Enhancing thermodynamic performance with an advanced combined power and refrigeration cycle with dual LNG cold energy utilization

被引:21
作者
Baigh, Tajwar A. [1 ]
Saif, Mostofa J. [1 ]
Mustakim, Ashraf [1 ]
Nanzeeba, Fairooz [1 ]
Khan, Yasin [1 ]
Ehsan, M. Monjurul [1 ]
机构
[1] Islamic Univ Technol IUT, Dept Mech & Prod Engn MPE, Board Bazar 1704, Gazipur, Bangladesh
关键词
Waste heat recovery; Multi-objective optimization; Exergy analysis; Cascade power cycle; Absorption refrigeration; Thermo-economic analysis; Nomenclature; LIQUEFIED NATURAL-GAS; EQUATION-OF-STATE; GRADE WASTE HEAT; RANKINE-CYCLE; SUPERCRITICAL CO2; EXERGY ANALYSIS; AMMONIA-WATER; FLUID REGION; ABSORPTION; SYSTEM;
D O I
10.1016/j.heliyon.2024.e35748
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Utilizing waste heat to drive thermodynamic systems is imperative for improving energy efficiency, thereby improving sustainability. A combined cooling and power systems (CCP) utilizes heat from a temperature source to deliver both power and cooling. However, CCP systems utilizing LNG cold energy suffers from low second law efficiency due to significant temperature differences. To address this, an "Advanced Power and Cooling with LNG Utilization (ACPLU)" system is proposed, integrating a cascaded transcritical carbon dioxide (TCO2)-LNG cycle with an Organic Rankine cycle (ORC) for improved power generation and an absorption refrigeration system (ARS) for simultaneous cooling. This study evaluates the second law efficiency, net work output, and exergy destruction performance through a sensitivity analysis, optimizing variables such as heat source temperature, superheater temperature difference, ORC and CO2 turbine inlet and condenser pressures, evaporator temperature, and pinch point temperatures of heat exchangers and generator. Compared to previous studies on CCP systems, the ACPLU shows a superior performance, with a second law efficiency of 27.3 % and a net work output of 11.76 MW. Cyclopentane as an ORC working fluid resulted in the highest second law efficiency of 29.06 % and net work output of 12.27 MW. Parametric analysis suggested that heat source temperature significantly impacts net power output. The exergy analysis concluded that a high-pressure ratio and good thermal match between the heat exchangers enhance overall performance. Utilizing artificial neural network (ANN) to produce a multiple-input-multiple-output (MIMO) objective function and performing multi-objective optimization (MOO) using genetic algorithm (GA), an improved second law efficiency and net power output by 28.11 % and 14.16 MW respectively, with pentane as the working fluid, is demonstrated. An average cost rate of 9.121 $/GJ was observed through a thermo-economic analysis. The ACPLU system is promising for medium temperature waste heat recovery, such as, pharmaceutical manufacturing plants.
引用
收藏
页数:37
相关论文
共 76 条
[31]   Ejector and Vapor Injection Enhanced Novel Compression-Absorption Cascade Refrigeration Systems: A Thermodynamic Parametric and Refrigerant Analysis [J].
Khan, Yasin ;
Faruque, Md Walid ;
Nabil, Mahdi Hafiz ;
Ehsan, M. Monjurul .
ENERGY CONVERSION AND MANAGEMENT, 2023, 289
[32]   Optimal working conditions of various city gate stations for power and hydrogen production based on energy and eco-exergy analysis [J].
Kowsari, Soheil ;
Deymi-Dashtebayaz, Mahdi ;
Karbasi, Kamyab ;
Sheikhani, Hamideh .
INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2020, 45 (43) :22513-22533
[33]   What are artificial neural networks? [J].
Krogh, Anders .
NATURE BIOTECHNOLOGY, 2008, 26 (02) :195-197
[34]  
kumar S.A., 2016, IOSR J. Mech. Civ. Eng., V13, P57, DOI [10.9790/1684-1304025762, DOI 10.9790/1684-1304025762]
[35]  
Lemmon E.W., 2007, NIST Standard reference database 23, Reference fluid thermodynamic and transport properties-REFPROP
[36]   Short fundamental equations of state for 20 industrial fluids [J].
Lemmon, Eric W. ;
Span, Roland .
JOURNAL OF CHEMICAL AND ENGINEERING DATA, 2006, 51 (03) :785-850
[37]   Preliminary conceptual design and thermodynamic comparative study on vapor absorption refrigeration cycles integrated with a supercritical CO2 power cycle [J].
Li, Hang ;
Su, Wei ;
Cao, Liyan ;
Chang, Feng ;
Xia, Wenkai ;
Dai, Yiping .
ENERGY CONVERSION AND MANAGEMENT, 2018, 161 :162-171
[38]   Thermodynamic analysis of a novel combined cooling and power system utilizing liquefied natural gas (LNG) cryogenic energy and low-temperature waste heat [J].
Li, Yongyi ;
Liu, Yujia ;
Zhang, Guoqiang ;
Yang, Yongping .
ENERGY, 2020, 199 (199)
[39]   Theoretical analysis of a regenerative supercritical carbon dioxide Brayton cycle/organic Rankine cycle dual loop for waste heat recovery of a diesel/natural gas dual-fuel engine [J].
Liang, Youcai ;
Bian, Xingyan ;
Qian, Weiwei ;
Pan, Mingzhang ;
Ban, Zhibo ;
Yu, Zhibin .
ENERGY CONVERSION AND MANAGEMENT, 2019, 197
[40]   A Transcritical CO2 Rankine Cycle With LNG Cold Energy Utilization and Liquefaction of CO2 in Gas Turbine Exhaust [J].
Lin, Wensheng ;
Huang, Meibin ;
He, Hongming ;
Gu, Anzhong .
JOURNAL OF ENERGY RESOURCES TECHNOLOGY-TRANSACTIONS OF THE ASME, 2009, 131 (04)