Online and offline Radiation-Induced Attenuation measurements on FD-7 radiophotoluminescence dosimeters irradiated at high X-ray doses

被引:1
作者
Hasan, A. [1 ,4 ]
Aguiar, Y. [1 ,2 ]
Alia, R. Garcia [2 ]
Campanella, C. [1 ,5 ]
Morana, A. [1 ]
Alem, A. K. [1 ]
Girard, S. [1 ,3 ]
Mandal, A. Raj [1 ]
Ferrari, M. [1 ]
机构
[1] Univ Jean Monnet St Etienne, CNRS, Lab Hubert Curien, UMR 5516, F-42023 St Etienne, France
[2] European Org Nucl Res CERN, CH-1211 Geneva, Switzerland
[3] Minist Enseignement Super & Rech, Inst Univ France IUF, F-75005 Paris, France
[4] nanoCaps AS, Vestfold Innovat Pk,Raveien 205, N-3184 Borre, Norway
[5] EXAIL PHOTON, 3 Rue Sophie Germain, F-25000 Besancon, France
关键词
Dosimetry; Radiophotoluminescence (RPL); Radiation-Induced Attenuation (RIA); X-ray; Transmittance; PHOTON DOSIMETRY; SILVER;
D O I
10.1016/j.radmeas.2024.107246
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Radiophotoluminescence (RPL) FD-7 glass dosimeters find applications in low to high dose radiation environments. This work presents an experimental characterization of RPL glass dosimeter, irradiated with 100 kV X-ray tubes at room temperature at doses ranging from 1.3 kGy to 0.47 MGy, much higher of their common use range. In this study, a customized set-up has been developed, allowing the online investigation of the glass transmission changes with radiation, known as Radiation-Induced Attenuation (RIA), as well as the recovery and post-mortem characterizations up to 2 months after irradiation. Multi-wavelength analysis was performed, focusing on the range between 200 nm and 800 nm. At 700 nm and 800 nm, RIA increases progressively with dose up to about 5 kGy, and tends to approach saturation (2-3 dB/mm) for doses higher than 50 kGy. Higher attenuation is reported at lower wavelengths: 445-nm light transmission reduces to only about 1% of its initial value after 2 kGy. RIA recovery after irradiation was observed, up to 6% at 700 nm wavelength within 3 h from the irradiation conclusion and up to 26% 2 months after, especially at doses in the kGy range. Both online RIA and its recovery are highly dependent on the selected wavelength and on the total absorbed dose. This information is crucial for the extension of the use of these dosimeters up to high doses, complementary to the RPL signal, traditionally used alone for the determination of doses up to the Gy range.
引用
收藏
页数:9
相关论文
共 39 条
  • [11] Overview of radiation induced point defects in silica-based optical fibers
    Girard S.
    Alessi A.
    Richard N.
    Martin-Samos L.
    De Michele V.
    Giacomazzi L.
    Agnello S.
    Francesca D.D.
    Morana A.
    Winkler B.
    Reghioua I.
    Paillet P.
    Cannas M.
    Robin T.
    Boukenter A.
    Ouerdane Y.
    [J]. Reviews in Physics, 2019, 4
  • [12] Radiation Effects on Silica-Based Optical Fibers: Recent Advances and Future Challenges
    Girard, S.
    Kuhnhenn, J.
    Gusarov, A.
    Brichard, B.
    Van Uffelen, M.
    Ouerdane, Y.
    Boukenter, A.
    Marcandella, C.
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2013, 60 (03) : 2015 - 2036
  • [13] Growth and Decay Kinetics of Radiation-Induced Attenuation in Bulk Optical Materials
    Girard, Sylvain
    Allanche, Timothe
    Paillet, Philippe
    Goiffon, Vincent
    Van Uffelen, Marco
    Mont-Casellas, Laura
    Muller, Cyprien
    Boukenter, Aziz
    Ouerdane, Youcef
    De Cock, Wouter
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2018, 65 (08) : 1612 - 1618
  • [14] Recent advances in radiation-hardened fiber-based technologies for space applications
    Girard, Sylvain
    Morana, Adriana
    Ladaci, Ayoub
    Robin, Thierry
    Mescia, Luciano
    Bonnefois, Jean-Jacques
    Boutillier, Mathieu
    Mekki, Julien
    Paveau, Armelle
    Cadier, Benoit
    Marin, Emmanuel
    Ouerdane, Youcef
    Boukenter, Aziz
    [J]. JOURNAL OF OPTICS, 2018, 20 (09)
  • [15] Femtosecond Direct Laser Writing of Silver Clusters in Phosphate Glasses for X-ray Spatially-Resolved Dosimetry
    Harb, Joelle
    Guerineau, Theo
    Morana, Adriana
    Meyer, Arnaud
    Raffy, Guillaume
    Del Guerzo, Andre
    Ouerdane, Youcef
    Boukenter, Aziz
    Girard, Sylvain
    Cardinal, Thierry
    Petit, Yannick
    Canioni, Lionel
    [J]. CHEMOSENSORS, 2022, 10 (03)
  • [16] Beam Loss Monitoring for LHC Machine Protection
    Holzer, Eva Barbara
    Dehning, Bernd
    Effinger, Ewald
    Emery, Jonathan
    Grishin, Viatcheslav
    Hajdu, Csaba
    Jackson, Stephen
    Kurfuerst, Christoph
    Marsili, Aurelien
    Misiowiec, Marek
    Nagel, Markus
    Del Busto, Eduardo Nebot
    Nordt, Annika
    Roderick, Chris
    Sapinski, Mariusz
    Zamantzas, Christos
    [J]. PROCEEDINGS OF THE 2ND INTERNATIONAL CONFERENCE ON TECHNOLOGY AND INSTRUMENTATION IN PARTICLE PHYSICS (TIPP 2011), 2012, 37 : 2055 - 2062
  • [17] Huang D.Y.C., 2011, Advances in Cancer Therapy, DOI [10.5772/23710, DOI 10.5772/23710]
  • [18] Characterisation of RPL and TL dosimetry systems and comparison in medical dosimetry applications
    Knezevic, Z.
    Beck, N.
    Milkovic, D.
    Miljanic, S.
    Ranogajec-Komor, M.
    [J]. RADIATION MEASUREMENTS, 2011, 46 (12) : 1582 - 1585
  • [19] Photon dosimetry methods outside the target volume in radiation therapy: Optically stimulated luminescence (OSL), thermoluminescence (TL) and radiophotoluminescence (RPL) dosimetry
    Knezevic, Zeljka
    Stolarczyk, Liliana
    Bessieres, Igor
    Bordy, Jean Marc
    Miljanic, Saveta
    Olko, Pawel
    [J]. RADIATION MEASUREMENTS, 2013, 57 : 9 - 18
  • [20] Performance characterisation of a real-time fiber dosimetry system using radiophotoluminescent glasses
    Kurobori, Toshio
    [J]. JAPANESE JOURNAL OF APPLIED PHYSICS, 2018, 57 (10)