 2176
  • [25] Potential cost-effectiveness of wearable cardioverter-defibrillator for patients with implantable cardioverter-defibrillator explant in a high-income city of China
    Jiang, Xinchan
    Ming, Wai-Kit
    You, Joyce H. S.
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2019, 30 (11) : 2387 - 2396
  • [26] The wearable cardioverter/defibrillator. Temporary protection from sudden cardiac death
    Duncker, D.
    Bauersachs, J.
    Veltmann, C.
    INTERNIST, 2016, 57 (09): : 864 - 870
  • [27] INFLUENCE OF THE IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR ON SUDDEN-DEATH AND TOTAL MORTALITY IN PATIENTS EVALUATED FOR CARDIAC TRANSPLANTATION
    SWEENEY, MO
    RUSKIN, JN
    GARAN, H
    MCGOVERN, BA
    GUY, ML
    TORCHIANA, DF
    VLAHAKES, GJ
    NEWELL, JB
    SEMIGRAN, MJ
    DEC, GW
    CIRCULATION, 1995, 92 (11) : 3273 - 3281
  • [28] Shocks burden and increased mortality in implantable cardioverter-defibrillator patients
    Larsen, Gail K.
    Evans, John
    Lambert, William E.
    Chen, Yiyi
    Raitt, Merritt H.
    HEART RHYTHM, 2011, 8 (12) : 1881 - 1886
  • [29] Wearable Cardioverter-Defibrillator Use in Patients Perceived to Be at High Risk Early Post-Myocardial Infarction
    Epstein, Andrew E.
    Abraham, William T.
    Bianco, Nicole R.
    Kern, Karl B.
    Mirro, Michael
    Rao, Sunil V.
    Rhee, Edward K.
    Solomon, Scott D.
    Szymkiewicz, Steven J.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2013, 62 (21) : 2000 - 2007
  • [30] Extended Use of the Wearable Cardioverter-Defibrillator: Which Patients Are Most Likely to Benefit?
    Kovacs, Boldizsar
    Reek, Sven
    Krasniqi, Nazmi
    Eriksson, Urs
    Duru, Firat
    CARDIOLOGY RESEARCH AND PRACTICE, 2018, 2018