Intra-rater and Inter-rater Reliability of the Commander Pressure Algometer in Greek Patients With Chronic Neck Pain

被引:0
|
作者
Skordis, Charalampos [1 ]
Liaskou, Christina [1 ]
Papagiakoumou, Evangelia [1 ]
Sotiropoulos, Spyridon [1 ]
Plavoukou, Theodora [1 ]
Karakasidou, Palina [1 ]
Georgoudis, George [1 ]
机构
[1] Univ West Attica UNIWA, Physiotherapy Dept, Athens, Greece
关键词
commander; non-specific chronic neck pain; greek patients; inter-rater reliability; intra-rater reliability; pressure algometer; pressure pain threshold (ppt); SHORT-FORM; THRESHOLD; REPEATABILITY; INDIVIDUALS; SENSITIVITY; ASSOCIATION; VALIDITY; MUSCLES; PEOPLE;
D O I
10.7759/cureus.66350
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction Non-specific chronic neck pain (NSCNP) is a musculoskeletal disorder that affects 45%-54% of the general population. There is a strong correlation between patient-reported pain and mechanical pain pressure threshold (PPT) measured with an algometer. Purpose This study aims to investigate the intra- and inter-rater reliability of the Commander algometer in Greek NSCNP patients, in an urban primary care setting. Methods Thirty-three patients (22 women and 11 men) suffering from NSCNP (>3 months), the majority (42.4%) between the ages of 50 years and 59 years and overweight, were measured bilaterally both at the neck (mastoid, trapezius head-insertion and mid-portion, C5-C6 facet, insertion of levator scapula) and at the control areas (mid-deltoid and tibialis anterior) using the Commander algometer. Measurements were taken twice over a span of six days, by two raters, in a primary care setting. Intraclass correlation coefficient (ICC) statistics were used as measures of reliability (p = 0.05). Results Intra-rater reliability was "moderate to good" for both raters. ICC values for PPT at the seven bilaterally measured sites varied between 0.67 and 0.86 for the first rater (p < 0.001) and 0.64 and 0.82 for the second rater (p < 0.003). The inter-rater reliability was "moderate to excellent" (ICC = 0.68-0.92) in the first measurement (T1) and "moderate to good" (ICC = 0.68 to 0.89) in the second measurement (T2). Conclusion This study supports the intra- and inter-rater reliability of the Commander algometer in detecting reliably the mechanical PPT, in Greek NSCNP patients, as measured according to the procedures and methodology followed throughout this study.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] Inter-Rater Reliability of Kampo Diagnosis for Chronic Diseases
    Maeda-Minami, Ayako
    Yoshino, Tetsuhiro
    Horiba, Yuko
    Nakamura, Tomonori
    Watanabe, Kenji
    JOURNAL OF ALTERNATIVE AND COMPLEMENTARY MEDICINE, 2021, 27 (07) : 613 - 616
  • [42] Inter-Rater and Intra-Rater Reliability of the INSPECT (Interactive Nutrition Specific Physical Exam Competency Tool) Measured in Multi-Site Acute Care Settings
    Zechariah, Sunitha
    Waller, Jennifer L.
    Stallings, Judith
    Gess, Ashley J.
    Lehman, Leigh
    HEALTHCARE, 2022, 10 (02)
  • [43] Intra-rater and inter-rater reliability of the process of obtaining cross-sectional area and echo intensity measurements of muscles from ultrasound images
    Sobolewski, Eric J.
    Wein, Leah D.
    Crow, Jacquelyn M.
    Carpenter, Kaitlyn M.
    JOURNAL OF ULTRASONOGRAPHY, 2021, 21 (84) : E7 - E11
  • [44] The behavior flexibility rating scale-revised (BFRS-R): Factor analysis, internal consistency, inter-rater and intra-rater reliability, and convergent validity
    Peters-Scheffer, Nienke
    Didden, Robert
    Green, Vanessa A.
    Sigafoos, Jeff
    Korzilius, Hubert
    Pituch, Keenan
    O'Reilly, Mark F.
    Lancioni, Giulio
    RESEARCH IN DEVELOPMENTAL DISABILITIES, 2008, 29 (05) : 398 - 407
  • [45] Inter-rater reliability of pressure biofeedback unit among individuals with and without chronic low back pain
    Khan, Muhammad
    Zafar, Hamayun
    Gilani, Syed Amir
    PAKISTAN JOURNAL OF MEDICAL SCIENCES, 2022, 38 (04) : 987 - 991
  • [46] Inter-rater and intra-rater reliability of belt-stabilized hand-held dynamometer using make test in lower extremity muscle strength assessment among healthy adults
    Espino, Reil Vinard S.
    Gonzalez-Suarez, Consuelo
    Ingram, Lewis A.
    Gomez, Ivan Neil B.
    Agarao, Kris Anthony T.
    Flores, Jazzmine Gale
    Bulseco, Nicole
    INTERNATIONAL JOURNAL OF OSTEOPATHIC MEDICINE, 2025, 56
  • [47] Three-dimensional kinematics of shoulder function in stroke patients: Inter- and intra-rater reliability
    Hansen, Gunhild M.
    Kersting, Uwe G.
    Pedersen, Asger R.
    Svendsen, Susanne W.
    Nielsen, Jorgen F.
    JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2019, 47 : 35 - 42
  • [48] Intra- and Inter-Rater Reliability of the Modified Tuck Jump Assessment
    Fort-Vanmeerhaeghe, Azahara
    Montalvo, Alicia M.
    Lloyd, Rhodri S.
    Read, Paul
    Myer, Gregory D.
    JOURNAL OF SPORTS SCIENCE AND MEDICINE, 2017, 16 (01) : 117 - 124
  • [49] Intra and Inter-Rater Reliability of Ultrasound in Plantar Fascia Thickness Measurement
    Nakhaee, Masoomeh
    Mousavi, Mohammad Ebrahim
    Mohseni-Bandpei, Mohammad Ali
    Shakourirad, Ali
    Safari, Mohammad Reza
    Kashani, Reza Vahab
    Baneshi, Mohammad Reza
    Nakhaei, Masoud
    IRANIAN JOURNAL OF RADIOLOGY, 2018, 15 (03)
  • [50] Inter- and Intra-rater Reliability in Lithic Analysis: a Case Study in Handedness Determination Methodologies
    Lana Ruck
    Chloe Holden
    Shelby S. J. Putt
    Kathy Schick
    Nicholas Toth
    Journal of Archaeological Method and Theory, 2020, 27 : 220 - 244