Improvement of Tumor Neoantigen Detection by High-Field Asymmetric Waveform Ion Mobility Mass Spectrometry

被引:1
|
作者
Meng, Wei [1 ,2 ]
Takeuchi, Yoshiko [1 ,2 ]
Ward, Jeffrey P. [1 ,2 ,3 ]
Sultan, Hussein [1 ,2 ]
Arthur, Cora D. [1 ]
Mardis, Elaine R. [4 ]
Artyomov, Maxim N. [1 ,2 ]
Lichti, Cheryl F. [1 ,2 ]
Schreiber, Robert D. [1 ,2 ]
机构
[1] Washington Univ, Sch Med, Dept Pathol & Immunol, Box 8118,660 South Euclid Ave, St Louis, MO 63110 USA
[2] Washington Univ, Sch Med, Andrew M & Jane M Bursky Ctr, Human Immunol & Immunotherapy Programs, St Louis, MO USA
[3] Washington Univ, Sch Med, Dept Med, St Louis, MO USA
[4] Nationwide Childrens Hosp, Steve & Cindy Rasmussen Inst Genom Med, Columbus, OH USA
关键词
IMMUNE-RESPONSES; CANCER; INTERLEUKIN-12; INFLAMMATION; LYMPHOCYTES; ANTITUMOR; MUTANOME; VACCINES; REVEALS; GAMMA;
D O I
10.1158/2326-6066.CIR-23-0900
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Under standard conditions, MS-based detection of rare, clinically relevant cancer neoantigens is relatively insensitive. The authors show that FAIMS can substantially improve this, allowing for detection of bona fide, biologically relevant tumor neoantigens from limited native tissue samples. Cancer neoantigens have been shown to elicit cancer-specific T-cell responses and have garnered much attention for their roles in both spontaneous and therapeutically induced antitumor responses. Mass spectrometry (MS) profiling of tumor immunopeptidomes has been used, in part, to identify MHC-bound mutant neoantigen ligands. However, under standard conditions, MS-based detection of such rare but clinically relevant neoantigens is relatively insensitive, requiring 300 million cells or more. Here, to quantitatively define the minimum detectable amounts of therapeutically relevant MHC-I and MHC-II neoantigen peptides, we analyzed different dilutions of immunopeptidomes isolated from the well-characterized T3 mouse methylcholanthrene (MCA)-induced cell line by MS. Using either data-dependent acquisition or parallel reaction monitoring (PRM), we established the minimum amount of material required to detect the major T3 neoantigens in the presence or absence of high field asymmetric waveform ion mobility spectrometry (FAIMS). This analysis yielded a 14-fold enhancement of sensitivity in detecting the major T3 MHC-I neoantigen (mLama4) with FAIMS-PRM compared with PRM without FAIMS, allowing ex vivo detection of this neoantigen from an individual 100 mg T3 tumor. These findings were then extended to two other independent MCA-sarcoma lines (1956 and F244). This study demonstrates that FAIMS substantially increases the sensitivity of MS-based characterization of validated neoantigens from tumors.
引用
收藏
页码:988 / 1006
页数:19
相关论文
共 50 条
  • [1] High-field asymmetric waveform ion mobility spectrometry: A new tool for mass spectrometry
    Guevremont, R
    JOURNAL OF CHROMATOGRAPHY A, 2004, 1058 (1-2) : 3 - 19
  • [2] Detection of microcystins using electrospray ionization high-field asymmetric waveform ion mobility mass spectrometry/mass spectrometry
    Ells, B
    Froese, K
    Hrudey, SE
    Purves, RW
    Guevremont, R
    Barnett, DA
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2000, 14 (16) : 1538 - 1542
  • [3] An intelligent detection method for high-field asymmetric waveform ion mobility spectrometry
    Li, Yue
    Yu, Jianwen
    Ruan, Zhiming
    Chen, Chilai
    Chen, Ran
    Wang, Han
    Liu, Youjiang
    Wang, Xiaozhi
    Li, Shan
    EUROPEAN JOURNAL OF MASS SPECTROMETRY, 2018, 24 (02) : 191 - 195
  • [4] High-field asymmetric waveform ion mobility spectrometry (FAIMS)
    Guevremont, R
    CANADIAN JOURNAL OF ANALYTICAL SCIENCES AND SPECTROSCOPY, 2004, 49 (03): : 105 - 113
  • [5] High-field asymmetric waveform ion mobility spectrometry for mass spectrometry-based proteomics
    Swearingen, Kristian E.
    Moritz, Robert L.
    EXPERT REVIEW OF PROTEOMICS, 2012, 9 (05) : 505 - 517
  • [6] Electrospray ionization high-field asymmetric waveform ion mobility spectrometry-mass spectrometry
    Purves, RW
    Guevremont, R
    ANALYTICAL CHEMISTRY, 1999, 71 (13) : 2346 - 2357
  • [7] Compensation voltage shifting in high-field asymmetric waveform ion mobility spectrometry-mass spectrometry
    Kolakowski, Beata M.
    McCooeye, Margaret A.
    Mester, Zoltan
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2006, 20 (22) : 3319 - 3329
  • [8] Evaluation of high-field asymmetric waveform ion mobility spectrometry mass spectrometry for the analysis of the mycotoxin zearalenone
    McCooeye, Margaret
    Kolakowski, Beata
    Boison, Joe
    Mester, Zoltan
    ANALYTICA CHIMICA ACTA, 2008, 627 (01) : 112 - 116
  • [9] High pressure effects in high-field asymmetric waveform ion mobility spectrometry
    Wang, Yonghuan
    Wang, Xiaozhi
    Li, Lingfen
    Chen, Chilai
    Xu, Tianbai
    Wang, Tao
    Luo, Jikui
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2016, 30 (16) : 1914 - 1922
  • [10] Application of High-Field Asymmetric Waveform Ion Mobility Separation to LESA Mass Spectrometry of Bacteria
    Kocurek, Klaudia I.
    May, Robin C.
    Cooper, Helen J.
    ANALYTICAL CHEMISTRY, 2019, 91 (07) : 4755 - 4761