A multianalyte LC-MS/MS method for accurate quantification of Nitrosamines in Olmesartan tablets

被引:2
|
作者
Pawar, Namdev [1 ]
Bhardwaj, Aparna [1 ]
Vora, Amisha [2 ]
Sharma, Sanjay [3 ]
机构
[1] Chauhan Inst Sci & Amrutben Jivanlal Coll Commerce, Mithibai Coll Arts, Dept Chem, Vile Parle West, Mumbai 400056, India
[2] NMIMS, Shobhaben Pratapbhai Patel Sch Pharm & Technol Man, Dept Chem, Vile Parle West, Mumbai 400056, India
[3] NMIMS, Shobhaben Pratapbhai Patel Sch Pharm & Technol Man, Dept Qual Assurance, Vile Parle West, Mumbai 400056, India
关键词
Olmesartan; Nitrosamines; LC-MS/MS; Analysis; QUANTITATIVE-DETERMINATION; PHARMACEUTICAL PRODUCTS; HUMAN PLASMA; RP-HPLC; HYDROCHLOROTHIAZIDE; MEDOXOMIL; AMLODIPINE; URINE; NDMA;
D O I
10.1016/j.chroma.2024.465176
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This research summaries the development, optimization and validation of liquid chromatography tandem mass spectrometric (LC-MS/MS) method for concurrent measurement of seven nitrosamines viz; NDMA, NDEA, NDIPA, NDPA, NEIPA, NMPA & NMBA in Olmesartan tablet. Controlling these nitrosamines at trace levels is imperative for ensuring the safety of drug substances and products for consumption. Various regulatory authorities stress the significance of utilizing highly sensitive analytical methods to precisely measure nitrosamines at trace levels. The method applied effective chromatographic separation and optimized parameters for mass spectrometric detection. Detection was carried out using APCI positive ion mode. Chromatographic separation was achieved using a Thermo Accucore PFP column (150 mm x 4.6 mm, 2.6 mu), with a simple gradient elution of mobile phase consisting of 0.1 % formic acid in water (mobile phase A) and methanol (mobile phase B). The total run time was 20 min, with a flow rate of 0.800 mL/min. The method was validated according to the International Council on Harmonisation (ICH Q2 (R2)) guidelines. The established method demonstrated excellent linearity (R-2> 0.99) and sensitivity for all the nitrosamines. Detection and quantification limits were sufficiently low for trace nitrosamine levels having good S/N ratio. The method showed good accuracy in Olmesartan tablet samples, with recoveries ranges between 80 % to 120 %. The new analytical approach has exceptional repeatability and reliability, making it possible to precisely quantify the levels of seven nitrosamines in Olmesartan medoxomil tablets in a single analytical run.
引用
收藏
页数:13
相关论文
共 50 条
  • [41] Development and validation of an LC-MS/MS method for quantification of favipiravir in human plasma
    Challenger, Elizabeth
    Penchala, Sujan Dilly
    Hale, Colin
    Fitzgerald, Richard
    Walker, Lauren
    Reynolds, Helen
    Chiong, Justin
    Fletcher, Tom
    Khoo, Saye
    Else, Laura
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2023, 233
  • [42] Development of the quantification method of antibody concentration in tissues using LC-MS/MS
    Fuchigami, Hirobumi
    Koganemaru, Shigehiro
    Yasunaga, Masahiro
    CANCER SCIENCE, 2023, 114 : 1497 - 1497
  • [43] An LC-MS/MS Method Development and Validation for the Quantification of Abametapir in Plasma Samples
    Sankar, Palakollu D. S.
    Panigrahi, Naresh
    SEPARATION SCIENCE PLUS, 2025, 8 (01):
  • [44] Quantification of vancomycin in human serum by LC-MS/MS
    Koenig, Katrin
    Kobold, Uwe
    Fink, Gerhard
    Leinenbach, Andreas
    Duelffer, Thomas
    Thiele, Roland
    Zander, Johannes
    Vogeser, Michael
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2013, 51 (09) : 1761 - 1769
  • [45] A sensitive and rapid method for quantification of lacosamide and desmethyl lacosamide by LC-MS/MS
    Payto, Drew
    Foldvary-Schaefer, Nancy
    So, Norman
    Bruton, Monica
    Wang, Sihe
    BIOANALYSIS, 2014, 6 (23) : 3161 - 3168
  • [46] Quantification of metronidazole in healthy subjects' feces using an LC-MS/MS method
    Vanol, Pravin G.
    Sanyal, Mallika
    Shah, Priyanka A.
    Shrivastav, Pranav S.
    BIOMEDICAL CHROMATOGRAPHY, 2018, 32 (09)
  • [47] Fast and Simple LC-MS/MS Method for Rifampicin Quantification in Human Plasma
    Rakusa, Zane Temova
    Roskar, Robert
    Andrejc, Anita Klancar
    Lusin, Tina Trdan
    Faganeli, Natasa
    Grabnar, Iztok
    Mrhar, Ales
    Kristl, Albin
    Trontelj, Jurij
    INTERNATIONAL JOURNAL OF ANALYTICAL CHEMISTRY, 2019, 2019
  • [48] An LC-MS/MS method for the simultaneous quantification of 32 steroids in human plasma
    Simkova, Marketa
    Kolatorova, Lucie
    Drasar, Pavel
    Vitku, Jana
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2022, 1201
  • [49] Development and clinical validation of an LC-MS/MS method for the quantification of pazopanib in DBS
    Verheijen, Remy B.
    Bins, Sander
    Thijssen, Bas
    Rosing, Hilde
    Nan, Lianda
    Schellens, Jan H. M.
    Mathijssen, Ron H. J.
    Lolkema, Martijn P.
    Beijnen, Jos H.
    Steeghs, Neeltje
    Huitema, Alwin D. R.
    BIOANALYSIS, 2016, 8 (02) : 123 - 134
  • [50] An LC-MS/MS-ESI Method for the Quantification of Betamethasone in Bioequivalence Studies
    Teixeira, L. S.
    Mundim, I. M.
    Souza, W. C.
    Ramos, D. R.
    Bellorio, K. B.
    Rezende, K. R.
    ACTA CHROMATOGRAPHICA, 2011, 23 (03): : 415 - 428