Continuous glucose monitoring in pregnancies with type 1 diabetes: small increases in time-in-range improve maternal and perinatal outcomes

被引:8
作者
Sobhani, Nasim C. [1 ]
Goemans, Sophie [2 ]
Nguyen, Antoinette [3 ]
Chambers, Melissa E. [6 ]
Richley, Michael [4 ]
Gabby, Lauryn C. [2 ]
Field, Nancy [5 ]
Han, Christina S. [4 ]
Ramos, Gladys A. [2 ]
机构
[1] Univ Calif San Francisco, Dept Obstet Gynecol & Reprod Sci, Div Maternal Fetal Med, San Francisco, CA 94115 USA
[2] Univ Calif San Diego, Dept Obstet Gynecol & Reprod Sci, Div Maternal Fetal Med, San Diego, CA USA
[3] Univ Rochester, Sch Med & Dent, Rochester, NY USA
[4] Univ Calif Los Angeles, Dept Obstet & Gynecol, Div Maternal Fetal Med, Los Angeles, CA USA
[5] Univ Calif Davis, Dept Obstet & Gynecol, Div Maternal Fetal Med, Davis, CA USA
[6] Univ Calif Irvine, Dept Obstet & Gynecol, Div Maternal Fetal Med, Irvine, CA USA
关键词
diabetes in pregnancy; diabetes technology; glycemic control; hyperglycemia in pregnancy; WOMEN; MANAGEMENT;
D O I
10.1016/j.ajog.2024.01.010
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Background: Continuous glucose monitors provide detailed information regarding glycemic control in pregnant patients with type 1 diabetes. Little data have been published examining the association between continuous glucose monitor parameters and perinatal outcomes among gravidas with type 1 diabetes using continuous glucose monitors. Objective: This study aimed to examine the association between perinatal outcomes and time-in-range as assessed by continuous glucose monitors used in pregnant individuals with type 1 diabetes. We hypothesized that higher time-in-range would be associated with lower risk of adverse perinatal outcomes. Study design: This multicenter retrospective cohort study included all gravidas with type 1 diabetes using continuous glucose monitors who delivered from 2020 to 2022 at 5 University of California sites. Only those with continuous glucose monitor target range set to 70 to 140 mg/dL (+/- 10 mg/dL) were included. Time-in-range (%) was recorded at 12, 16, 20, 24, 28, and 32 weeks. The primary maternal and neonatal outcomes were preeclampsia and large for gestational age, defined as birthweight >= 95th percentile. Kruskal-Wallis tests were used to compare median time-in-range between those with and without the primary outcomes. Log-binomial regression was used to obtain risk ratios, with adjustment for microvascular disease and years with type 1 diabetes. Results: A total of 91 patients were included. Most used an insulin pump (81%) and did not have diabetic microvascular disease (72%). Median time since diagnosis of type 1 diabetes was 16 years, and median periconception hemoglobin A1c was 6.7%. Compared with those with preeclampsia, normotensive gravidas had significantly higher time-in-range at nearly every time point. A similar pattern was observed for those with normal-birthweight infants compared with large-for-gestational-age infants. On adjusted analyses, every 5-unit increase in time-in-range at 12 weeks was associated with 45% and 46% reductions in the risks of preeclampsia and large for gestational age, respectively (preeclampsia: adjusted risk ratio, 0.55; 95% confidence interval, 0.30-0.99; large for gestational age: adjusted risk ratio, 0.54; 95% confidence interval, 0.29-0.99). Conclusion: Higher time-in-range is associated with lower risk of preeclampsia and large for gestational age. This association is observed early in gestation, when each 5-unit increase in time-in-range is associated with similar to 50% reduction in the risk of these complications. These findings can be used to counsel patients regarding the risk of pregnancy complications at specific time-in-range values, and to encourage patients that even small improvements in time-in-range can have significant impact on pregnancy outcomes. Larger studies are needed to further explore these findings and to identify optimal time-in-range to reduce perinatal complication rates.
引用
收藏
页码:467e1 / 467e8
页数:8
相关论文
共 50 条
  • [1] Clinical Effectiveness of Continuous Glucose Monitoring in Pregnancies Affected by Type 1 Diabetes
    Gao, Valerie
    Snell-Bergeon, Janet K.
    Malecha, Emily
    Johnson, Carly A.
    Polsky, Sarit
    DIABETES TECHNOLOGY & THERAPEUTICS, 2024, 26 (08) : 526 - 535
  • [2] Continuous glucose monitoring in type 1 diabetes
    Mauras, Nelly
    Fox, Larry
    Englert, Kimberly
    Beck, Roy W.
