A CFD study on the effect of portable air cleaner placement on airborne infection control in a classroom

被引:0
|
作者
Pei, Gen [1 ]
Azimi, Parham [1 ]
Rim, Donghyun [2 ]
Allen, Joseph G. [1 ]
机构
[1] Harvard TH Chan Sch Publ Hlth, Environm Hlth Dept, Boston, MA 02115 USA
[2] Penn State Univ, Architectural Engn Dept, University Pk, PA 16802 USA
关键词
INHALATION INTAKE FRACTION; SCHOOL ABSENTEEISM; VENTILATION RATE; HUMAN-BODY; INDOOR; POLLUTANTS; PARTICLES; TRANSMISSION; PARTICULATE; DISPERSION;
D O I
10.1039/d4em00114a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The utilization of portable air cleaners (PACs) is a recommended supplemental approach to help remove airborne pathogens and mitigate disease transmission in learning environments. To improve PAC effectiveness, science-based information is needed to optimize their implementation strategies such as the deployment location, height, and number of PACs. In this study, we developed a Computational Fluid Dynamics (CFD) model to assess how PACs perform in occupied classrooms equipped with displacement and mixing ventilation systems. The results show that PACs with a flow rate of 2.6 h(-1) reduce the mean aerosol intake of all students by up to 66%. A key benefit of using PACs is to facilitate air mixing and movement in indoor environments with inadequate ventilation, thereby effectively reducing high aerosol concentrations near the infector. Furthermore, our results highlight the impact of PAC location on its performance. PACs achieve the best effectiveness when placed closed to the infector (within a distance <3 m). In the absence of knowing who is infected, deploying a PAC at the center of the room is recommended. Moreover, adjusting PAC flow discharge height to the breathing height of occupants (e.g., 0.9-1.2 m for seated people) can enhance their effectiveness in spaces with poor air mixing.
引用
收藏
页码:1476 / 1488
页数:14
相关论文
共 19 条
  • [1] Indoor Air Quality Control for Airborne Diseases: A Review on Portable UV Air Purifiers
    Sankurantripati, Shriram
    Duchaine, Florent
    FLUIDS, 2024, 9 (12)
  • [2] Energy consumption of using HEPA-based portable air cleaner in residences: A monitoring study in Seattle, US
    Xiang, Jianbang
    Huang, Ching-Hsuan
    Austin, Elena
    Shirai, Jeff
    Liu, Yisi
    Seto, Edmund
    ENERGY AND BUILDINGS, 2021, 236
  • [3] Individual heterogeneity and airborne infection: Effect of non-uniform air distribution
    Jia, Wei
    Cheng, Pan
    Ma, Luping
    Wang, Shengqi
    Qian, Hua
    Li, Yuguo
    BUILDING AND ENVIRONMENT, 2022, 226
  • [4] Ventilation indices for evaluation of airborne infection risk control performance of air distribution
    Lu, Yalin
    Niu, Dun
    Zhang, Sheng
    Chang, Han
    Lin, Zhang
    BUILDING AND ENVIRONMENT, 2022, 222
  • [5] Control of wildfire-sourced PM2.5 in an office setting using a commercially available portable air cleaner
    Stauffer, Dylan A.
    Autenrieth, Daniel A.
    Hart, Julie F.
    Capoccia, Stella
    JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE, 2020, 17 (04) : 109 - 120
  • [6] The effect of portable HEPA filter air cleaner use during pregnancy on fetal growth: The UGAAR randomized controlled trial
    Barn, Prabjit
    Gombojav, Enkhjargal
    Ochir, Chimedsuren
    Boldbaatar, Buyantushig
    Beejin, Bolor
    Naidan, Gerel
    Galsuren, Jargalsaikhan
    Legtseg, Bayarkhuu
    Byambaa, Tsogtbaatar
    Hutcheon, Jennifer A.
    Janes, Craig
    Janssen, Patricia A.
    Lanphear, Bruce P.
    McCandless, Lawrence C.
    Takaro, Tim K.
    Venners, Scott A.
    Webster, Glenys M.
    Allen, Ryan W.
    ENVIRONMENT INTERNATIONAL, 2018, 121 : 981 - 989
  • [7] Impacts of using auto-mode portable air cleaner on indoor PM2.5 levels: An intervention study
    Huang, Ching-Hsuan
    Xiang, Jianbang
    Austin, Elena
    Shirai, Jeff
    Liu, Yisi
    Simpson, Christopher
    Karr, Catherine J.
    Fyfe-Johnson, Amber L.
    Larsen, Thomas Kronborg
    Seto, Edmund
    BUILDING AND ENVIRONMENT, 2021, 188
  • [8] CFD modelling of infection control in indoor environments: A focus on room-level air recirculation systems
    Xu, Shipeng
    Zhang, Guangwei
    Liu, Xiaoping
    Li, Xiaoping
    ENERGY AND BUILDINGS, 2023, 288
  • [9] Air Disinfection for Airborne Infection Control with a Focus on COVID-19: Why Germicidal UV is Essential†
    Nardell, Edward A.
    PHOTOCHEMISTRY AND PHOTOBIOLOGY, 2021, 97 (03) : 493 - 497
  • [10] A study on contaminant leakage from Airborne Infection Isolation room during medical staff entry; Implementation of walking motion on hypothetical human model in CFD simulation
    Jo, Seongmin
    Kim, Gihoon
    Sung, Minki
    JOURNAL OF BUILDING ENGINEERING, 2024, 86