摘要
Acute myeloid leukemia (AML) is a common type of acute leukemia (AL), belonging to malignant tumors of the hematopoietic system with the characteristics of rapid disease development, control with extreme difficulties, easy recurrence, poor prognosis, and incidence rate increasing with age. The traditionally diagnostic standard of French American British (FAB), being based on the morphological examination with high human subjectivity, can no longer meet the demand of clinical diagnosis and treatment of AML. Requirements of objective accuracy and low-dose sample, have become the indispensable method for AML diagnosis and monitoring prognosis. Flow cytometry is a modern technology that can quickly and accurately detect the series, antigen distribution, differentiation stage of AML cells, minimal residual lesions after AML therapy, so as to provide the great significance in guiding clinical diagnosis, hierarchical treatment, and prognosis judgement. This article will systematically elaborate on the application of flow cytometry in the diagnosis and classification of AML, and the detection of minimal residual lesions, thereby providing reference significance for dynamic monitoring and prognostic observation of AML with different immune subtypes of FAB.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Multidimensional flow cytometry for detection of minimal residual disease in acute myeloid leukemia
    Venditti, A
    Maurillo, L
    Buccisano, F
    Tamburini, A
    Del Poeta, G
    Del Principe, MI
    Panetta, P
    Consalvo, MI
    Mazzone, C
    Tendas, A
    Trawinska, M
    Forte, V
    Amadori, S
    LEUKEMIA & LYMPHOMA, 2003, 44 (03) : 445 - 450
  • [2] Impact of pretransplant minimal residual disease detection by flow cytometry in acute myeloid leukemia
    Perez, E.
    Lopez-Godino, O.
    Cabrero, M.
    Labrador, J.
    Alonso, S.
    Perez, J. J.
    Lopez-Corral, L.
    Vazquez, L.
    Gonzalez, M.
    Hernadez, J. M.
    Puig, N.
    Diez-Campelo, M.
    Martin, A.
    Mateos, M. V.
    Paiva, B.
    del Canizo, M. C.
    San Miguel, J.
    Caballero, M. D.
    Vidriales, M. B.
    BONE MARROW TRANSPLANTATION, 2015, 50 : S238 - S239
  • [3] The Role of Multiparameter Flow Cytometry for Detection of Minimal Residual Disease in Acute Myeloid Leukemia
    Al-Mawali, Adhra
    Gillis, David
    Lewis, Ian
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2009, 131 (01) : 16 - 26
  • [4] Detection of minimal residual disease in acute leukemia by flow cytometry
    Campana, D
    Coustan-Smith, E
    CYTOMETRY, 1999, 38 (04): : 139 - 152
  • [5] Minimal Residual Disease Monitoring by Flow Cytometry in Pediatric Acute Myeloid Leukemia
    Rubnitz, J.
    ANNALS OF HEMATOLOGY, 2013, 92 : S55 - S55
  • [6] Minimal residual disease detection in cryopreserved ovarian tissue by multicolor flow cytometry in acute myeloid leukemia
    Zver, Tristan
    Alvergnas-Vieille, Magalie
    Garnache-Ottou, Francine
    Ferrand, Christophe
    Roux, Christophe
    Amiot, Clotilde
    HAEMATOLOGICA, 2014, 99 (12)
  • [7] Defining minimal residual disease by flow cytometry in acute myeloid leukemia: the HARMONIZE initiative
    Buecklein, V. L.
    Krause, S.
    Oelschlaegel, U.
    Koehnke, T.
    Schnorfeil, F.
    Voelkl, S.
    Rieger, M. A.
    Berg, T.
    Hoffmann, J.
    Brendel, C.
    Hiddemann, W.
    Subklewe, M.
    von Bonin, M.
    ONCOLOGY RESEARCH AND TREATMENT, 2017, 40 : 43 - 43
  • [8] DETECTION OF MINIMAL RESIDUAL DISEASE IN ACUTE-LEUKEMIA BY FLOW-CYTOMETRY
    VISSER, JWM
    MARTENS, ACM
    HAGENBEEK, A
    ANNALS OF THE NEW YORK ACADEMY OF SCIENCES, 1986, 468 : 268 - 275
  • [9] Reproducibility of measurable residual disease detection by flow cytometry in acute myeloid leukemia
    Roehnert, M. A.
    Kramer, M.
    Schadt, J.
    Ensel, P.
    Thiede, C.
    Krause, S.
    Buecklein, V
    Hoffmann, J.
    Jaramillo, S.
    Schlenk, R.
    Roellig, C.
    Bornhaeuser, M.
    McCarthy, N.
    Freeman, S.
    Oelschlaegel, U.
    von Bonin, M.
    ONCOLOGY RESEARCH AND TREATMENT, 2022, 45 (SUPPL 2) : 278 - 278
  • [10] Minimal residual disease studies by flow cytometry in acute leukemia
    Campana, D
    Coustan-Smith, E
    ACTA HAEMATOLOGICA, 2004, 112 (1-2) : 8 - 15