    ENDOCRINE, 2013, 43 (01) : 41 - 50
  • [3] Relationship Between Time-in-Range, HbA1c, and the Glucose Management Indicator in Pregnancies Complicated by Type 1 Diabetes
    Shah, Viral N.
    Snell-Bergeon, Janet K.
    Demmitt, Jamie K.
    Joshee, Prakriti
    Garcetti, Rachel
    Pyle, Laura
    Polsky, Sarit
    DIABETES TECHNOLOGY & THERAPEUTICS, 2021, 23 (12) : 783 - 790
  • [4] Continuous Glucose Monitoring-Derived Differences in Pregnancies With and Without Adverse Perinatal Outcomes
    Durnwald, Celeste
    Beck, Roy W.
    Li, Zoey
    Norton, Elizabeth
    Bergenstal, Richard
    Johnson, Mary
    Dunnigan, Sean
    Banfield, Matthew
    Krumwiede, Katie
    Sibayan, Judy
    Calhoun, Peter
    Carlson, Anders L.
    OBSTETRICS AND GYNECOLOGY, 2024, 144 (05) : 684 - 696
  • [5] Continuous Glucose Monitoring and Time in Range: Association with Adverse Outcomes among People with Type 2 or Gestational Diabetes Mellitus
    Bitar, Ghamar
    Cornthwaite, Joycelyn A.
    Sadek, Sandra
    Ghorayeb, Tala
    Daye, Nahla
    Nazeer, Sarah
    Ghafir, Danna
    Cornthwaite, John
    Chauhan, Suneet P.
    Sibai, Baha M.
    Bartal, Michal Fishel
    AMERICAN JOURNAL OF PERINATOLOGY, 2024, 41 : e1370 - e1377
  • [6] Time in Range and Pregnancy Outcomes in People with Diabetes Using Continuous Glucose Monitoring
    Bartal, Michal Fishel
    Cornthwaite, Joycelyn A. Ashby A.
    Ghafir, Danna
    Ward, Clara
    Ortiz, Gladys
    Louis, Aleaha
    Cornthwaite, John
    Chauhan, Suneet S. P.
    Sibai, Baha M.
    AMERICAN JOURNAL OF PERINATOLOGY, 2023, 40 (05) : 461 - 466
  • [7] Satisfaction with continuous glucose monitoring is positively correlated with time in range in children with type 1 diabetes
    Marigliano, Marco
    Pertile, Riccardo
    Mozzillo, Enza
    Troncone, Alda
    Maffeis, Claudio
    Morotti, Elisa
    Di Candia, Francesca
    Fedi, Ludovica
    Iafusco, Dario
    Zanfardino, Angela
    Cauvin, Vittoria
    Maltoni, Giulio
    Zucchini, Stefano
    Cherubini, Valentino
    Tiberi, Valentina
    Minuto, Nicola
    Bassi, Marta
    Rabbone, Ivana
    Savastio, Silvia
    Tinti, Davide
    Tornese, Gianluca
    Schiaffini, Riccardo
    Passanisi, Stefano
    Lombardo, Fortunato
    Bonfanti, Riccardo
    Scaramuzza, Andrea
    Franceschi, Roberto
    DIABETES RESEARCH AND CLINICAL PRACTICE, 2023, 204
  • [8] Maternal and perinatal outcomes in pregnant women with type 1 diabetes treated with continuous subcutaneous insulin infusion and real time continuous glucose monitoring in two specialized centers in Medellin, Colombia
    Restrepo-Moreno, Monica
    Ramirez-Rincon, Alex
    Hincapie-Garcia, Jaime
    Palacio, Andres
    Monsalve-Arango, Claudia
    Aristizabal-Henao, Natalia
    Restrepo-Zapata, Camila
    Fernando Botero-Arango, Jose
    JOURNAL OF MATERNAL-FETAL & NEONATAL MEDICINE, 2018, 31 (06) : 696 - 700
  • [9] A Feasibility Study of Paired Continuous Glucose Monitoring Intrapartum and in the Newborn in Pregnancies Complicated by Type 1 Diabetes
    Stewart, Zoe A.
    Thomson, Lynn
    Murphy, Helen R.
    Beardsall, Kathryn
    DIABETES TECHNOLOGY & THERAPEUTICS, 2019, 21 (01) : 20 - 27
  • [10] Perinatal outcomes in pregnancies complicated by type 1 diabetes mellitus
    Xu, Qianyue
    Lu, Jing
    Hu, Jun
    Ge, Zhijuan
    Zhu, Dalong
    Bi, Yan
    GYNECOLOGICAL ENDOCRINOLOGY, 2020, 36 (10) : 879 - 884