Dual column chromatography combined with high-resolution mass spectrometry improves coverage of non-targeted analysis of plant root exudates

被引:1
|
作者
Bennett, Alexandra A. [1 ]
Steininger-Mairinger, Teresa [1 ]
Eroglu, Cagla Gorkem [2 ]
Gfeller, Aurelie [2 ]
Wirth, Judith [2 ]
Puschenreiter, Markus [3 ]
Hann, Stephan [1 ]
机构
[1] BOKU Univ, Inst Analyt Chem, Dept Chem, A-1190 Vienna, Austria
[2] Agroscope, Herbol Field Crops, Plant Prod Syst, Nyon, Switzerland
[3] BOKU Univ, Inst Soil Res, Dept Forest & Soil Sci, A-3430 Tulln, Austria
基金
瑞士国家科学基金会; 奥地利科学基金会;
关键词
Dual column chromatography; Data dependent acquisition; Non-targeted analysis; High-resolution mass spectrometry; Rhizosphere; LIQUID-CHROMATOGRAPHY; PHENOLIC-COMPOUNDS; STATIONARY PHASES; EXTRACTION; SUPPRESSION; RETENTION; CARBON; METABOLITES; MECHANISM;
D O I
10.1016/j.aca.2024.343126
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Background: Within the plant kingdom, there is an exceptional amount of chemical diversity that has yet to be annotated. It is for this reason that non-targeted analysis is of interest for those working in novel natural products. To increase the number and diversity of compounds observable in root exudate extracts, several workflows which differ at three key stages were compared: 1) sample extraction, 2) chromatography, and 3) data preprocessing. Results: Plants were grown in Hoagland's solution for two weeks, and exudates were initially extracted with water, followed by a 24-h regeneration period with subsequent extraction using methanol. Utilizing the second extraction showed improved results with less ion suppression and reduced retention time shifting compared to the first extraction. A single column method, utilizing a pentafluorophenyl column, paired with high-resolution mass spectrometry ionized and correctly identified 34 mock root exudate compounds, while the dual column method, incorporating a pentafluorophenyl column and a porous graphitic carbon column, retained and identified 43 compounds. In a pooled quality control sample of exudate extracts, the single column method detected 1,444 compounds. While the dual method detected fewer compounds overall (1,050), it revealed a larger number of small polar compounds. Three preprocessing methods (targeted, proprietary, and open source) successfully identified 43, 31, and 38 mock root exudate compounds to confidence level 1, respectively. Significance: Enhancing signal strength and analytical method stability involves removing the high ionic strength nutrient solution before sampling root exudate extracts. Despite signal intensity loss, a dual column method enhances compound coverage, particularly for small polar metabolites. Open-source software proves a viable alternative for non-targeted analysis, even surpassing proprietary software in peak picking.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] Optimized chemical coverage and data quality for non-targeted screening applications using liquid chromatography/high-resolution mass spectrometry
    Knolhoff, Ann M.
    Kneapler, Caitlin N.
    Croley, Timothy R.
    ANALYTICA CHIMICA ACTA, 2019, 1066 : 93 - 101
  • [2] Data processing strategies for non-targeted analysis of foods using liquid chromatography/high-resolution mass spectrometry
    Fisher, Christine M.
    Croley, Timothy R.
    Knolhoff, Ann M.
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2021, 136
  • [3] Non-targeted analysis with high-resolution mass spectrometry for investigation of riverbank filtration processes
    Kutlucinar, Kaan Georg
    Handl, Sebastian
    Allabashi, Roza
    Causon, Tim
    Troyer, Christina
    Mayr, Ernest
    Perfler, Reinhard
    Hann, Stephan
    ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2022, 29 (43) : 64568 - 64581
  • [4] Non-targeted analysis with high-resolution mass spectrometry for investigation of riverbank filtration processes
    Kaan Georg Kutlucinar
    Sebastian Handl
    Roza Allabashi
    Tim Causon
    Christina Troyer
    Ernest Mayr
    Reinhard Perfler
    Stephan Hann
    Environmental Science and Pollution Research, 2022, 29 : 64568 - 64581
  • [5] Non-targeted analysis of tea by hydrophilic interaction liquid chromatography and high resolution mass spectrometry
    Fraser, Karl
    Harrison, Scott J.
    Lane, Geoff A.
    Otter, Don E.
    Hemar, Yacine
    Quek, Siew-Young
    Rasmussen, Susanne
    FOOD CHEMISTRY, 2012, 134 (03) : 1616 - 1623
  • [6] Non-targeted screening of pesticides for food analysis using liquid chromatography high-resolution mass spectrometry-a review
    Guo, Zeqin
    Zhu, Zhiguo
    Huang, Sheng
    Wang, Jianhua
    FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT, 2020, 37 (07): : 1180 - 1201
  • [7] Parallel targeted and non-targeted quantitative analysis of steroids in human serum and peritoneal fluid by liquid chromatography high-resolution mass spectrometry
    Thomas Andrieu
    Therina du Toit
    Bruno Vogt
    Michael D. Mueller
    Michael Groessl
    Analytical and Bioanalytical Chemistry, 2022, 414 : 7461 - 7472
  • [8] Parallel targeted and non-targeted quantitative analysis of steroids in human serum and peritoneal fluid by liquid chromatography high-resolution mass spectrometry
    Andrieu, Thomas
    du Toit, Therina
    Vogt, Bruno
    Mueller, Michael D.
    Groessl, Michael
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2022, 414 (25) : 7461 - 7472
  • [9] The chromatographic role in high resolution mass spectrometry for non-targeted analysis
    Croley, Timothy R.
    White, Kevin D.
    Callahan, John H.
    Musser, Steven M.
    Journal of the American Society for Mass Spectrometry, 2012, 23 (09): : 1569 - 1578
  • [10] The Chromatographic Role in High Resolution Mass Spectrometry for Non-Targeted Analysis
    Croley, Timothy R.
    White, Kevin D.
    Callahan, John H.
    Musser, Steven M.
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2012, 23 (09) : 1569 - 1578