Peripheral Neural Synchrony in Postlingually Deafened Adult Cochlear Implant Users

被引:0
作者
He, Shuman [1 ,2 ]
Skidmore, Jeffrey [1 ]
Bruce, Ian C. [3 ]
Oleson, Jacob J. [4 ]
Yuan, Yi [1 ]
机构
[1] Ohio State Univ, Dept Otolaryngol Head & Neck Surg, Columbus, OH USA
[2] Nationwide Childrens Hosp, Dept Audiol, Columbus, OH USA
[3] McMaster Univ, Dept Elect & Comp Engn, Hamilton, ON, Canada
[4] Univ Iowa, Dept Biostat, Iowa City, IA USA
基金
加拿大自然科学与工程研究理事会; 美国国家卫生研究院;
关键词
Cochlear implants; Cochlear nerve; Neural synchrony; Speech perception; Temporal resolution acuity; SENSORINEURAL HEARING-LOSS; STIMULATED AUDITORY-NERVE; ELECTRICAL-STIMULATION; SPIRAL GANGLION; NEURONAL DEGENERATION; PATTERNS; RESPONSES; FIBERS; SYSTEM; HISTOPATHOLOGY;
D O I
10.1097/AUD.0000000000001502
中图分类号
R36 [病理学]; R76 [耳鼻咽喉科学];
学科分类号
100104 ; 100213 ;
摘要
Objectives:This paper reports a noninvasive method for quantifying neural synchrony in the cochlear nerve (i.e., peripheral neural synchrony) in cochlear implant (CI) users, which allows for evaluating this physiological phenomenon in human CI users for the first time in the literature. In addition, this study assessed how peripheral neural synchrony was correlated with temporal resolution acuity and speech perception outcomes measured in quiet and in noise in postlingually deafened adult CI users. It tested the hypothesis that peripheral neural synchrony was an important factor for temporal resolution acuity and speech perception outcomes in noise in postlingually deafened adult CI users.Design:Study participants included 24 postlingually deafened adult CI users with a Cochlear (TM) Nucleus (R) device. Three study participants were implanted bilaterally, and each ear was tested separately. For each of the 27 implanted ears tested in this study, 400 sweeps of the electrically evoked compound action potential (eCAP) were measured at four electrode locations across the electrode array. Peripheral neural synchrony was quantified at each electrode location using the phase-locking value (PLV), which is a measure of trial-by-trial phase coherence among eCAP sweeps/trials. Temporal resolution acuity was evaluated by measuring the within-channel gap detection threshold (GDT) using a three-alternative, forced-choice procedure in a subgroup of 20 participants (23 implanted ears). For each ear tested in these participants, GDTs were measured at two electrode locations with a large difference in PLVs. For 26 implanted ears tested in 23 participants, speech perception performance was evaluated using consonant-nucleus-consonant (CNC) word lists presented in quiet and in noise at signal to noise ratios (SNRs) of +10 and +5 dB. Linear Mixed effect Models were used to evaluate the effect of electrode location on the PLV and the effect of the PLV on GDT after controlling for the stimulation level effects. Pearson product-moment correlation tests were used to assess the correlations between PLVs, CNC word scores measured in different conditions, and the degree of noise effect on CNC word scores.Results:There was a significant effect of electrode location on the PLV after controlling for the effect of stimulation level. There was a significant effect of the PLV on GDT after controlling for the effects of stimulation level, where higher PLVs (greater synchrony) led to lower GDTs (better temporal resolution acuity). PLVs were not significantly correlated with CNC word scores measured in any listening condition or the effect of competing background noise presented at an SNR of +10 dB on CNC word scores. In contrast, there was a significant negative correlation between the PLV and the degree of noise effect on CNC word scores for a competing background noise presented at an SNR of +5 dB, where higher PLVs (greater synchrony) correlated with smaller noise effects on CNC word scores.Conclusions:This newly developed method can be used to assess peripheral neural synchrony in CI users, a physiological phenomenon that has not been systematically evaluated in electrical hearing. Poorer peripheral neural synchrony leads to lower temporal resolution acuity and is correlated with a larger detrimental effect of competing background noise presented at an SNR of 5 dB on speech perception performance in postlingually deafened adult CI users.
引用
收藏
页码:1125 / 1137
页数:13
相关论文
共 80 条
[1]   An Examination of Sources of Variability Across the Consonant-Nucleus-Consonant Test in Cochlear Implant Listeners [J].
Bierer, Julie Arenberg ;
Spindler, Eugene ;
Bierer, Steven M. ;
Wright, Richard .
TRENDS IN HEARING, 2016, 20
[2]  
Blamey P, 1996, Audiol Neurootol, V1, P293
[3]   Factors Affecting Auditory Performance of Postlinguistically Deaf Adults Using Cochlear Implants: An Update with 2251 Patients [J].
Blamey, Peter ;
Artieres, Franoise ;
Baskent, Deniz ;
Bergeron, Francois ;
Beynon, Andy ;
Burke, Elaine ;
Dillier, Norbert ;
Dowell, Richard ;
Fraysse, Bernard ;
Gallego, Stephane ;
Govaerts, Paul J. ;
Green, Kevin ;
Huber, Alexander M. ;
Kleine-Punte, Andrea ;
Maat, Bert ;
Marx, Mathieu ;
Mawman, Deborah ;
Mosnier, Isabelle ;
O'Connor, Alec Fitzgerald ;
O'Leary, Stephen ;
Rousset, Alexandra ;
Schauwers, Karen ;
Skarzynski, Henryk ;
Skarzynski, Piotr H. ;
Sterkers, Olivier ;
Terranti, Assia ;
Truy, Eric ;
Van de Heyning, Paul ;
Venail, Frederic ;
Vincent, Christophe ;
Lazard, Diane S. .
AUDIOLOGY AND NEURO-OTOLOGY, 2013, 18 (01) :36-47
[4]   AutoNRT™:: An automated system that measures ECAP thresholds with the Nucleus® Freedom™ cochlear implant via machine intelligence [J].
Botros, Andrew ;
van Dijk, Bas ;
Killian, Matthijs .
ARTIFICIAL INTELLIGENCE IN MEDICINE, 2007, 40 (01) :15-28
[5]   ELECTRICALLY EVOKED WHOLE-NERVE ACTION-POTENTIALS - DATA FROM HUMAN COCHLEAR IMPLANT USERS [J].
BROWN, CJ ;
ABBAS, PJ ;
GANTZ, B .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1990, 88 (03) :1385-1391
[6]  
Bruce I. C., 2013, Proc. Mtgs. Acoust, V19, P050178, DOI [10.1121/1.4799733, DOI 10.1121/1.4799733]
[7]   A stochastic model of the electrically stimulated auditory nerve: Single-pulse response [J].
Bruce, IC ;
White, MW ;
Irlicht, LS ;
O'Leary, SJ ;
Dynes, S ;
Javel, E ;
Clark, GM .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1999, 46 (06) :617-629
[8]   Gap detection by early-deafened cochlear-implant subjects [J].
Busby, PA ;
Clark, GM .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1999, 105 (03) :1841-1852
[9]   Adaptation of the electrically evoked compound action potential (ECAP) recorded from nucleus CI24 cochlear implant users [J].
Clay, Kelly M. Schmidt ;
Brown, Carolyn J. .
EAR AND HEARING, 2007, 28 (06) :850-861
[10]   SPEECH CODING IN THE AUDITORY-NERVE .1. VOWEL-LIKE SOUNDS [J].
DELGUTTE, B ;
KIANG, NYS .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1984, 75 (03) :866-878