Quantitative Spermidine Detection in Cosmetics using an Organic Transistor-based Chemical Sensor

被引:0
作者
Sasaki, Yui [1 ,2 ]
Ohshiro, Kohei [1 ]
Kato, Miyuki [1 ]
Tanaka, Hikaru [3 ]
Yamagami, Akari [3 ]
Hagiya, Kazutake [3 ]
Minami, Tsuyoshi [1 ]
机构
[1] Univ Tokyo, Inst Ind Sci, 4-6-1 Komaba,Meguro Ku, Tokyo 1538505, Japan
[2] JST, PRESTO, 4-1-8 Honcho, Kawaguchi, Saitama 3320012, Japan
[3] Toyobo Co Ltd, Corp Res Ctr, 2-1-1 Katata, Otsu, Shiga 5200292, Japan
来源
CHEMISTRYOPEN | 2024年 / 13卷 / 10期
基金
日本学术振兴会;
关键词
Sensors; Amines; Organic transistor; Cosmetic analysis; FIELD-EFFECT TRANSISTOR; LABEL-FREE; POLYAMINES; BIOSENSORS; POLYMERS; PROTEIN;
D O I
10.1002/open.202400098
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Spermidine is an essential biomarker related to antiaging. Although the detection of spermidine levels is in high demand in life science fields, easy-to-use analytical tools without sample purification have not yet been fully established. Herein, we propose an organic field-effect transistor-based chemical sensor for quantifying the spermidine concentration in commercial cosmetics. An extended-gate structure was employed for organic field-effect transistor (OFET)-based chemical sensing in aqueous media. A coordination-bond-based sensing system was introduced into the OFET device to visualize the spermidine detection information through changes in the transistor characteristics. The extended-gate-type OFET has shown quantitative responses to spermidine, which indicates sufficient detectability (i. e., the limit of detection for spermidine: 2.3 mu M) considering actual concentrations in cosmetics. The applicability of the OFET-based chemical sensor for cosmetic analysis was validated by instrumental analysis using high-performance liquid chromatography. The estimated recovery rates for spermidine in cosmetic ingredient products (108-111 %) suggest the feasibility of cosmetic analysis based on the OFET-based chemical sensor. An extended-gate-type organic transistor can be used to quantify spermidine levels in cosmetic ingredient products without complicated sample purification. The accurate detection results, validated by HPLC, indicate the potential of organic transistors as platforms for cosmetic analysis. image
引用
收藏
页数:4
相关论文
共 41 条
  • [1] Detection of polyamines by an extended gate-type organic transistor functionalized with a carboxylate attached 1,3,4-thiadiazole derivative
    Asano, Koichiro
    Sasaki, Yui
    Zhou, Qi
    Mitobe, Riho
    Tang, Wei
    Lyu, Xiaojun
    Kamiko, Masao
    Tanaka, Hikaru
    Yamagami, Akari
    Hagiya, Kazutake
    Minami, Tsuyoshi
    [J]. JOURNAL OF MATERIALS CHEMISTRY C, 2021, 9 (35) : 11690 - 11697
  • [2] 7 MEMBERED CHELATE RINGS IN COPPER(II) COMPLEXES WITH SPERMIDINE
    BARBUCCI, R
    CAMPBELL, MJM
    CANNAS, M
    MARONGIU, G
    [J]. INORGANICA CHIMICA ACTA-BIOINORGANIC CHEMISTRY, 1980, 46 (03): : 135 - 138
  • [3] Polyamine metabolism and cancer: treatments, challenges and opportunities
    Casero, Robert A., Jr.
    Stewart, Tracy Murray
    Pegg, Anthony E.
    [J]. NATURE REVIEWS CANCER, 2018, 18 (11) : 681 - 695
  • [4] Antioxidant and antimelanogenic activities of polyamine conjugates from corn bran and related hydroxycinnamic acids
    Choi, Sang Won
    Lee, Sung Kwon
    Kim, Eun Ok
    Oh, Ji Hae
    Yoon, Kyung Sup
    Parris, Nicholas
    Hicks, Kevin B.
    Moreau, Robert A.
    [J]. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2007, 55 (10) : 3920 - 3925
  • [5] Recent Progress in Inkjet-Printed Thin-Film Transistors
    Chung, Seungjun
    Cho, Kyungjune
    Lee, Takhee
    [J]. ADVANCED SCIENCE, 2019, 6 (06)
  • [6] Surface Modification with Control over Ligand Density for the Study of Multivalent Biological Systems
    Di Iorio, Daniele
    Huskens, Jurriaan
    [J]. CHEMISTRYOPEN, 2020, 9 (01): : 53 - 66
  • [7] Non-enzymatic detection of glucose levels in human blood plasma by a graphene oxide-modified organic transistor sensor
    Fan, Haonan
    Sasaki, Yui
    Zhou, Qi
    Tang, Wei
    Nishina, Yuta
    Minami, Tsuyoshi
    [J]. CHEMICAL COMMUNICATIONS, 2023, 59 (17) : 2425 - 2428
  • [8] Printed Organic Transistors with Uniform Electrical Performance and Their Application to Amplifiers in Biosensors
    Fukuda, Kenjiro
    Minamiki, Tsukuru
    Minami, Tsuyoshi
    Watanabe, Makoto
    Fukuda, Takashi
    Kumaki, Daisuke
    Tokito, Shizuo
    [J]. ADVANCED ELECTRONIC MATERIALS, 2015, 1 (07):
  • [9] Effects of the alkyl chain length in phosphonic acid self-assembled monolayer gate dielectrics on the performance and stability of low-voltage organic thin-film transistors
    Fukuda, Kenjiro
    Hamamoto, Takanori
    Yokota, Tomoyuki
    Sekitani, Tsuyoshi
    Zschieschang, Ute
    Klauk, Hagen
    Someya, Takao
    [J]. APPLIED PHYSICS LETTERS, 2009, 95 (20)
  • [10] Interaction of thiadiazole additives with metal surfaces:: Reactions and thin-film formation on gold as a model surface
    Hipler, F
    Girol, SG
    Azzam, W
    Fischer, RA
    Wöll, C
    [J]. LANGMUIR, 2003, 19 (15) : 6072 - 6080