Prediction of punching shear strength in internal slab-column connections without shear reinforcement in reinforced concrete structures through multiple regression models

被引:1
|
作者
Lanini, Tamiris Luiza Soares [1 ]
Reis, Elvys Dias [2 ]
de Almeida Filho, Fernando Menezes [1 ]
Christoforo, Andre Luis [1 ]
机构
[1] Univ Fed Sao Carlos, Dept Civil Engn, Sao Carlos, Brazil
[2] Univ Paris Saclay, CentraleSuplec, ENS Paris Saclay, Gif Sur Yvette, France
关键词
Reinforced concrete; Flat slabs; Punching; Statistical analysis; Regression models; FLAT SLABS; TESTS; BEHAVIOR; FAILURE; PERFORMANCE; ELIMINATION; RESISTANCE; CAPACITY;
D O I
10.1007/s40430-024-05219-9
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
The structural systems' critical point of flat slabs happens on the connection slab-column through the shearing stressing concentrations, which may lead to the punching phenomenon. According to the literature, multiple factors influence punching, and much theoretical and experimental research has been developed to comprehend its behavior and then estimate the connection slab-column punching resistance. However, there is yet to be a sizing model entirely accepted by the technical-scientific community to estimate and explain such a phenomenon and its influence parameters. In this context, this study aims to propose, by statistical analysis applied to experimental studies, an ultimate punching shear strength (Pu) predictor equation of the internal slab-column connection, with no shear reinforcement and symmetrical loading, on reinforced concrete edifications. Therefore, the punching strength predictor models presented by the literature and the primary standards have been evaluated through a vast database containing the manly punching influencers' parameters. The proposed model is based on only five real model variables-slab geometry (Geo), column dimension (L), the effective height of the slab (d), compressive strength of concrete (fc), and bending reinforcement rate (rho)-and estimated the Pu on internal slab-column connection with a 3% error order and Radj2\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$R_{{{\text{adj}}}}<^>{2}$$\end{document} equal to 97.28%.
引用
收藏
页数:30
相关论文
共 50 条
  • [41] Two-way shear strength of reinforced concrete transfer slab-column connections
    Kang, Su-Min
    Na, Su-Jeong
    Hwang, Hyeon-Jong
    ENGINEERING STRUCTURES, 2021, 231
  • [42] Prediction of punching shear strength of slab-column connections: A comprehensive evaluation of machine learning and deep learning based approaches
    Derogar, Shahram
    Ince, Ceren
    Yatbaz, Hakan Yekta
    Ever, Enver
    MECHANICS OF ADVANCED MATERIALS AND STRUCTURES, 2024, 31 (06) : 1272 - 1290
  • [43] Assessment of punching shear strength of FRP-RC slab-column connections using machine learning algorithms
    Truong, Gia Toai
    Hwang, Hyeon-Jong
    Kim, Chang-Soo
    ENGINEERING STRUCTURES, 2022, 255
  • [44] Punching Shear of FRP-RC Slab-Column Connections: A Comprehensive Database
    Almomani, Yazan
    Alawadi, Roaa
    Tarawneh, Ahmad
    Alghossoon, Abdullah
    Aldiabat, Ahmad
    JOURNAL OF COMPOSITES SCIENCE, 2024, 8 (04):
  • [45] Modification of KDS 14 Design Model for Punching Shear Strength of Slab-Column Connections Reinforced with Various Types of FRP Rebars
    Dinh, Ngoc Hieu
    Kim, Si-Hyun
    Choi, Kyoung-Kyu
    INTERNATIONAL JOURNAL OF CONCRETE STRUCTURES AND MATERIALS, 2025, 19 (01)
  • [46] Punching Shear Strength of GFRP-RC Interior Slab-Column Connections Subjected to Moment Transfer
    Gouda, Ahmed
    El-Salakawy, Ehab
    JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2016, 20 (01)
  • [47] Punching shear strength of interior slab-column connections strengthened with carbon fiber reinforced polymer sheets
    Esfahani, M. R.
    Kianoush, M. R.
    Moradi, A. R.
    ENGINEERING STRUCTURES, 2009, 31 (07) : 1535 - 1542
  • [48] Numerical and analytical investigation on the moment and deformation capacity of interior slab-column connections without shear reinforcement
    Tang, Ming
    Yi, Wei-Jian
    Chen, Hui
    Wu, Yue-Fan
    ADVANCES IN STRUCTURAL ENGINEERING, 2021, 24 (16) : 3707 - 3723
  • [49] Strain-based strength model for direct punching shear of interior slab-column connections
    Park, Hong-Gun
    Choi, Kyoung-Kyu
    Chung, Lan
    ENGINEERING STRUCTURES, 2011, 33 (03) : 1062 - 1073
  • [50] Punching of reinforced concrete slab without shear reinforcement: Standard models and new proposal
    Luisa Pani
    Flavio Stochino