Optimal design and three-level stochastic energy management for an interconnected microgrid with hydrogen production and storage for fuel cell electric vehicle refueling stations

被引:11
|
作者
Nagem, Nadia A. [1 ]
Ebeed, Mohamed [2 ,3 ]
Alqahtani, Dokhyl [4 ]
Jurado, Francisco [3 ]
Khan, Noor Habib [5 ]
Hafez, Wessam A. [6 ]
机构
[1] Menoufia Univ, Fac Engn, Elect Engn Dept, Menoufia, Egypt
[2] Sohag Univ, Fac Engn, Dept Elect Engn, Sohag 82524, Egypt
[3] Univ Jaen, Dept Elect Engn, EPS Linares, Jaen 23700, Spain
[4] Prince Sattam bin Abdulaziz Univ, Elect Engn Dept, Al Kharj, Saudi Arabia
[5] North China Elect Power Univ, Dept New Energy, Beijing 102206, Peoples R China
[6] Sohag Univ, Fac Technol & Educ, Elect Dept, Sohag, Egypt
关键词
Energy management; Microgrid; Uncertainty; Renewable energy resources; Fuel cell electric vehicles; Demand side response; HYBRID AC/DC MICROGRIDS; OPTIMAL OPERATION; SYSTEM; POWER; PV; OPTIMIZATION; UNCERTAINTY; ALGORITHM; UNITS; WIND;
D O I
10.1016/j.ijhydene.2024.08.415
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
A new trend in the transportation sector globally can be observed in a shift away from gasoline-powered vehicles to Hydrogen-based fuel-cell electric vehicles (FCEVs), aimed at reducing harmful emissions. However, there are challenges in producing hydrogen for vehicle stations related to microgrid design and energy management under uncertain conditions. This research sought to identify the optimum design of an electric microgrid to provide the required energy for electric loads, together with a hydrogen refueling station. The microgrid under study consists of various renewable energy resources (RERs), such as photovoltaic (PV) devices, wind power systems, and hydrogen storage systems. The energy management strategy (EMS) aims to reduce the total costs (investment, operation, replacement, procurement energy costs) considering four uncertain parameters associated with PV panels, FCEVs, wind turbines, and power demand. A three-level EMS is proposed based on testing various solutions: without RERs or a hydrogen energy storage system (Level 1); with RERs and a hydrogen energy storage system (Level 2), with RERs and hydrogen energy storage that includes demand side response (DSR) (Level 3). The results indicate annual cost savings of 1.946 E+06 $ for Level 2 and 2.001 E+06 $ for Level 3, compared to Level 1.
引用
收藏
页码:574 / 587
页数:14
相关论文
共 34 条
  • [11] Optimal Energy Management in a Standalone Microgrid, with Photovoltaic Generation, Short-Term Storage, and Hydrogen Production
    Cecilia, Andreu
    Carroquino, Javier
    Roda, Vicente
    Costa-Castello, Ramon
    Barreras, Felix
    ENERGIES, 2020, 13 (06)
  • [12] Design and analysis of fuel cell and photovoltaic based 110V DC microgrid using hydrogen energy storage
    Alam, Mohd
    Kumar, Kuldeep
    Dutta, Viresh
    ENERGY STORAGE, 2019, 1 (03)
  • [13] Incorporating the best sizing and a new energy management approach into the fuel cell hybrid electric vehicle design
    Abdeldjalil, Djouahi
    Negrou, Bekhir
    Youssef, Touggui
    Samy, Mohamed Mahmoud
    ENERGY & ENVIRONMENT, 2025, 36 (02) : 616 - 637
  • [14] A Novel Controller Design for Small-Scale Islanded Microgrid Integrated with Electric Vehicle-Based Energy Storage Management
    Omar, Nihal
    Tiwari, Anil Kumar
    Seethalekshmi, K.
    Shrivastava, Nitin Anand
    INTERNATIONAL TRANSACTIONS ON ELECTRICAL ENERGY SYSTEMS, 2022, 2022
  • [15] Model construction and energy management system of lithium battery, PV generator, hydrogen production unit and fuel cell in islanded AC microgrid
    Zhang, Yong
    Wei, Wei
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2020, 45 (33) : 16381 - 16397
  • [16] Energy Management System for Hybrid PV/Wind/Battery/Fuel Cell in Microgrid-Based Hydrogen and Economical Hybrid Battery/Super Capacitor Energy Storage
    Sahri, Younes
    Belkhier, Youcef
    Tamalouzt, Salah
    Ullah, Nasim
    Shaw, Rabindra Nath
    Chowdhury, Md Shahariar
    Techato, Kuaanan
    ENERGIES, 2021, 14 (18)
  • [17] Ant Colony Optimization Applied to Optimal Energy Management of Fuel Cell Hybrid Electric Vehicle
    Pourhashemi, Afshin Pedram
    Ansarey M, S. M. Mehdi
    IV INTERNATIONAL CONGRESS ON ULTRA MODERN TELECOMMUNICATIONS AND CONTROL SYSTEMS 2012 (ICUMT), 2012, : 497 - +
  • [18] Energy Management of Fuel Cell/Battery and Ultra-capacitor Hybrid Energy Storage System for Electric Vehicle
    Amjadi, Zahra
    2020 IEEE POWER & ENERGY SOCIETY INNOVATIVE SMART GRID TECHNOLOGIES CONFERENCE (ISGT), 2020,
  • [19] Real-time implementation of improved power frequency approach based energy management of fuel cell electric vehicle considering storage limitations
    Badji, Abderrezak
    Abdeslam, Djaffar Ould
    Chabane, Djafar
    Benamrouche, Nacereddine
    ENERGY, 2022, 249
  • [20] A three-level model for integration of smart homes, electric vehicle charging stations and hydrogen fuelling stations in reconfigurable microgrids considering vehicle-to-infrastructure (V2I) technology
    Jordehi, Ahmad Rezaee
    Mansouri, Seyed Amir
    Tostado-Veliz, Marcos
    Hakimi, Seyed Mehdi
    Safaraliev, Murodbek
    Nasir, Mohammad
    ENERGY, 2025, 314