Intraocular Pressure Measurements in Standing, Sitting, Prone, and Supine Positions

被引:1
作者
De Bernardo, Maddalena [1 ]
Cione, Ferdinando [1 ]
De Pascale, Ilaria [1 ]
Pagliarulo, Sergio [1 ]
Rosa, Nicola [1 ]
机构
[1] Univ Salerno, Scuola Med Salernitana, Dept Med Surg & Dent, Eye Unit, I-84081 Salerno, Italy
来源
JOURNAL OF PERSONALIZED MEDICINE | 2024年 / 14卷 / 08期
关键词
intraocular pressure; hand-held tonometer; standing position; supine position; sitting position; normal-tension glaucoma; BODY POSITION; GLAUCOMA PROGRESSION; RISK-FACTOR; FLUCTUATION; PNEUMATONOMETER; TONOMETER; HEAD;
D O I
10.3390/jpm14080826
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
In this study, intraocular pressure (IOP) was measured in sitting, supine, prone, and standing (ST) positions and again five minutes after standing (ST-5) utilizing a Tono-Pen AVIA in 124 eyes of 62 healthy subjects with ages ranging from 21 to 59 years (mean 30 +/- 10 years). In each subject, the average IOP of both eyes was used for the statistical evaluation. The mean IOP difference between the ST and sitting positions was -0.13 +/- 1.63 mmHg (p = 0.548); between ST-5 and sitting, it was 0.53 +/- 1.24 mmHg (p = 0.001); between supine and sitting, it was 1.30 +/- 1.48 mmHg (p < 0.001); between ST and supine, it was -1.43 +/- 1.74 mmHg (p < 0.001); between ST-5 and supine, it was -0.77 +/- 1.59 mmHg (p < 0.001); between prone and supine, it was 2.24 +/- 1.92 mmHg (p < 0.001); between ST and ST-5, it was -0.67 +/- 1.84 mmHg (range: -7.5 to 5 mmHg) (p = 0.007); between prone and ST, it was 3.46 +/- 2.01 mmHg (p < 0.001); between ST-5 and prone, it was -2.46 +/- 1.67 mmHg (p < 0.001); and between sitting and prone, it was -3.22 +/- 1.56 mmHg (p < 0.001). The results show a significant IOP increase in the ST-5 position, suggesting that such measurements need to be performed in an attempt to explain the progression of glaucoma in apparently normal-tension patients.
引用
收藏
页数:13
相关论文
共 38 条
[1]   The influence of altitude on the differences between Goldmann tonometry and Pascal dynamic contour tonometry: An ecological meta-analysis [J].
Albis-Donado, Oscar ;
Ramirez-Neria, Paulina ;
Rios-Acosta, Nadia ;
Stalmans, Ingeborg .
INDIAN JOURNAL OF OPHTHALMOLOGY, 2024, 72 (SUPPL 3) :S398-S403
[2]   Comparison of Three Tonometers in Measuring Intraocular Pressure in Eyes That Underwent Myopic Laser in situ Keratomileusis and Photorefractive Keratectomy [J].
Ang, Robert Edward T. ;
Bargas, Neiman Vincent R. ;
Martinez, Gladness Henna A. ;
Sosuan, George Michael N. ;
Nabor-Umali, Maria Isabel .
CLINICAL OPHTHALMOLOGY, 2022, 16 :1623-1637
[3]  
Asrani S, 2000, J GLAUCOMA, V9, P134
[4]   Measurement of the difference in intraocular pressure between the sitting and lying body positions in healthy subjects: direct comparison of the Icare Pro with the Goldmann applanation tonometer, Pneumatonometer and Tonopen XL [J].
Barkana, Yaniv ;
Gutfreund, Shay .
CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2014, 42 (07) :608-614
[5]   Postural Change in Intraocular Pressure: A Comparison of Measurement With a Goldmann Tonometer, Tonopen XL, Pneumatonometer, and HA-2 [J].
Barkana, Yaniv .
JOURNAL OF GLAUCOMA, 2014, 23 (01) :E23-E28
[6]   Prospective Comparative Analysis of 4 Different Intraocular Pressure Measurement Techniques and Their Effects on Pressure Readings [J].
Berk, Thomas A. ;
Yang, Patrick T. ;
Chan, Clara C. .
JOURNAL OF GLAUCOMA, 2016, 25 (10) :E897-E904
[7]   Effect of Sleeping in a Head-Up Position on Intraocular Pressure in Patients with Glaucoma [J].
Buys, Yvonne M. ;
Alasbali, Tariq ;
Jin, Ya-Ping ;
Smith, Michael ;
Gouws, Pieter ;
Geffen, Noa ;
Flanagan, John G. ;
Shapiro, Colin M. ;
Trope, Graham E. .
OPHTHALMOLOGY, 2010, 117 (07) :1348-1351
[8]   Intraocular pressure fluctuation - A risk factor for visual field progression at low intraocular pressures in the advanced glaucoma intervention study [J].
Caprioli, Joseph ;
Coleman, Anne L. .
OPHTHALMOLOGY, 2008, 115 (07) :1123-1129
[9]   Intraocular pressure fluctuation - An independent risk factorfor glaucoma? [J].
Caprioli, Joseph .
ARCHIVES OF OPHTHALMOLOGY, 2007, 125 (08) :1124-1125
[10]   Comparability of three intraocular pressure measurement: iCare pro rebound, non-contact and Goldmann applanation tonometry in different IOP group [J].
Chen, Min ;
Zhang, Lina ;
Xu, Jia ;
Chen, Xinyi ;
Gu, Yuxiang ;
Ren, Yuping ;
Wang, Kaijun .
BMC OPHTHALMOLOGY, 2019, 19 (01)