Assessment of Reliability, Agreement, and Accuracy of Masseter Muscle Ultrasound Thickness Measurement Using a New Standardized Protocol

被引:1
作者
Rogulski, Mateusz [1 ]
Palac, Malgorzata [1 ,2 ]
Wolny, Tomasz [2 ]
Linek, Pawel [1 ,2 ]
机构
[1] Jerzy Kukuczka Acad Phys Educ, Musculoskeletal Diagnost & Physiotherapy Res Team, PL-40065 Katowice, Poland
[2] Jerzy Kukuczka Acad Phys Educ, Inst Physiotherapy & Hlth Sci, Musculoskeletal Elastog & Ultrasonog Lab, PL-40065 Katowice, Poland
关键词
masseter muscle; ultrasound imaging; reliability; computed tomography; ULTRASONOGRAPHY; MORPHOLOGY; SIZE; AGE;
D O I
10.3390/diagnostics14161771
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
There is no validated method of assessing masseter muscle thickness (MMT) by ultrasound imaging (US). However, this is important to ensure study and measurement quality of MMT by US in future studies, as MMT differs depending on the examined area. Thus, this study's aim was to present a new standardized method for assessing the MMT by US and to evaluate the reliability, consistency, and accuracy of its measurements. We also compared the results of MMT measurements obtained by US and computer tomography (CT). The study included nine healthy adults. The US and CT scans were collected in a supine rest position with the mandible in relaxed position. US measurements were determined according to a new standardized protocol (with precise probe location). The MMT measured by CT and US over a seven-day interval showed excellent intra-rater reliability. The mean MMT measured by CT was 12.1 mm (1.74) on the right side and 11.9 mm (1.61) on the left side. The mean MMT measured by US was 12.7 mm (2.00) on the right side and 11.5 mm (1.37) on the left side. The mean percent error in MMT measurement between CT and US was below 6%. A strong linear relationship was found between the CT and US measurements of the MMT on both body sides (p < 0.001, r >= 0.93). The proposed method of MMT measurement using US demonstrated excellent reliability, yielding results similar to those obtained from CT images. We recommend the use of this standardization protocol in further studies where precise assessment of MMT by US is expected.
引用
收藏
页数:11
相关论文
共 28 条
[1]   Ultrasound evaluation of masseter muscle changes in stabilization splint treatment of myofascial type painful temporomandibular diseases [J].
Aldemir, Korkut ;
Ustuner, Evren ;
Erdem, Erdal ;
Demiralp, A. Samimi ;
Oztuna, Derya .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY, 2013, 116 (03) :377-383
[2]  
Ariji Y, 2017, JPN DENT SCI REV, V53, P11, DOI 10.1016/j.jdsr.2016.05.001
[3]   Effect of complete edentulism on masseter muscle thickness and changes after complete denture rehabilitation: an ultrasonographic study [J].
Bhoyar, Parag Sudhakar ;
Godbole, Surekha R. ;
Thombare, Ram U. ;
Pakhan, Ashok J. .
JOURNAL OF INVESTIGATIVE AND CLINICAL DENTISTRY, 2012, 3 (01) :45-50
[4]   Methods of Masseter and Temporal Muscle Thickness and Elasticity Mea-surements by Ultrasound Imaging: A Literature Review [J].
Blicharz, Gabriela ;
Rymarczyk, Malgorzata ;
Rogulski, Mateusz ;
Linek, Pawel .
CURRENT MEDICAL IMAGING, 2021, 17 (06) :707-713
[5]   Evaluation of Masseter Muscle Hypertrophy in Oral Submucous Fibrosis Patients - An Ultrasonographic Study [J].
Chakarvarty, Ankkita ;
Panat, Sunil R. ;
Sangamesh, N. C. ;
Aggarwal, Ashish ;
Chandra, Prakash J. H. A. .
JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2014, 8 (09) :ZC45-ZC47
[6]  
CICCHETTI DV, 1981, AM J MENT DEF, V86, P127
[7]   Reliability and temporal variation of masseter muscle thickness measurements utilizing ultrasonography [J].
Emshoff, R ;
Emshoff, I ;
Rudisch, A ;
Bertram, S .
JOURNAL OF ORAL REHABILITATION, 2003, 30 (12) :1168-1172
[8]   Standardization of the ultrasound examination of the masseter muscle with size-independent calculation of records [J].
Gawriolek, Krzysztof ;
Klatkiewicz, Tomasz ;
Przystanska, Agnieszka ;
Maciejewska-Szaniec, Zofia ;
Gedrange, Tomasz ;
Czajka-Jakubowska, Agata .
ADVANCES IN CLINICAL AND EXPERIMENTAL MEDICINE, 2021, 30 (04) :441-447
[9]   Masseter Muscle Thickness Measured by Ultrasound as a Possible Link with Sarcopenia, Malnutrition and Dependence in Nursing Homes [J].
Gonzalez-Fernandez, Mikel ;
Perez-Nogueras, Javier ;
Serrano-Oliver, Antonio ;
Torres-Anoro, Elena ;
Sanz-Arque, Alejandro ;
Arbones-Mainar, Jose M. ;
Sanz-Paris, Alejandro .
DIAGNOSTICS, 2021, 11 (09)
[10]   Association between myotonometric measurement of masseter muscle stiffness and maximum bite force in healthy elders [J].
Hara, Koji ;
Namiki, Chizuru ;
Yamaguchi, Kohei ;
Kobayashi, Kenichiro ;
Saito, Takayuki ;
Nakagawa, Kazuharu ;
Ishii, Miki ;
Okumura, Takuma ;
Tohara, Haruka .
JOURNAL OF ORAL REHABILITATION, 2020, 47 (06) :750-756