Experimental study on shear transfer across interfaces with post-installed shear reinforcement

被引:0
|
作者
Nie, Xin [1 ]
Huang, Da [1 ]
Liu, Tai [1 ]
Fan, Jiansheng [1 ]
机构
[1] Tsinghua Univ, Dept Civil Engn, Key Lab Civil Engn Safety & Durabil, China Educ Minist, Beijing 100084, Peoples R China
来源
JOURNAL OF BUILDING ENGINEERING | 2024年 / 97卷
基金
中国国家自然科学基金;
关键词
Precast flooring system; Fit-up issue; Post-installed rebar; Concrete-to-concrete interface; Shear transfer mechanism; CONSTRUCTION; BEHAVIOR;
D O I
10.1016/j.jobe.2024.110812
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
To address the fit-up issues arising from reinforcement congestion and limited seating area over precast beams, an improved joint detail characterized by post-installed interface shear reinforcement has been developed. The incorporation of post-installed narrower looped bars as an alternative to conventional protruding stirrups significantly expedites the erection of precast flooring systems. Moreover, direct shear tests are performed on 30 Z-shaped specimens to investigate the influence of joint details, surface roughness, looped bar ratio, and embedment length of post-installed bars on the interface shear behavior. Experimental results indicate that employing post-installed narrower looped bars not only ensures adequate seating length for precast flooring systems, but also prevents the splitting failure of concrete cover which can induce the degradation of dowel action. Sufficient anchorage is the prerequisite for post-installed looped bars to impose clamping stress on concrete interface, and a shallow embedment length may trigger the occurrence of pull-out failure. Surface roughness is another factor determining the interface shear resistance and stiffness. Untreated surfaces, in contrast to intentionally roughened surfaces, are susceptible to the cohesion fracture and may hinder the development of shear-friction action. Furthermore, a linear correlation exists between looped bar ratio and the shear resistance of concrete interface. Based on the experimental results, design recommendations, including the minimum required anchorage length for post-installed looped bars, are proposed for the novel joint detail.
引用
收藏
页数:22
相关论文
共 50 条
  • [21] Experimental study on the tensile response of post-installed adhesive anchor connections in reinforced and plain concrete beams
    Sartipi, Sahand
    Emrani, Seyed Mohammad Reza
    Epackachi, Siamak
    Erfani, Saeed
    STRUCTURAL CONCRETE, 2022, 23 (04) : 2542 - 2561
  • [22] Structural behaviour of post-installed reinforcement for 3D concrete printed shells - A case study on water tanks
    Gebhard, Lukas
    Mata-Falcon, Jaime
    Iqbal, Arsalan
    Kaufmann, Walter
    CONSTRUCTION AND BUILDING MATERIALS, 2023, 366
  • [23] Discrete mesoscale analysis of adhesive anchors under tensile load taking into account post-installed reinforcement
    Siamakani, Seyed Yaser Mousavi
    Jiradilok, Punyawut
    Nagai, Kohei
    Sahamitmongkol, Raktipong
    CONSTRUCTION AND BUILDING MATERIALS, 2020, 262
  • [24] Study on Seismic Damage Model of Post-installed Connection Between Steel and Concrete
    Xie, Qun
    Xue, Song
    Xu, Lei
    INTERNATIONAL JOURNAL OF CIVIL ENGINEERING, 2018, 16 (9A) : 1201 - 1211
  • [25] Prevention of concrete breakout failure of expansion anchor in tension by post-installed reinforcement: Discrete analysis and experiment
    Siamakani, Seyed Yaser Mousavi
    Nagai, Kohei
    Jiradilok, Punyawut
    Sahamitmongkol, Raktipong
    CASE STUDIES IN CONSTRUCTION MATERIALS, 2022, 17
  • [26] Exploration of shear transfer strength of ultra-high performance concrete with shear reinforcement
    Dong, Li
    Hao, Meijing
    Chang, Wei
    STRUCTURES, 2024, 69
  • [27] Punching shear strength of reinforced concrete transfer slab-column connections with shear reinforcement
    Kang, Su-Min
    Na, Su-Jeong
    Hwang, Hyeon-Jong
    ENGINEERING STRUCTURES, 2021, 243
  • [28] Interfacial failure and arching of the CRTS II slab track reinforced by post-installed reinforcement bars due to thermal effects
    Li, Yang
    Chen, Jinjie
    Wang, Jianxi
    Shi, Xianfeng
    Wang, Rui
    ENGINEERING FAILURE ANALYSIS, 2021, 125
  • [29] Cast-in and post-installed rebar anchorage systems in RC column foundation joints: Experimental investigations
    Mahadik, Vinay
    Sharma, Akanshu
    Hofmann, Jan
    ENGINEERING STRUCTURES, 2021, 238
  • [30] Experimental Investigations on the Influence of the Slab Width and the Moment-Shear-Ratio on the Shear Capacity of RC Slabs without Shear Reinforcement
    Adam, V.
    Herbrand, M.
    Classen, M.
    BAUINGENIEUR, 2018, 93 : 37 - 45