Robotic MR-guided high dose rate brachytherapy needle implantation in the prostate (ROBiNSon)-a proof-of-concept study

被引:0
作者
Rasing, Marnix J. A. [1 ]
van Schelven, Leonard J. [2 ]
van Lier, Astrid L. H. M. W. [1 ]
Boskovic, Ernest [2 ]
van Son, Marieke [3 ]
Schokker, Rogier, I [1 ]
van Vliet-van den Ende, Katelijne M. [1 ]
Kelder, Danielle D. [1 ]
Verkerk, Jacqueline [1 ]
van de Pol, Sandrine M. G. [1 ]
Lagendijk, Jan J. W. [1 ]
Peters, Max [1 ]
van Zyp, Jochem R. N. van der Voort [1 ]
Moerland, Marinus A. [1 ]
机构
[1] Univ Med Ctr Utrecht, Dept Radiat Oncol, Heidelberglaan 100, NL-3584 CX Utrecht, Netherlands
[2] Univ Med Ctr Utrecht, Dept Med Technol & Clin Phys, Heidelberglaan 100, NL-3584 CX Utrecht, Netherlands
[3] Univ Amsterdam, Univ Gen Practice, Med Ctr, De Boelelaan 1117, NL-1007 MB Amsterdam, Netherlands
关键词
MR-guided; robotic; brachytherapy; HDR; prostate cancer; INSERTION; CANCER; SYSTEM;
D O I
10.1088/1361-6560/ad69f8
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective. A robotic needle implant device for MR-guided high-dose-rate (HDR) prostate brachytherapy was developed. This study aimed to assess the feasibility and spatial accuracy of HDR brachytherapy using the robotic device, for a single intraprostatic target point. Approach. Five patients were treated from November 2019-June 2022 with the robot. The robot fits a 1.5 T MR scanner and the needle can be shifted and angulated. An intraprocedural MR scan was fused with the diagnostic MR and one preplanned needle position was selected for robotic insertion. The needle entry point and angles were set for a needle tip target point within the intraprostatic target volume. The needle was tapped stepwise towards the target point pneumatically. Final needle position was verified with MR, followed by plan optimization and dose delivery. Any remaining planned needles were inserted manually. Needle tip to geometrical target error (NTG-error) was defined as the deviation of the actual tip position relative to the predefined geometric target point, using MR-coordinates. Needle tip to treatment target error (NTT-error) was defined as the deviation of the actual tip position relative to the treatment target point, using fused MR-images pre- and post-needle implantation taking into account prostate deformation. Difference between NTT-error and NTG-error and fiducial marker shifts indicated prostate movement. For determining prostate deformation, the Jaccard index and prostate volumes were assessed. Main results. The robotic device was able to tap the needle to the planned depth for all patients. Mean robotic procedure duration was 142 min. NTG-error was 3.2 (range 1.1-6.7) mm and NTT-error 4.5 (range 2.6-9.6) mm. Marker displacements were smaller than 3 mm. No treatment-related acute toxicity was reported. Feasibility of needle placement within the prostate was considered adequate. Significance. MR-guided robotic needle insertion is feasible with a mean geometric accuracy of 3.2 mm and <3 mm prostate movement.
引用
收藏
页数:14
相关论文
共 35 条
  • [1] Preliminary Study of a Modular MR-Compatible Robot for Image-Guided Insertion of Multiple Needles
    Aleong, Amanda M.
    Looi, Thomas
    Luo, Kevin
    Zou, Zhiling
    Waspe, Adam
    Singh, Satwinder
    Drake, James M.
    Weersink, Robert A.
    [J]. FRONTIERS IN ONCOLOGY, 2022, 12
  • [2] [Anonymous], European Union 2017 Regulation (EU) 2017/745 of 5 April 2017 on medical devices, amendingDirective2001/83/EC,Regulation(EC)No178/2002andRegulation(EC)No1223/2009andrepealingCouncilDirectives90/385/EECand93/42/EEC
  • [3] In-Bore Transrectal MRI-Guided Biopsy With Robotic Assistance in the Diagnosis of Prostate Cancer: An Analysis of 57 Patients
    Barral, Matthias
    Lefevre, Arnaud
    Camparo, Philippe
    Hoogenboom, Martijn
    Pierre, Thibaut
    Soyer, Philippe
    Cornud, Francois
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2019, 213 (04) : W171 - W179
  • [4] Mechatronic system for in-bore MRI-guided insertion of needles to the prostate: An in vivo needle guidance accuracy study
    Cepek, Jeremy
    Lindner, Uri
    Ghai, Sangeet
    Louis, Alyssa S.
    Davidson, Sean R. H.
    Gertner, Mark
    Hlasny, Eugen
    Sussman, Marshall S.
    Fenster, Aaron
    Trachtenberg, John
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2015, 42 (01) : 48 - 55
  • [5] Prostate volume changes during permanent seed brachytherapy: an analysis of intra-operative variations, predictive factors and clinical implication
    Chira, Ciprian
    Delouya, Guila
    Larrivee, Sandra
    Carrier, Jean-Francois
    Taussky, Daniel
    [J]. RADIATION ONCOLOGY, 2013, 8
  • [6] Prospective Clinical Implementation of a Novel Magnetic Resonance Tracking Device for Real-Time Brachytherapy Catheter Positioning
    de Arcos, Jose
    Schmidt, Ehud J.
    Wang, Wei
    Tokuda, Junichi
    Vij, Kamal
    Seethamraju, Ravi T.
    Damato, Antonio L.
    Dumoulin, Charles L.
    Cormack, Robert A.
    Viswanathan, Akila N.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2017, 99 (03): : 618 - 626
  • [7] Review of Clinical and Technological Consideration for MRI-Guided Robotic Prostate Brachytherapy
    Dhaliwal, Sepaldeep Singh
    Chettibi, Taha
    Wilby, Sarah
    Polak, Wojciech
    Palmer, Antony L.
    Reynaert, Nick
    Merzouki, Rochdi
    [J]. IEEE TRANSACTIONS ON MEDICAL ROBOTICS AND BIONICS, 2021, 3 (03): : 583 - 605
  • [8] High-Field Open versus Short-Bore Magnetic Resonance Imaging of the Spine: A Randomized Controlled Comparison of Image Quality
    Enders, Judith
    Rief, Matthias
    Zimmermann, Elke
    Asbach, Patrick
    Diederichs, Gerd
    Wetz, Christoph
    Siebert, Eberhard
    Wagner, Moritz
    Hamm, Bernd
    Dewey, Marc
    [J]. PLOS ONE, 2013, 8 (12):
  • [9] Robot-assisted MRI-guided prostatic interventions
    Goldenberg, Andrew A.
    Trachtenberg, John
    Yi, Yang
    Weersink, Robert
    Sussman, Marshall S.
    Haider, Masoom
    Ma, Liang
    Kucharczyk, Walter
    [J]. ROBOTICA, 2010, 28 : 215 - 234
  • [10] Risk-adaptive paradigm for focal versus whole-gland salvage treatment for radio-recurrent prostate cancer
    King, Martin T.
    Yang, David D.
    D'Amico, Anthony, V
    Buzurovic, Ivan
    Harris, Thomas C.
    Guthier, Christian, V
    Steele, Graeme S.
    Kathrins, Martin N.
    Choudhury, Atish D.
    [J]. FRONTIERS IN ONCOLOGY, 2022, 12