Comparative evaluation of the effects of laser and chemical denture disinfectants on the surface characteristics of CAD-CAM and conventional denture resins: An in vitro experimental study

被引:0
作者
Moussa, Rania [1 ]
Ellakany, Passent [2 ]
Fouda, Shaimaa M. [2 ]
El-Din, Mai Salah [3 ]
机构
[1] Taibah Univ, Coll Dent, Dept Substitut Dent Sci, Al Madinah Al Munawwarah, Saudi Arabia
[2] Imam Abdulrahman Bin Faisal Univ, Coll Dent, Dept Substitut Dent Sci, Dammam, Saudi Arabia
[3] Alexandria Univ Main Hosp, Dept Prosthodont, Alexandria, Egypt
来源
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY | 2024年
关键词
CAD-CAM; denture cleansers; laser; PMMA; surface properties; MECHANICAL-PROPERTIES; DIODE-LASER; CLEANSERS; POLYAMIDE; PMMA;
D O I
10.1111/jopr.13952
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: The purpose of this study was to assess the effect of Ga-Al-Ar diode, Nd:YAG lasers, and chemical disinfectants (NaOCl, vinegar, and Corega) on surface roughness (Ra) and hardness (VHN) of polymethylmethacrylate (PMMA), thermoplastic polyamide, milled and 3D-printed denture base resins. Materials and Methods: About 432 specimens of PMMA, thermoplastic polyamide, milled, and 3D-printed resins were divided into six subgroups (n = 18): distilled water (control:C), Ga-Al-Ar diode laser (L1), Nd:YAG laser (L2), 1% sodium hypochlorite (NaOCl), vinegar (AA), and Corega (CR). Each specimen's Ra and VHN were measured. Surface topography assessment was done using scanning electron microscopy (SEM). Analysis was done using ANOVA and post hoc Tukey's test (p = 0.05). Results: A significant difference was noted in Ra and VHN as affected by denture base materials, surface disinfectants, and their interaction (p < 0.001). Results showed a significant increase in Ra of PMMA with NaOCL (p < 0.001), AA (p = 0.005), and CR (p = 0.009), thermoplastic polyamide with L1 (p = 0.012), L2 (p = 0.015), NaOCL AA, and CR (p < 0.001 each), milled resin with AA NaOCL, and CR (p < 0.001 each), and 3D-printed resin with L1, NaOCl, AA (p < 0.001 each), and CR (p = 0.008). The VHN increased in PMMA with NaOCL (p < 0.001), AA (p = 0.044), and CR (p < 0.001), thermoplastic polyamide with L1 (p = 0.037), milled resin with L1, L2, and CR (p < 0.001 each), and 3D-printed resin with L1, NaOCl (p < 0.001 each), and decreased with CR (p = 0.007). Conclusion: The tested properties showed variations affected by denture base material and surface disinfectants. Laser treatments induced smoother surfaces than chemical disinfectants. Laser improved the surface hardness of CAD-CAM resins, while chemical immersion improved that of PMMA.
引用
收藏
页数:9
相关论文
共 37 条
[1]  
ahin Z., 2022, Turkiye Klin J Dent Sci, V28, P139, DOI [10.5336/dentalsci.2021-83103, DOI 10.5336/DENTALSCI.2021-83103]
[2]   A Comparison of the Surface and Mechanical Properties of 3D Printable Denture-Base Resin Material and Conventional Polymethylmethacrylate (PMMA) [J].
Al-Dwairi, Ziad N. ;
Ebrahim, Abdulkareem A. Al Haj ;
Baba, Nadim Z. .
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2023, 32 (01) :40-48
[3]   Impact of Denture Cleansing Solution Immersion on Some Properties of Different Denture Base Materials: An In Vitro Study [J].
Al-Thobity, Ahmad M. ;
Gad, Mohammed ;
ArRejaie, Aws ;
Alnassar, Talal ;
Al-Khalifa, Khalifa S. .
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2019, 28 (08) :913-919
[4]   Efficacy of Denture Cleansers on Microbial Adherence and Surface Topography of Conventional and CAD/CAM-Processed Denture Base Resins [J].
Alfouzan, Afnan F. ;
Tuwaym, Malath ;
Aldaghri, Ebtihal N. ;
Alojaymi, Tagreed ;
Alotiabi, Hadeel Minife ;
Taweel, Sara M. Al ;
Al-Otaibi, Hanan N. ;
Ali, Rizwan ;
Alshehri, Huda ;
Labban, Nawaf .
POLYMERS, 2023, 15 (02)
[5]   Disinfection efficacy and fracture strength of PMMA denture-based polymer with chlorhexidine, PDT utilizing Rose Bengal and hematoporphyrin, and Er, Cr: YSGG laser [J].
AlHelal, Abdulaziz A. .
PHOTODIAGNOSIS AND PHOTODYNAMIC THERAPY, 2022, 37
[6]  
Alkaltham NS., 2023, Effect of denture disinfectants on the mechanical performance of 3Dprinted denture base materials. Polymers (Basel), V15, P1, DOI [10.3390/polym15051175, DOI 10.3390/POLYM15051175]
[7]  
Aly MD., 2021, Egypt Dent J, V67, P2431, DOI [10.21608/edj.2021.71985.1584, DOI 10.21608/EDJ.2021.71985.1584]
[8]   In Vitro Evaluation of Candida albicans Adhesion and Related Surface Properties of CAD/CAM Denture Base Resins [J].
不详 .
EUROPEAN JOURNAL OF DENTISTRY, 2024, 18 (02) :579-586
[9]  
[Anonymous], Power and Sample size.com Calculators
[10]  
Arruda Carolina Noronha Ferraz, 2015, Braz. Dent. J., V26, P404, DOI 10.1590/0103-6440201300120