Improvement of Tumor Neoantigen Detection by High-Field Asymmetric Waveform Ion Mobility Mass Spectrometry

被引:1
|
作者
Meng, Wei [1 ,2 ]
Takeuchi, Yoshiko [1 ,2 ]
Ward, Jeffrey P. [1 ,2 ,3 ]
Sultan, Hussein [1 ,2 ]
Arthur, Cora D. [1 ]
Mardis, Elaine R. [4 ]
Artyomov, Maxim N. [1 ,2 ]
Lichti, Cheryl F. [1 ,2 ]
Schreiber, Robert D. [1 ,2 ]
机构
[1] Washington Univ, Sch Med, Dept Pathol & Immunol, Box 8118,660 South Euclid Ave, St Louis, MO 63110 USA
[2] Washington Univ, Sch Med, Andrew M & Jane M Bursky Ctr, Human Immunol & Immunotherapy Programs, St Louis, MO USA
[3] Washington Univ, Sch Med, Dept Med, St Louis, MO USA
[4] Nationwide Childrens Hosp, Steve & Cindy Rasmussen Inst Genom Med, Columbus, OH USA
关键词
IMMUNE-RESPONSES; CANCER; INTERLEUKIN-12; INFLAMMATION; LYMPHOCYTES; ANTITUMOR; MUTANOME; VACCINES; REVEALS; GAMMA;
D O I
10.1158/2326-6066.CIR-23-0900
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Under standard conditions, MS-based detection of rare, clinically relevant cancer neoantigens is relatively insensitive. The authors show that FAIMS can substantially improve this, allowing for detection of bona fide, biologically relevant tumor neoantigens from limited native tissue samples. Cancer neoantigens have been shown to elicit cancer-specific T-cell responses and have garnered much attention for their roles in both spontaneous and therapeutically induced antitumor responses. Mass spectrometry (MS) profiling of tumor immunopeptidomes has been used, in part, to identify MHC-bound mutant neoantigen ligands. However, under standard conditions, MS-based detection of such rare but clinically relevant neoantigens is relatively insensitive, requiring 300 million cells or more. Here, to quantitatively define the minimum detectable amounts of therapeutically relevant MHC-I and MHC-II neoantigen peptides, we analyzed different dilutions of immunopeptidomes isolated from the well-characterized T3 mouse methylcholanthrene (MCA)-induced cell line by MS. Using either data-dependent acquisition or parallel reaction monitoring (PRM), we established the minimum amount of material required to detect the major T3 neoantigens in the presence or absence of high field asymmetric waveform ion mobility spectrometry (FAIMS). This analysis yielded a 14-fold enhancement of sensitivity in detecting the major T3 MHC-I neoantigen (mLama4) with FAIMS-PRM compared with PRM without FAIMS, allowing ex vivo detection of this neoantigen from an individual 100 mg T3 tumor. These findings were then extended to two other independent MCA-sarcoma lines (1956 and F244). This study demonstrates that FAIMS substantially increases the sensitivity of MS-based characterization of validated neoantigens from tumors.
引用
收藏
页码:988 / 1006
页数:19
相关论文
共 50 条
  • [31] Analysis of paralytic shellfish toxins using high-field asymmetric waveform ion mobility spectrometry with liquid chromatography-mass spectrometry
    Daniel G. Beach
    Jeremy E. Melanson
    Randy W. Purves
    Analytical and Bioanalytical Chemistry, 2015, 407 : 2473 - 2484
  • [32] ANYL 376-Separation and characterization of explosive compounds using high-field asymmetric waveform ion mobility spectrometry/mass spectrometry
    Wu, Ching-Hong Alex
    Yost, Richard A.
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2008, 236
  • [33] Removal of metabolite interference during liquid chromatography/tandem mass spectrometry using high-field asymmetric waveform ion mobility spectrometry
    Kapron, JT
    Jemal, M
    Duncan, G
    Kolakowski, B
    Purves, R
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2005, 19 (14) : 1979 - 1983
  • [34] Analysis of paralytic shellfish toxins using high-field asymmetric waveform ion mobility spectrometry with liquid chromatography-mass spectrometry
    Beach, Daniel G.
    Melanson, Jeremy E.
    Purves, Randy W.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2015, 407 (09) : 2473 - 2484
  • [35] High-Field Asymmetric Waveform Ion Mobility Spectrometry: Practical Alternative for Cardiac Proteome Sample Processing
    Ai, Lizhuo
    Binek, Aleksandra
    Kreimer, Simion
    Ayres, Matthew
    Stotland, Aleksandr
    Van Eyk, Jennifer E.
    JOURNAL OF PROTEOME RESEARCH, 2023, 22 (06) : 2124 - 2130
  • [36] Integration of paper spray ionization high-field asymmetric waveform ion mobility spectrometry for forensic applications
    Tsai, Chia-Wei
    Tipple, Christopher A.
    Yost, Richard A.
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2018, 32 (07) : 552 - 560
  • [37] Peak deconvolution in high-field asymmetric waveform ion mobility spectrometry (FAIMS) to characterize macromolecular conformations
    Robinson, Errol W.
    Sellon, Rachel E.
    Williams, Evan R.
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2007, 259 (1-3) : 87 - 95
  • [38] Separation of β2-microglobulin conformers by high-field asymmetric waveform ion mobility spectrometry (FAIMS) coupled to electrospray ionisation mass spectrometry
    Borysik, AJH
    Read, P
    Little, DR
    Bateman, RH
    Radford, SE
    Ashcroft, AE
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2004, 18 (19) : 2229 - 2234
  • [39] Orbitrap Mass Spectrometry and High-Field Asymmetric Waveform Ion Mobility Spectrometry (FAIMS) Enable the in-Depth Analysis of Human Serum Proteoforms
    Kline, Jake T.
    Belford, Michael W.
    Boeser, Cornelia L.
    Huguet, Romain
    Fellers, Ryan T.
    Greer, Joseph B.
    Greer, Sylvester M.
    Horn, David M.
    Durbin, Kenneth R.
    Dunyach, Jean-Jacques
    Ahsan, Nagib
    Fornelli, Luca
    JOURNAL OF PROTEOME RESEARCH, 2023, 22 (11) : 3418 - 3426
  • [40] Simultaneous Detection of o- , m- , p-Xylene by High-field Asymmetric Waveform Ion Mobility Spectrometry
    Wang Han
    Liu You-Jiang
    Li Shan
    Xu Qing
    Hu Jun
    Ma He
    Chen Chi-Lai
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2019, 47 (06) : 933 - 940