共 50 条
Improvement of Tumor Neoantigen Detection by High-Field Asymmetric Waveform Ion Mobility Mass Spectrometry
被引:1
|作者:
Meng, Wei
[1
,2
]
Takeuchi, Yoshiko
[1
,2
]
Ward, Jeffrey P.
[1
,2
,3
]
Sultan, Hussein
[1
,2
]
Arthur, Cora D.
[1
]
Mardis, Elaine R.
[4
]
Artyomov, Maxim N.
[1
,2
]
Lichti, Cheryl F.
[1
,2
]
Schreiber, Robert D.
[1
,2
]
机构:
[1] Washington Univ, Sch Med, Dept Pathol & Immunol, Box 8118,660 South Euclid Ave, St Louis, MO 63110 USA
[2] Washington Univ, Sch Med, Andrew M & Jane M Bursky Ctr, Human Immunol & Immunotherapy Programs, St Louis, MO USA
[3] Washington Univ, Sch Med, Dept Med, St Louis, MO USA
[4] Nationwide Childrens Hosp, Steve & Cindy Rasmussen Inst Genom Med, Columbus, OH USA
关键词:
IMMUNE-RESPONSES;
CANCER;
INTERLEUKIN-12;
INFLAMMATION;
LYMPHOCYTES;
ANTITUMOR;
MUTANOME;
VACCINES;
REVEALS;
GAMMA;
D O I:
10.1158/2326-6066.CIR-23-0900
中图分类号:
R73 [肿瘤学];
学科分类号:
100214 ;
摘要:
Under standard conditions, MS-based detection of rare, clinically relevant cancer neoantigens is relatively insensitive. The authors show that FAIMS can substantially improve this, allowing for detection of bona fide, biologically relevant tumor neoantigens from limited native tissue samples. Cancer neoantigens have been shown to elicit cancer-specific T-cell responses and have garnered much attention for their roles in both spontaneous and therapeutically induced antitumor responses. Mass spectrometry (MS) profiling of tumor immunopeptidomes has been used, in part, to identify MHC-bound mutant neoantigen ligands. However, under standard conditions, MS-based detection of such rare but clinically relevant neoantigens is relatively insensitive, requiring 300 million cells or more. Here, to quantitatively define the minimum detectable amounts of therapeutically relevant MHC-I and MHC-II neoantigen peptides, we analyzed different dilutions of immunopeptidomes isolated from the well-characterized T3 mouse methylcholanthrene (MCA)-induced cell line by MS. Using either data-dependent acquisition or parallel reaction monitoring (PRM), we established the minimum amount of material required to detect the major T3 neoantigens in the presence or absence of high field asymmetric waveform ion mobility spectrometry (FAIMS). This analysis yielded a 14-fold enhancement of sensitivity in detecting the major T3 MHC-I neoantigen (mLama4) with FAIMS-PRM compared with PRM without FAIMS, allowing ex vivo detection of this neoantigen from an individual 100 mg T3 tumor. These findings were then extended to two other independent MCA-sarcoma lines (1956 and F244). This study demonstrates that FAIMS substantially increases the sensitivity of MS-based characterization of validated neoantigens from tumors.