Improvement of Tumor Neoantigen Detection by High-Field Asymmetric Waveform Ion Mobility Mass Spectrometry

被引:1
|
作者
Meng, Wei [1 ,2 ]
Takeuchi, Yoshiko [1 ,2 ]
Ward, Jeffrey P. [1 ,2 ,3 ]
Sultan, Hussein [1 ,2 ]
Arthur, Cora D. [1 ]
Mardis, Elaine R. [4 ]
Artyomov, Maxim N. [1 ,2 ]
Lichti, Cheryl F. [1 ,2 ]
Schreiber, Robert D. [1 ,2 ]
机构
[1] Washington Univ, Sch Med, Dept Pathol & Immunol, Box 8118,660 South Euclid Ave, St Louis, MO 63110 USA
[2] Washington Univ, Sch Med, Andrew M & Jane M Bursky Ctr, Human Immunol & Immunotherapy Programs, St Louis, MO USA
[3] Washington Univ, Sch Med, Dept Med, St Louis, MO USA
[4] Nationwide Childrens Hosp, Steve & Cindy Rasmussen Inst Genom Med, Columbus, OH USA
关键词
IMMUNE-RESPONSES; CANCER; INTERLEUKIN-12; INFLAMMATION; LYMPHOCYTES; ANTITUMOR; MUTANOME; VACCINES; REVEALS; GAMMA;
D O I
10.1158/2326-6066.CIR-23-0900
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Under standard conditions, MS-based detection of rare, clinically relevant cancer neoantigens is relatively insensitive. The authors show that FAIMS can substantially improve this, allowing for detection of bona fide, biologically relevant tumor neoantigens from limited native tissue samples. Cancer neoantigens have been shown to elicit cancer-specific T-cell responses and have garnered much attention for their roles in both spontaneous and therapeutically induced antitumor responses. Mass spectrometry (MS) profiling of tumor immunopeptidomes has been used, in part, to identify MHC-bound mutant neoantigen ligands. However, under standard conditions, MS-based detection of such rare but clinically relevant neoantigens is relatively insensitive, requiring 300 million cells or more. Here, to quantitatively define the minimum detectable amounts of therapeutically relevant MHC-I and MHC-II neoantigen peptides, we analyzed different dilutions of immunopeptidomes isolated from the well-characterized T3 mouse methylcholanthrene (MCA)-induced cell line by MS. Using either data-dependent acquisition or parallel reaction monitoring (PRM), we established the minimum amount of material required to detect the major T3 neoantigens in the presence or absence of high field asymmetric waveform ion mobility spectrometry (FAIMS). This analysis yielded a 14-fold enhancement of sensitivity in detecting the major T3 MHC-I neoantigen (mLama4) with FAIMS-PRM compared with PRM without FAIMS, allowing ex vivo detection of this neoantigen from an individual 100 mg T3 tumor. These findings were then extended to two other independent MCA-sarcoma lines (1956 and F244). This study demonstrates that FAIMS substantially increases the sensitivity of MS-based characterization of validated neoantigens from tumors.
引用
收藏
页码:988 / 1006
页数:19
相关论文
共 50 条
  • [21] Evaluation of carrier gases for use in high-field asymmetric waveform ion mobility spectrometry
    Barnett, DA
    Ells, B
    Guevremont, R
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2000, 11 (12) : 1125 - 1133
  • [22] Quantitation of morphine and codeine in human urine using high-field asymmetric waveform ion mobility spectrometry (FAIMS) with mass spectrometric detection
    McCooeye, MA
    Ells, B
    Barnett, DA
    Purves, RW
    Guevremont, R
    JOURNAL OF ANALYTICAL TOXICOLOGY, 2001, 25 (02) : 81 - 87
  • [23] High-Field Asymmetric Waveform Ion Mobility Spectrometry and Native Mass Spectrometry: Analysis of Intact Protein Assemblies and Protein Complexes
    Hale, Oliver J.
    Illes-Toth, Eva
    Mize, Todd H.
    Cooper, Helen J.
    ANALYTICAL CHEMISTRY, 2020, 92 (10) : 6811 - 6816
  • [24] Simultaneous analysis of prostanoids using liquid chromatography/high-field asymmetric waveform ion mobility spectrometry/tandem mass spectrometry
    Kapron, James
    Wu, Jin
    Mauriala, Timo
    Clark, Patsy
    Purves, Randy W.
    Bateman, Kevin P.
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2006, 20 (10) : 1504 - 1510
  • [25] Design, Fabrication and Mass-spectrometric Studies of a Micro Ion Source for High-Field Asymmetric Waveform Ion Mobility Spectrometry
    Li, Hua
    Yun, Hongmei
    Du, Xiaoxia
    Guo, Chaoqun
    Zeng, Ruosheng
    Jiang, Yongrong
    Chen, Zhencheng
    MICROMACHINES, 2019, 10 (05)
  • [26] Improvement in peptide detection for proteomics analyses using nanoLC-MS and high-field asymmetry waveform ion mobility mass spectrometry
    Venne, K
    Bonneil, E
    Eng, K
    Thibault, P
    ANALYTICAL CHEMISTRY, 2005, 77 (07) : 2176 - 2186
  • [27] Characterization and Optimization of Multiplexed Quantitative Analyses Using High-Field Asymmetric-Waveform Ion Mobility Mass Spectrometry
    Schweppe, Devin K.
    Prasad, Satendra
    Belford, Michael W.
    Navarrete-Perea, Jose
    Bailey, Derek J.
    Huguet, Romain
    Jedrychowski, Mark P.
    Rad, Ramin
    McAlister, Graeme
    Abbatiello, Susan E.
    Woulters, Eloy R.
    Zabrouskov, Vlad
    Dunyach, Jean-Jacques
    Paulo, Joao A.
    Gygi, Steven P.
    ANALYTICAL CHEMISTRY, 2019, 91 (06) : 4010 - 4016
  • [28] High-Field Asymmetric Waveform Ion Mobility Spectrometry Interface Enhances Parallel Reaction Monitoring on an Orbitrap Mass Spectrometer
    Deng, Weixian
    Sha, Jihui
    Xue, Fanglei
    Jami-Alahmadi, Yasaman
    Plath, Kathrin
    Wohlschlegel, James
    ANALYTICAL CHEMISTRY, 2022, 94 (46) : 15939 - 15947
  • [29] Effect of Carrier Gas Flow Rate on High-Field Asymmetric Waveform Ion Mobility Spectrometry
    Lin Bing-Tao
    Chen Chi-Lai
    Kong De-Yi
    Li Zhuang
    Wang Huan-Qin
    Cheng Yu-Peng
    Wang Dian-Ling
    Mei Tao
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2010, 38 (07) : 1027 - 1030
  • [30] Global Phosphoproteome Analysis Using High-Field Asymmetric Waveform Ion Mobility Spectrometry on a Hybrid Orbitrap Mass Spectrometer
    Muehlbauer, Laura K.
    Hebert, Alexander S.
    Westphall, Michael S.
    Shishkova, Evgenia
    Coon, Joshua J.
    ANALYTICAL CHEMISTRY, 2020, 92 (24) : 15959 - 15967