Moderate-Flow Perfusion is Superior to Low-Flow Perfusion in Ex Situ Lung Perfusion

被引:1
|
作者
Forgie, Keir [1 ,2 ]
Fialka, Nicholas [1 ,2 ]
Watkins, Abeline [3 ]
Du, Katie [3 ]
Himmat, Sayed [4 ]
Hatami, Sanaz [4 ]
Khan, Mubashir [4 ]
Wang, Xiuhua [4 ]
Edgar, Ryan [5 ]
Buswell-Zuk, Katie-Marie [5 ]
Freed, Darren [1 ,2 ,6 ,7 ]
Nagendran, Jayan [1 ,2 ,6 ,7 ]
机构
[1] Univ Alberta, Div Cardiac Surg, Dept Surg, Fac Med, Edmonton, AB, Canada
[2] Mazankowski Alberta Heart Inst, 4-108A Li Ka Shing Hlth Res Ctr, T6G 2B7 Edmonton, AB, Canada
[3] Univ Alberta, Fac Med & Dent, Edmonton, AB, Canada
[4] Univ Alberta, Fac Med, Dept Surg, Edmonton, AB, Canada
[5] Ray Rajotte Surg Med Res Inst SMRI, Edmonton, AB, Canada
[6] Alberta Transplant Inst, Edmonton, AB, Canada
[7] Canadian Donat & Transplantat Res Program, Edmonton, AB, Canada
关键词
INTERNATIONAL SOCIETY; ADULT LUNG; TRANSPLANTATION; PRESERVATION; REGISTRY; HEART; MODEL;
D O I
10.1016/j.transproceed.2024.08.032
中图分类号
R392 [医学免疫学]; Q939.91 [免疫学];
学科分类号
100102 ;
摘要
Background Full-flow perfusion during prolonged ex situ lung perfusion (ESLP) results in unacceptable pulmonary edema formation. Clinical ESLP at 30% to 50% predicted cardiac output (CO) supports acceptable physiologic outcomes; however, progressive pulmonary edema still develops. Lower flow rates may provide equivalent physiologic preservation with less edema formation due to reduced hydrostatic pressures. We report our results of moderate-flow (MF; 30% CO) vs low-flow (LF; 10% CO) negative pressure ventilation (NPV)-ESLP with transplantation. Methods Twelve pig lungs underwent 12-hours of NPV-ESLP with 30% or 10% CO (n = 6/group). Three left lungs per group were transplanted post-ESLP and assessed in vivo over 4 hours. Lung function was assessed by physiologic parameters, weight-gain, and pro-inflammatory cytokine profiles. Results Results are MF vs LF (mean +/- SEM). All lungs demonstrated acceptable oxygenation post-ESLP (454.2 +/- 40.85 vs 422.7 +/- 31.68, P = .28); however, after transplantation, the MF lungs demonstrated significantly better oxygenation (300.7 +/- 52.26 vs 141.9 +/- 36.75, P = .03). There was no significant difference in compliance after ESLP (21.38 +/- 2.28 vs 16.48 +/- 2.34, P = .08); however, pulmonary artery pressure (PAP; 10.89 +/- 2.28 vs 21.11 +/- 0.93, P = .06) and pulmonary vascular resistance (PVR; 438.60 +/- 97.97 vs 782.20 +/- 162.20, P = .05) were significantly higher in the LF group. Weight gain (%) post-ESLP and post-transplant was similar between groups (29.42 +/- 5.72 vs 24.17 +/- 4.42, P = .24; and 29.63 +/- 7.23 vs 57.04 +/- 15.78, P = .09). TNF-alpha and IL-6 were significantly greater throughout LF ESLP. Conclusions The MF NPV-ESLP results in superior lung function with less inflammation compared to LF NPV-ESLP.
引用
收藏
页码:1820 / 1827
页数:8
相关论文
共 50 条
  • [1] Ex vivo lung perfusion
    Machuca, Tiago N.
    Cypel, Marcelo
    JOURNAL OF THORACIC DISEASE, 2014, 6 (08) : 1054 - 1062
  • [2] Extracorporeal lung perfusion (ex-vivo lung perfusion)
    Cypel, Marcelo
    Keshavjee, Shaf
    CURRENT OPINION IN ORGAN TRANSPLANTATION, 2016, 21 (03) : 329 - 335
  • [3] Low-Flow Hypothermic Crystalloid Perfusion Is Superior to Cold Storage During Prolonged Heart Preservation
    Ou, R.
    Lim, Y. W.
    Choong, J. W.
    Esmore, D. S.
    Salamonsen, R. F.
    McLean, C.
    Forbes, J.
    Bailey, M.
    Rosenfeldt, F. L.
    TRANSPLANTATION PROCEEDINGS, 2014, 46 (10) : 3309 - 3313
  • [4] Ex-vivo lung perfusion
    Van Raemdonck, Dirk
    Neyrinck, Arne
    Cypel, Marcelo
    Keshavjee, Shaf
    TRANSPLANT INTERNATIONAL, 2015, 28 (06) : 643 - 656
  • [5] Ex vivo lung perfusion
    Rajab, Taufiek Konrad
    Keshavjee, Shaf
    ARTIFICIAL ORGANS, 2020, 44 (01) : 12 - 15
  • [6] The evaluation of constant coronary artery flow versus constant coronary perfusion pressure during normothermic ex situ heart perfusion
    Qi, Xiao
    Hatami, Sanaz
    Bozso, Sabin
    Buchko, Max
    Forgie, Keir A.
    Olafson, Carly
    Khan, Mubashir
    Himmat, Sayed
    Wang, Xiuhua
    Nobes, David S.
    Acker, Jason P.
    Nagendran, Jayan
    Freed, Darren H.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2022, 41 (12): : 1738 - 1750
  • [7] An automated and portable low-flow pulsatile perfusion system for organ preservation
    Yland, MJ
    Todo, S
    Zhu, Y
    Suzuki, T
    Hamada, N
    Zhang, SM
    Subbotin, VM
    Doria, C
    Hikida, S
    Nemoto, A
    Venkataramanan, R
    Tata, P
    Bernardo, JF
    TRANSPLANT INTERNATIONAL, 1996, 9 (06) : 535 - 540
  • [8] Devices for ex vivo heart and lung perfusion
    Schraufnagel, Dean P.
    Steffen, Robert J.
    Vargo, Patrick R.
    Attia, Tamer
    Elgharably, Haytham
    Hasan, Saad M.
    Bribriesco, Alejandro
    Wierup, Per
    EXPERT REVIEW OF MEDICAL DEVICES, 2018, 15 (03) : 183 - 191
  • [9] Ex vivo lung graft perfusion
    Briot, Raphael
    Gennai, Stephane
    Maignan, Maxime
    Souilamas, Redha
    Pison, Christophe
    ANAESTHESIA CRITICAL CARE & PAIN MEDICINE, 2016, 35 (02) : 123 - 131
  • [10] Ex-vivo lung perfusion
    Garijo, Jacobo Moreno
    Roscoe, Andrew
    CURRENT OPINION IN ANESTHESIOLOGY, 2020, 33 (01) : 50 - 54