A multianalyte LC-MS/MS method for accurate quantification of Nitrosamines in Olmesartan tablets

被引:2
|
作者
Pawar, Namdev [1 ]
Bhardwaj, Aparna [1 ]
Vora, Amisha [2 ]
Sharma, Sanjay [3 ]
机构
[1] Chauhan Inst Sci & Amrutben Jivanlal Coll Commerce, Mithibai Coll Arts, Dept Chem, Vile Parle West, Mumbai 400056, India
[2] NMIMS, Shobhaben Pratapbhai Patel Sch Pharm & Technol Man, Dept Chem, Vile Parle West, Mumbai 400056, India
[3] NMIMS, Shobhaben Pratapbhai Patel Sch Pharm & Technol Man, Dept Qual Assurance, Vile Parle West, Mumbai 400056, India
关键词
Olmesartan; Nitrosamines; LC-MS/MS; Analysis; QUANTITATIVE-DETERMINATION; PHARMACEUTICAL PRODUCTS; HUMAN PLASMA; RP-HPLC; HYDROCHLOROTHIAZIDE; MEDOXOMIL; AMLODIPINE; URINE; NDMA;
D O I
10.1016/j.chroma.2024.465176
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This research summaries the development, optimization and validation of liquid chromatography tandem mass spectrometric (LC-MS/MS) method for concurrent measurement of seven nitrosamines viz; NDMA, NDEA, NDIPA, NDPA, NEIPA, NMPA & NMBA in Olmesartan tablet. Controlling these nitrosamines at trace levels is imperative for ensuring the safety of drug substances and products for consumption. Various regulatory authorities stress the significance of utilizing highly sensitive analytical methods to precisely measure nitrosamines at trace levels. The method applied effective chromatographic separation and optimized parameters for mass spectrometric detection. Detection was carried out using APCI positive ion mode. Chromatographic separation was achieved using a Thermo Accucore PFP column (150 mm x 4.6 mm, 2.6 mu), with a simple gradient elution of mobile phase consisting of 0.1 % formic acid in water (mobile phase A) and methanol (mobile phase B). The total run time was 20 min, with a flow rate of 0.800 mL/min. The method was validated according to the International Council on Harmonisation (ICH Q2 (R2)) guidelines. The established method demonstrated excellent linearity (R-2> 0.99) and sensitivity for all the nitrosamines. Detection and quantification limits were sufficiently low for trace nitrosamine levels having good S/N ratio. The method showed good accuracy in Olmesartan tablet samples, with recoveries ranges between 80 % to 120 %. The new analytical approach has exceptional repeatability and reliability, making it possible to precisely quantify the levels of seven nitrosamines in Olmesartan medoxomil tablets in a single analytical run.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] A rapid LC-MS/MS method for multi-class identification and quantification A rapid LC-MS/MS method for multi-class identification and quantification of cyanotoxins of cyanotoxins
    Jacinavicius, Fernanda Rios
    Campos, Thaissa Giovanna Valverde
    Passos, Larissa Souza
    Pinto, Ernani
    Geraldes, Vanessa
    TOXICON, 2023, 234
  • [22] Quantification of Alfacalcidol Tablets Dissolution Content by Chemical Derivatization and LC-MS
    Liu, Yang
    Chen, Xi
    Yuan, Song
    Liu, Wanhui
    He, Lan
    Zhang, Qingsheng
    JOURNAL OF ANALYTICAL METHODS IN CHEMISTRY, 2020, 2020
  • [23] Quantification of nivolumab in human plasma by LC-MS/HRMS and LC-MS/MS, comparison with ELISA
    Millet, Aurelien
    Khoudour, Nihel
    Bros, Pauline
    Lebert, Dorothee
    Picard, Guillaume
    Machon, Christelle
    Goldwasser, Francois
    Blanchet, Benoit
    Guitton, Jerome
    TALANTA, 2021, 224
  • [24] Matrix effect marker for multianalyte analysis by LC-MS/MS in biological samples
    Tudela, Eva
    Munoz, Gloria
    Munoz-Guerra, Jesus A.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2012, 901 : 98 - 106
  • [25] Development of a sensitive LC-MS/MS method for simultaneous determination of three nitrosamines in losartan API and assessment of nitrosamines formation
    Carlos, Graciela
    Martini, Paulo R. R.
    Machioli, Lilian F.
    Garcia, Cassia, V
    Paim, Clesio S.
    de Oliveira, Tiago Franco
    Mendez, Andreas S. L.
    MICROCHEMICAL JOURNAL, 2025, 208
  • [26] LC-MS Method for the Quantification of Clonazepam in Rat Plasma
    Gu, Jifeng
    Chen, Nianzu
    Yan, Jingchao
    Huang, Taomin
    Wang, Donglei
    Lai, Yonghua
    CHROMATOGRAPHIA, 2009, 70 (11-12) : 1709 - 1713
  • [27] Serum Pharmacochemistry Study of Sanhuang Tablets by LC-MS/MS
    Li, Yanru
    Wang, Yilin
    Tang, Ling
    Wang, Yan
    LATIN AMERICAN JOURNAL OF PHARMACY, 2021, 40 (05): : 1036 - 1044
  • [28] QUANTIFICATION OF PHENYLALANINE HYDROXYLASE ACTIVITY BY LC-MS/MS
    Heintz, C.
    Troxler, H.
    Martinez, A.
    Thoeny, B.
    Blau, N.
    JOURNAL OF INHERITED METABOLIC DISEASE, 2011, 34 : S94 - S94
  • [29] A simple LC-MS/MS method for the simultaneous quantification of drug metabolic enzymes
    Guo, Xuan
    Zhang, Lei
    Lei, Zihan
    Hou, Zhe
    Li, Hui
    Li, Xiaodong
    Dong, Jing
    Song, Ling
    Chen, Dingding
    Liu, Dongyang
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2023, 1214
  • [30] Development of an LC-MS/MS method for the quantification of goserelin from Pheroid® formulation
    Takyi-Williams, John
    Erasmus, Linne
    Magwaza, Martin
    Hayeshi, Rose
    Grobler, Anne
    JOURNAL OF PHARMACOLOGICAL AND TOXICOLOGICAL METHODS, 2019, 98