Robust localization of poorly visible tumor in fiducial free stereotactic body radiation therapy

被引:1
作者
Xu, Di [1 ]
Descovich, Martina [1 ]
Liu, Hengjie [2 ]
Sheng, Ke [1 ]
机构
[1] Univ Calif San Francisco, Radiat Oncol, San Francisco, CA USA
[2] Univ Calif Los Angeles, Radiat Oncol, Los Angeles, CA USA
关键词
Deep learning; Pulmonary cancer; SBRT; Fiducial-free tracking; Object detection; CELL LUNG-CANCER; VOLUME HISTOGRAM ANALYSIS; COMPUTED-TOMOGRAPHY; RADIOTHERAPY; PNEUMONITIS; COMPLICATIONS; RADIOSURGERY; PLACEMENT; MARKERS; MOTION;
D O I
10.1016/j.radonc.2024.110514
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background and purpose: Effective respiratory motion management reduces healthy tissue toxicity and ensures sufficient dose delivery to lung cancer cells in pulmonary stereotactic body radiation therapy (SBRT) with high fractional doses. An articulated robotic arm paired with an X-ray imaging system is designed for real-time motion-tracking (RTMT) dose delivery. However, small tumors (<15 mm) or tumors at challenging locations may not be visible in the X-ray images, disqualifying patients with such tumors from RTMT dose delivery unless fiducials are implanted via an invasive procedure. To track these practically invisible lung tumors in SBRT, we hereby develop a deep learning-enabled template-free tracking framework, SAFE Track. Methods: SAFE Track is a fully supervised framework that trains a generalizable prior for template-free target localization. Two sub-stages are incorporated in SAFE Track, including the initial pretraining on two large-scale medical image datasets (DeepLesion and Node21) followed by fine-tuning on our in-house dataset. A two-stage detector, Faster R-CNN, with a backbone of ResNet50, was selected as our detection network. 94 patients (415 fractions; 40,348 total frames) with low tumor visibility who thus had implanted fiducials were included. The cohort is categorized by the longest dimension of the tumor (<10 mm, 10-15 mm and > 15 mm). The patients were split into training (n = 66) and testing (n = 28) sets. We simulated fiducial-free tumors by removing the fiducials from the X-ray images. We classified the patients into two groups - fiducial implanted inside tumors and implanted outside tumors. To ensure the rigor of our experiment design, we only conducted fiducial removal simulation in training patients and utilized patients with fiducial implanted outside of the tumors for testing. Commercial Xsight Lung Tracking (XLT) and a Deep Match were included for comparison. Results: SAFE Track achieves promising outcomes to as accurate as 1.23 +/- 1.32 mm 3D distance in testing patients with tumor size > 15 mm where Deep Match is at 4.75 +/- 1.67 mm and XLT is at 12.23 +/- 4.58 mm 3D distance. Even for the most challenging tumor size (<10 mm), SAFE Track maintains its robustness at 1.82 plus or minus 1.67 mm 3D distance, where Deep Match is at 5.32 plus or minus 2.32 mm, and XLT is at 24.83 +/- 12.95 mm 3D distance. Moreover, SAFE Track can detect some considerably challenging cases where the tumor is almost invisible or overlapped with dense anatomies. Conclusion: SAFE Track is a robust, clinically compatible, fiducial-free, and template-free tracking framework that is applicable to patients with small tumors or tumors obscured by overlapped anatomies in SBRT.
引用
收藏
页数:8
相关论文
共 46 条
  • [1] Predictive Parameters of CyberKnife Fiducial-less (XSight Lung) Applicability for Treatment of Early Non-Small Cell Lung Cancer: A Single-Center Experience
    Bahig, Houda
    Campeau, Marie-Pierre
    Vu, Toni
    Doucet, Robert
    Nadeau, Dominic Beliveau
    Fortin, Bernard
    Roberge, David
    Lambert, Louise
    Carrier, Jean-Francois
    Filion, Edith
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 87 (03): : 583 - 589
  • [2] Complications Associated with the Percutaneous Insertion of Fiducial Markers in the Thorax
    Bhagat, Nikhil
    Fidelman, Nicholas
    Durack, Jeremy C.
    Collins, Jeremy
    Gordon, Roy L.
    LaBerge, Jeanne M.
    Kerlan, Robert K., Jr.
    [J]. CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2010, 33 (06) : 1186 - 1191
  • [3] Deng J, 2009, PROC CVPR IEEE, P248, DOI 10.1109/CVPRW.2009.5206848
  • [4] Di Xu, 2023, Arxiv, DOI arXiv:2302.09696
  • [5] Free breathing gated detivery (FBGD) of lung radiation therapy: Analysis of factors affecting clinical patient throughput
    Fox, Timothy
    Simon, Edmund L.
    Elder, Eric
    Riffenburgh, Robert H.
    Johnstone, Peter A. S.
    [J]. LUNG CANCER, 2007, 56 (01) : 69 - 75
  • [6] Fu D., 2007, Treting Tumors that move with Respiration, P265, DOI DOI 10.1007/978-3-540-69886-926
  • [7] Clinical dose-volume histogram analysis for pneumonitis after 3D treatment for non-small cell lung cancer (NSCLC)
    Graham, MV
    Purdy, JA
    Emami, B
    Harms, W
    Bosch, W
    Lockett, MA
    Perez, CA
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1999, 45 (02): : 323 - 329
  • [8] He KM, 2018, Arxiv, DOI arXiv:1703.06870
  • [9] He KM, 2015, Arxiv, DOI [arXiv:1512.03385, DOI 10.48550/ARXIV.1512.03385]
  • [10] Radiation-induced pulmonary toxicity: A dose-volume histogram analysis in 201 patients with lung cancer
    Hernando, ML
    Marks, LB
    Bentel, GC
    Zhou, SM
    Hollis, D
    Das, SK
    Fan, M
    Munley, MT
    Shafman, TD
    Anscher, MS
    Lind, PA
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2001, 51 (03): : 650 - 659