Peripheral Neural Synchrony in Postlingually Deafened Adult Cochlear Implant Users

被引:0
作者
He, Shuman [1 ,2 ]
Skidmore, Jeffrey [1 ]
Bruce, Ian C. [3 ]
Oleson, Jacob J. [4 ]
Yuan, Yi [1 ]
机构
[1] Ohio State Univ, Dept Otolaryngol Head & Neck Surg, Columbus, OH USA
[2] Nationwide Childrens Hosp, Dept Audiol, Columbus, OH USA
[3] McMaster Univ, Dept Elect & Comp Engn, Hamilton, ON, Canada
[4] Univ Iowa, Dept Biostat, Iowa City, IA USA
基金
加拿大自然科学与工程研究理事会; 美国国家卫生研究院;
关键词
Cochlear implants; Cochlear nerve; Neural synchrony; Speech perception; Temporal resolution acuity; SENSORINEURAL HEARING-LOSS; STIMULATED AUDITORY-NERVE; ELECTRICAL-STIMULATION; SPIRAL GANGLION; NEURONAL DEGENERATION; PATTERNS; RESPONSES; FIBERS; SYSTEM; HISTOPATHOLOGY;
D O I
10.1097/AUD.0000000000001502
中图分类号
R36 [病理学]; R76 [耳鼻咽喉科学];
学科分类号
100104 ; 100213 ;
摘要
Objectives:This paper reports a noninvasive method for quantifying neural synchrony in the cochlear nerve (i.e., peripheral neural synchrony) in cochlear implant (CI) users, which allows for evaluating this physiological phenomenon in human CI users for the first time in the literature. In addition, this study assessed how peripheral neural synchrony was correlated with temporal resolution acuity and speech perception outcomes measured in quiet and in noise in postlingually deafened adult CI users. It tested the hypothesis that peripheral neural synchrony was an important factor for temporal resolution acuity and speech perception outcomes in noise in postlingually deafened adult CI users.Design:Study participants included 24 postlingually deafened adult CI users with a Cochlear (TM) Nucleus (R) device. Three study participants were implanted bilaterally, and each ear was tested separately. For each of the 27 implanted ears tested in this study, 400 sweeps of the electrically evoked compound action potential (eCAP) were measured at four electrode locations across the electrode array. Peripheral neural synchrony was quantified at each electrode location using the phase-locking value (PLV), which is a measure of trial-by-trial phase coherence among eCAP sweeps/trials. Temporal resolution acuity was evaluated by measuring the within-channel gap detection threshold (GDT) using a three-alternative, forced-choice procedure in a subgroup of 20 participants (23 implanted ears). For each ear tested in these participants, GDTs were measured at two electrode locations with a large difference in PLVs. For 26 implanted ears tested in 23 participants, speech perception performance was evaluated using consonant-nucleus-consonant (CNC) word lists presented in quiet and in noise at signal to noise ratios (SNRs) of +10 and +5 dB. Linear Mixed effect Models were used to evaluate the effect of electrode location on the PLV and the effect of the PLV on GDT after controlling for the stimulation level effects. Pearson product-moment correlation tests were used to assess the correlations between PLVs, CNC word scores measured in different conditions, and the degree of noise effect on CNC word scores.Results:There was a significant effect of electrode location on the PLV after controlling for the effect of stimulation level. There was a significant effect of the PLV on GDT after controlling for the effects of stimulation level, where higher PLVs (greater synchrony) led to lower GDTs (better temporal resolution acuity). PLVs were not significantly correlated with CNC word scores measured in any listening condition or the effect of competing background noise presented at an SNR of +10 dB on CNC word scores. In contrast, there was a significant negative correlation between the PLV and the degree of noise effect on CNC word scores for a competing background noise presented at an SNR of +5 dB, where higher PLVs (greater synchrony) correlated with smaller noise effects on CNC word scores.Conclusions:This newly developed method can be used to assess peripheral neural synchrony in CI users, a physiological phenomenon that has not been systematically evaluated in electrical hearing. Poorer peripheral neural synchrony leads to lower temporal resolution acuity and is correlated with a larger detrimental effect of competing background noise presented at an SNR of 5 dB on speech perception performance in postlingually deafened adult CI users.
