Intra-rater and Inter-rater Reliability of the Commander Pressure Algometer in Greek Patients With Chronic Neck Pain

被引:0
|
作者
Skordis, Charalampos [1 ]
Liaskou, Christina [1 ]
Papagiakoumou, Evangelia [1 ]
Sotiropoulos, Spyridon [1 ]
Plavoukou, Theodora [1 ]
Karakasidou, Palina [1 ]
Georgoudis, George [1 ]
机构
[1] Univ West Attica UNIWA, Physiotherapy Dept, Athens, Greece
关键词
commander; non-specific chronic neck pain; greek patients; inter-rater reliability; intra-rater reliability; pressure algometer; pressure pain threshold (ppt); SHORT-FORM; THRESHOLD; REPEATABILITY; INDIVIDUALS; SENSITIVITY; ASSOCIATION; VALIDITY; MUSCLES; PEOPLE;
D O I
10.7759/cureus.66350
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction Non-specific chronic neck pain (NSCNP) is a musculoskeletal disorder that affects 45%-54% of the general population. There is a strong correlation between patient-reported pain and mechanical pain pressure threshold (PPT) measured with an algometer. Purpose This study aims to investigate the intra- and inter-rater reliability of the Commander algometer in Greek NSCNP patients, in an urban primary care setting. Methods Thirty-three patients (22 women and 11 men) suffering from NSCNP (>3 months), the majority (42.4%) between the ages of 50 years and 59 years and overweight, were measured bilaterally both at the neck (mastoid, trapezius head-insertion and mid-portion, C5-C6 facet, insertion of levator scapula) and at the control areas (mid-deltoid and tibialis anterior) using the Commander algometer. Measurements were taken twice over a span of six days, by two raters, in a primary care setting. Intraclass correlation coefficient (ICC) statistics were used as measures of reliability (p = 0.05). Results Intra-rater reliability was "moderate to good" for both raters. ICC values for PPT at the seven bilaterally measured sites varied between 0.67 and 0.86 for the first rater (p < 0.001) and 0.64 and 0.82 for the second rater (p < 0.003). The inter-rater reliability was "moderate to excellent" (ICC = 0.68-0.92) in the first measurement (T1) and "moderate to good" (ICC = 0.68 to 0.89) in the second measurement (T2). Conclusion This study supports the intra- and inter-rater reliability of the Commander algometer in detecting reliably the mechanical PPT, in Greek NSCNP patients, as measured according to the procedures and methodology followed throughout this study.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Intra-rater and inter-rater reliability of pressure pain threshold assessment in stroke patients
    Zhang, Yong-Hui
    Wang, Yu-Chen
    Hu, Gong-Wei
    Ding, Xiao-Qin
    Shen, Xiao-Hua
    Ng, Hui Ya
    Rong, Ji-Feng
    Wang, Xue-Qiang
    EUROPEAN JOURNAL OF PHYSICAL AND REHABILITATION MEDICINE, 2022, 58 (04) : 549 - 557
  • [2] Intra-rater and inter-rater reliability of six musculoskeletal preparticipatory screening tests
    Zumana, Nosipho
    Olivier, Benita
    Godlwana, Lonwabo
    Martin, Candice
    SOUTH AFRICAN JOURNAL OF PHYSIOTHERAPY, 2019, 75 (01)
  • [3] Intra-rater and inter-rater reliability of cranio cervical flexion test in symptomatic subjects of neck pain using pressure biofeedback
    Rajalaxmi, V.
    Kotteswari, S.
    Nisha, R. Nithya
    Nallathambi, Mohan
    BANGLADESH JOURNAL OF MEDICAL SCIENCE, 2023, 22 (03): : 617 - 622
  • [4] Inter-rater and intra-rater reliability of the Brief-BESTest in people with chronic obstructive pulmonary disease
    Leung, Regina Wai Man
    Alison, Jennifer A.
    McKeough, Zoe J.
    CLINICAL REHABILITATION, 2019, 33 (01) : 104 - 112
  • [5] Instrumental validity and intra/inter-rater reliability of a novel low-cost digital pressure algometer
    Jerez-Mayorga, Daniel
    dos Anjos, Carolina Fernanda
    Macedo, Maria de Cassia
    Fernandes, Ilha Goncalves
    Aedo-Munoz, Esteban
    Intelangelo, Leonardo
    Barbosa, Alexandre Carvalho
    PEERJ, 2020, 8
  • [6] Inter-Rater and Intra-Rater Reliability of the Bahasa Melayu Version of Rose Angina Questionnaire
    Hassan, N. B.
    Choudhury, S. R.
    Naing, L.
    Conroy, R. M.
    Rahman, A. R. A.
    ASIA-PACIFIC JOURNAL OF PUBLIC HEALTH, 2007, 19 (03) : 45 - 51
  • [7] Intra-rater and inter-rater reliability of the rapid entire body assessment (REBA) tool
    Schwartz, Adam H.
    Albin, Thomas J.
    Gerberich, Susan G.
    INTERNATIONAL JOURNAL OF INDUSTRIAL ERGONOMICS, 2019, 71 : 111 - 116
  • [8] Inter-rater and Intra-rater Reliability of the Videofluoroscopic Dysphagia Scale with the Standardized Protocol
    Min, Ingi
    Woo, Hyeonseong
    Kim, Jae Yoon
    Kim, Tae-Lim
    Lee, Yookyung
    Chang, Won Kee
    Jung, Se Hee
    Lee, Woo Hyung
    Oh, Byung-Mo
    Han, Tai Ryoon
    Seo, Han Gil
    DYSPHAGIA, 2024, 39 (01) : 43 - 51
  • [9] Inter-Rater and Intra-Rater Reliability of the Kansas University Sitting Balance Scale
    Franc, Ingrid A.
    Mauldin, Samantha
    Roberts, Magdalena
    Rosa-DiStefano, Gregoria
    OCCUPATIONAL THERAPY IN HEALTH CARE, 2023, 37 (04) : 595 - 605
  • [10] Intra-Rater and Inter-Rater Reliability of Pressure Pain Algometry of the Sural and Tibial Nerves in Asymptomatic Elite Youth Footballers
    Richards, Daniel
    Jones, Simon
    Jeffery, Josh
    Lowe, Matthew
    Godwin, Mark
    Willett, Matthew
    SPORTS, 2021, 9 (09)