Establishing reference intervals for thiamine pyrophosphate and pyridoxal 5'-phosphate in whole blood in a Danish cohort using liquid chromatography tandem-mass spectrometry (LC-ms/ms)

被引:0
作者
Stidsen, Nicoline Munch [1 ]
Bjerg, Lise Norkjaer [2 ]
Sandfeld-Paulsen, Birgitte [1 ,2 ]
机构
[1] Aarhus Univ, Dept Clin Med, Aarhus, Denmark
[2] Viborg Reg Hosp, Dept Clin Biochem, Viborg, Denmark
关键词
Thiamine pyrophosphate; vitamin B1; pyridoxal 5'-phosphate; vitamin B6; reference interval; whole blood; liquid chromatography tandem-mass spectrometry; VITAMIN-B-6; PERFORMANCE; PLASMA; SERUM;
D O I
10.1080/00365513.2024.2392126
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Vitamin B1 (thiamine pyrophosphate (TPP)) and B6 (pyridoxal 5'- phosphate (PLP)) deficiencies pose significant health risks. The current measurement method employs High-Performance Liquid Chromatography (HPLC), though, Liquid Chromatography with tandem Mass Spectrometry (LC-MS/MS) is considered a more sensitive and selective analytical method. However, there is a lack of LC-MS/MS-based reference intervals. Moreover, none of the existing reference intervals are established in Danish populations. Therefore, the aim of this study was to establish a reference interval for whole blood concentrations of TPP and PLP in Danish blood donors using LC-MS/MS. Blood samples were collected from healthy Danish blood donors and analysed using the reagent kit, MassChrom (R) Vitamins B1 and B6 in whole blood (Chromsystems Instruments & Chemicals GmbH, Munich, Germany) for quantitative determination of both TPP and PLP concentration in whole blood, using LC-MS/MS. Reference intervals were determined with non-parametric methods as the 2.5th and 97.5th percentile and presented with 90% confidence intervals (CI). In total 120 blood donors were included. The concentrations of TTP or PLP were not statistically different between sexes just as age did not affect the concentrations, hence, combined reference intervals were employed. The resulting reference intervals are: TPP, nmol/L: 101.0 (90% CI: 96.4-108.5) - 189.0 (90% CI: 184.7-192.0) and PLP, nmol/L: 64.0 (90% CI: 60.9-66.7) - 211.8 (90% CI: 168.3-231.0). In conclusion, reference intervals for whole blood TTP and PLP in a healthy Danish population were established based on a LC-MS/MS method. Furthermore, the reference intervals were not affected by age or sex.
引用
收藏
页码:311 / 316
页数:6
相关论文
共 22 条
[1]   Vitamin status in morbidly obese patients: a cross-sectional study [J].
Aasheim, Erlend T. ;
Hofso, Dag ;
Hjelmesaeth, Joran ;
Birkeland, Kare I. ;
Bohmer, Thomas .
AMERICAN JOURNAL OF CLINICAL NUTRITION, 2008, 87 (02) :362-369
[2]   Thiamine assay values: influence of anticoagulants and haemoglobin [J].
Aasheim, Erlend Tuseth ;
Hove, Anne Birgitte ;
Bohmer, Thomas .
SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 2009, 69 (04) :460-461
[3]  
[Anonymous], 2008, DEFINING ESTABLISHIN
[4]   Mitochondrial function and toxicity: Role of the B vitamin family on mitochondrial energy metabolism [J].
Depeint, Flore ;
Bruce, W. Robert ;
Shangari, Nandita ;
Mehta, Rhea ;
O'Brien, Peter J. .
CHEMICO-BIOLOGICAL INTERACTIONS, 2006, 163 (1-2) :94-112
[5]   Vitamin B1 interpretation: Erroneous higher levels in non-anemic populations [J].
Evliyaoglu, Osman ;
van Heiden, Josef ;
Imohl, Matthias ;
Weiskirchen, Ralf .
NUTRITION, 2019, 60 :25-29
[6]   Mining the Age-Dependent Reference Intervals of B Vitamins from Routine Laboratory Test Results [J].
Evliyaoglu, Osman ;
van Helden, Josef ;
Imoehl, Matthias ;
Weiskirchen, Ralf .
LABORATORY MEDICINE, 2019, 50 (01) :54-63
[7]   Vitamin B6: A Molecule for Human Health? [J].
Hellmann, Hanjo ;
Mooney, Sutton .
MOLECULES, 2010, 15 (01) :442-459
[8]   Vitamin B1 and B6 method harmonization: Comparison of performance between laboratories enrolled in the RCPA Quality Assurance Program [J].
Hoad, Kirsten E. ;
Johnson, Lambro A. ;
Woollard, Gerald A. ;
Walmsley, Trevor A. ;
Briscoe, Scott ;
Jolly, Lisa M. ;
Gill, Janice P. ;
Greaves, Ronda F. .
CLINICAL BIOCHEMISTRY, 2013, 46 (09) :772-776
[9]  
Ihara H., 2007, SIMPLIFIED HPLC METH
[10]  
Immunologi DSfK, 2021, REGLER TAPPEPAUSER