引用
收藏
页码:1125 / 1137
页数:13
相关论文
共 80 条
[11]   EEGLAB: an open source toolbox for analysis of single-trial EEG dynamics including independent component analysis [J].
Delorme, A ;
Makeig, S .
JOURNAL OF NEUROSCIENCE METHODS, 2004, 134 (01) :9-21
[12]   Assessing the Electrode-Neuron Interface with the Electrically Evoked Compound Action Potential, Electrode Position, and Behavioral Thresholds [J].
Devries, Lindsay ;
Scheperle, Rachel ;
Bierer, Julie Arenberg .
JARO-JOURNAL OF THE ASSOCIATION FOR RESEARCH IN OTOLARYNGOLOGY, 2016, 17 (03) :237-252
[13]   Spiral Ganglions and Speech Perception in the Elderly. Which Turn of the Cochlea is the More Relevant? A Preliminary Study on Human Temporal Bones [J].
Di Stadio, Arianna ;
della Volpe, Antonio ;
Ralli, Massimo ;
Korsch, Fiammetta ;
Greco, Antonio ;
Ricci, Giampietro .
JOURNAL OF INTERNATIONAL ADVANCED OTOLOGY, 2020, 16 (03) :318-322
[14]   Speech Perception Performance in Cochlear Implant Recipients Correlates to the Number and Synchrony of Excited Auditory Nerve Fibers Derived From Electrically Evoked Compound Action Potentials [J].
Dong, Yu ;
Briaire, Jeroen J. ;
Stronks, H. Christiaan ;
Frijns, Johan H. M. .
EAR AND HEARING, 2023, 44 (02) :276-286
[15]   Unravelling the temporal properties of human eCAPs through an iterative deconvolution model [J].
Dong, Yu ;
Briaire, Jeroen J. ;
Biesheuvel, Jan Dirk ;
Stronks, H. Christiaan ;
Frijns, Johan H. M. .
HEARING RESEARCH, 2020, 395
[16]   Sentence Recognition in Quiet and Noise by Pediatric Cochlear Implant Users: Relationships to Spoken Language [J].
Eisenberg, Laurie S. ;
Fisher, Laurel M. ;
Johnson, Karen C. ;
Ganguly, Dianne Hammes ;
Grace, Thelma ;
Niparko, John K. .
OTOLOGY & NEUROTOLOGY, 2016, 37 (02) :E75-E81
[17]   Physiological effects of auditory nerve myelinopathy in chinchillas [J].
El-Badry, Mohamed M. ;
Ding, Da-lian ;
McFadden, Sandra L. ;
Eddins, Ann C. .
EUROPEAN JOURNAL OF NEUROSCIENCE, 2007, 25 (05) :1437-1446
[18]   COCHLEAR IMPLANTS - HISTOPATHOLOGIC FINDINGS RELATED TO PERFORMANCE IN 16 HUMAN TEMPORAL BONES [J].
FAYAD, J ;
LINTHICUM, FH ;
OTTO, SR ;
GALEY, FR ;
HOUSE, WF .
ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY, 1991, 100 (10) :807-811
[19]   Multichannel cochlear implants: Relation of histopathology to performance [J].
Fayad, Jose N. ;
Linthicum, Fred H., Jr. .
LARYNGOSCOPE, 2006, 116 (08) :1310-1320
[20]   Relationship between gap detection thresholds and loudness in cochlear-implant users [J].
Garadat, Soha N. ;
Pfingst, Bryan E. .
HEARING RESEARCH, 2011, 275 (1-2) :130-138