Nanofractionation Analytics for Comparing MALDI-MS and ESI-MS Data of Viperidae Snake Venom Toxins

被引:1
|
作者
Xu, Haifeng [1 ,2 ]
Mastenbroek, Jesse [1 ]
Krikke, Natascha T. B. [1 ]
El-Asal, Susan [1 ]
Mutlaq, Rama [1 ]
Casewell, Nicholas R. [3 ]
Slagboom, Julien [1 ,2 ]
Kool, Jeroen [1 ,2 ]
机构
[1] Vrije Univ Amsterdam, Amsterdam Inst Mol & Life Sci, Div Bioanalyt Chem, Dept Chem & Pharmaceut Sci,Fac Sci, Boelelaan 1085, NL-1081 HV Amsterdam, Netherlands
[2] Ctr Analyt Sci Amsterdam CASA, NL-1012 WX Amsterdam, Netherlands
[3] Univ Liverpool Liverpool Sch Trop Med, Ctr Snakebite Res & Intervent, Liverpool L3 5QA, England
关键词
viperid venoms; ESI-MS; MALDI-MS; intact MS comparison; plasma coagulation; MASS-SPECTROMETRY; KING COBRA; IDENTIFICATION; RATTLESNAKE; EXPRESSION; SCORPION; PROTEINS; PROTEOME; TOOLS;
D O I
10.3390/toxins16080370
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
Worldwide, it is estimated that there are 1.8 to 2.7 million cases of envenoming caused by snakebites. Snake venom is a complex mixture of protein toxins, lipids, small molecules, and salts, with the proteins typically responsible for causing pathology in snakebite victims. For their chemical characterization and identification, analytical methods are required. Reversed-phase liquid chromatography coupled with electrospray ionization mass spectrometry (RP-LC-ESI-MS) is a widely used technique due to its ease of use, sensitivity, and ability to be directly coupled after LC separation. This method allows for the efficient separation of complex mixtures and sensitive detection of analytes. On the other hand, matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) is also sometimes used, and though it typically requires additional sample preparation steps, it offers desirable suitability for the analysis of larger biomolecules. In this study, seven medically important viperid snake venoms were separated into their respective venom toxins and measured by ESI-MS. In parallel, using nanofractionation analytics, post-column high-resolution fractionation was used to collect the eluting toxins for further processing for MALDI-MS analysis. Our comparative results showed that the deconvoluted snake venom toxin masses were observed with good sensitivity from both ESI-MS and MALDI-MS approaches and presented overlap in the toxin masses recovered (between 25% and 57%, depending on the venom analyzed). The mass range of the toxins detected in high abundance was between 4 and 28 kDa. In total, 39 masses were found in both the ESI-MS and/or MALDI-MS analyses, with most being between 5 and 9 kDa (46%), 13 and 15 kDa (38%), and 24 and 28 kDa (13%) in size. Next to the post-column MS analyses, additional coagulation bioassaying was performed to demonstrate the parallel post-column assessment of venom activity in the workflow. Most nanofractionated venoms exhibited anticoagulant activity, with three venoms additionally exhibiting toxins with clear procoagulant activity (Bothrops asper, Crotalus atrox, and Daboia russelii) observed post-column. The results of this study highlight the complementarity of ESI-MS and MALDI-MS approaches for characterizing snake venom toxins and provide a complementary overview of defined toxin masses found in a diversity of viper snake venoms.
引用
收藏
页数:19
相关论文
共 50 条
  • [11] Development of a versatile method for the analysis of glycoproteins using monolithic capillary LC coupled to ESI-MS and MALDI-MS
    Dragan, I
    Swart, R
    van Ling, R
    Chervet, JP
    LC GC EUROPE, 2004, 17 (11A) : 40 - 42
  • [12] ESI-MS and MALDI-MS analysis, and amino acid sequencing of three multiple-antigen peptides (MAPs)
    Becklin, RR
    Desiderio, DM
    PEPTIDES: FRONTIERS OF PEPTIDES SCIENCE, 1999, : 809 - 810
  • [13] Multifaceted Investigation of Metabolites During Nitrogen Fixation in Medicago via High Resolution MALDI-MS Imaging and ESI-MS
    Gemperline, Erin
    Jayaraman, Dhileepkumar
    Maeda, Junko
    Ane, Jean-Michel
    Li, Lingjun
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2015, 26 (01) : 149 - 158
  • [14] A combined ESI- and MALDI-MS(/MS) study of peripherally persulfonylated dendrimers: False negative results by MALDI-MS and analysis of defects
    Felder, T
    Schalley, CA
    Fakhrnabavi, H
    Lukin, O
    CHEMISTRY-A EUROPEAN JOURNAL, 2005, 11 (19) : 5625 - 5636
  • [15] MALDI-MS and HILIC ESI-MS/MS as Versatile Tools for Detection of Monoethanolamine Degradation Products in a Real Postcombustion Carbon Dioxide Capture Plant
    Cotugno, P.
    Monopoli, A.
    Nacci, A.
    Zambonin, C. G.
    Calvano, C. D.
    ENERGY & FUELS, 2014, 28 (02) : 1295 - 1303
  • [16] Investigation of the interaction of iron(III) complexes with dAMP by ESI-MS, MALDI-MS and potentiometric titration: insights into synthetic nuclease behavior
    Fernandes, Christiane
    Moreira, Rafaela Oliveira
    Lube, Leonardo M.
    Horn, Adolfo, Jr.
    Szpoganicz, Bruno
    Sherrod, Stacy
    Russell, David H.
    DALTON TRANSACTIONS, 2010, 39 (21) : 5094 - 5100
  • [17] Antivenom Neutralization of Coagulopathic Snake Venom Toxins Assessed by Bioactivity Profiling Using Nanofractionation Analytics
    Xie, Chunfang
    Slagboom, Julien
    Albulescu, Laura-Oana
    Bruyneel, Ben
    Still, Kristina B. M.
    Vonk, Freek J.
    Somsen, Govert W.
    Casewell, Nicholas R.
    Kool, Jeroen
    TOXINS, 2020, 12 (01)
  • [18] ESI- and MALDI-MS of aluminum peptides and proteins.
    Limbach, PA
    Ragas, JA
    Patrick, C
    Griggs, ME
    Bailey, M
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2001, 221 : U79 - U79
  • [19] Comparison of feature selection and classification for MALDI-MS data
    Qingzhong Liu
    Andrew H Sung
    Mengyu Qiao
    Zhongxue Chen
    Jack Y Yang
    Mary Qu Yang
    Xudong Huang
    Youping Deng
    BMC Genomics, 10
  • [20] Comparison of feature selection and classification for MALDI-MS data
    Liu, Qingzhong
    Sung, Andrew H.
    Qiao, Mengyu
    Chen, Zhongxue
    Yang, Jack Y.
    Yang, Mary Qu
    Huang, Xudong
    Deng, Youping
    BMC GENOMICS, 2009, 10