Accelerated cardiac cine magnetic resonance imaging using deep low-rank plus sparse network: validation in patients

被引:0
作者
Yan, Chenyuan [1 ]
Liu, Yuanyuan [1 ]
Wang, Che [1 ]
Fan, Weixiong [2 ]
Zhu, Yanjie [1 ]
机构
[1] Chinese Acad Sci, Shenzhen Inst Adv Technol, Paul C Lauterbur Res Ctr Biomed Imaging, 1068 Xueyuan Ave, Shenzhen 518055, Peoples R China
[2] Meizhou Peoples Hosp, Dept Magnet Resonance, Guangdong Prov Key Lab Precis Med & Clin Translat, 63 Huangtang Rd, Meizhou 514031, Peoples R China
基金
中国国家自然科学基金;
关键词
Magnetic resonance imaging (MRI); cine; deep learning (DL); cardiac function; K-T BLAST; DYNAMIC MRI; RECONSTRUCTION; SENSE; GRAPPA;
D O I
10.21037/qims-24-17
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Accurate and reproducible assessment of left ventricular (LV) volumes is important in managing various cardiac conditions. However, patients are required to hold their breath multiple times during data acquisition, which may result in discomfort and restrict cardiac motion, potentially compromising the accuracy of the detected results. Accelerated imaging techniques can help reduce the number of breath holds needed, potentially improving patient comfort and the reliability of the LV assessment. This study aimed to prospectively evaluate the feasibility and accuracy of LV assessment with a model-based low-rank plus sparse network (L+S-Net) for accelerated magnetic resonance (MR) cine imaging. Methods: Fourty-one patients with different cardiac conditions were recruited in this study. Both accelerated MR cine imaging with L+S-Net and traditional electrocardiogram (ECG)-gated segmented cine were performed for each patient. Subjective image quality (IQ) score and quantitative LV volume function parameters were measured and compared between L+S-Net and traditional standards. The IQ score and LV volume measurements of cardiovascular magnetic resonance (CMR) images reconstructed by L+S-Net and standard cine were compared by paired t-test. The acquisition time of the two methods was also calculated. Results: In a quantitative analysis, L+S-Net and standard cine yielded similar measurements for all parameters of LV function (ejection fraction: 35 +/- 22 for standard vs . 33 +/- 23 for L+S-Net), although L+S-Net had slightly lower IQ scores than standard cine CMR (4.2 +/- 0.5 for L+S-Net vs . 4.8 +/- 0.4 for standard cine; P<0.001). The mean acquisition time of L+S-Net and standard cine was 0.83 +/- 0.08 vs . 6.35 +/- 0.78 s per slice (P<0.001). Conclusions: Assessment of LV function with L+S-Net at 3.0 T yields comparable results to the reference standard, albeit with a reduced acquisition time. This feature enhances the clinical applicability of the L+SNet approach, helping alleviate patient discomfort and motion artifacts that may arise due to prolonged acquisition time.
引用
收藏
页码:5131 / 5143
页数:13
相关论文
共 62 条
  • [41] Accelerating cardiac cine MRI using a deep learning-based ESPIRiT reconstruction
    Sandino, Christopher M.
    Lai, Peng
    Vasanawala, Shreyas S.
    Cheng, Joseph Y.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2021, 85 (01) : 166 - 181
  • [42] A Deep Cascade of Convolutional Neural Networks for Dynamic MR Image Reconstruction
    Schlemper, Jo
    Caballero, Jose
    Hajnal, Joseph V.
    Price, Anthony N.
    Rueckert, Daniel
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2018, 37 (02) : 491 - 503
  • [43] Improved Radial GRAPPA Calibration for Real-Time Free-Breathing Cardiac Imaging
    Seiberlich, Nicole
    Ehses, Philipp
    Duerk, Jeff
    Gilkeson, Robert
    Griswold, Mark
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2011, 65 (02) : 492 - 505
  • [44] Supranormal Left Ventricular Ejection Fraction, Stroke Volume, and Cardiovascular Risk p Findings From Population-Based Cohort Studies
    Shah, Sonia
    Segar, Matthew W.
    Kondamudi, Nitin
    Ayers, Colby
    Chandra, Alvin
    Matulevicius, Susan
    Agusala, Kartik
    Peshock, Ron
    Abbara, Suhny
    Michos, Erin D.
    Drazner, Mark H.
    Lima, Joao A. C.
    Longstreth Jr, W. T.
    Pandey, Ambarish
    [J]. JACC-HEART FAILURE, 2022, 10 (08) : 583 - 594
  • [45] Calibrationless Parallel Imaging Reconstruction Based on Structured Low-Rank Matrix Completion
    Shin, Peter J.
    Larson, Peder E. Z.
    Ohliger, Michael A.
    Elad, Michael
    Pauly, John M.
    Vigneron, Daniel B.
    Lustig, Michael
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2014, 72 (04) : 959 - 970
  • [46] MR Image Reconstruction Using Deep Density Priors
    Tezcan, Kerem C.
    Baumgartner, Christian F.
    Luechinger, Roger
    Pruessmann, Klaas P.
    Konukoglu, Ender
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2019, 38 (07) : 1633 - 1642
  • [47] Compressed Sensing MRI Reconstruction Using a Generative Adversarial Network With a Cyclic Loss
    Tran Minh Quan
    Thanh Nguyen-Duc
    Jeong, Won-Ki
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2018, 37 (06) : 1488 - 1497
  • [48] Optimizing spatiotemporal sampling for k-t BLAST and k-t SENSE:: Application to high-resolution real-time cardiac steady-state free precession
    Tsao, J
    Kozerke, S
    Boesiger, P
    Pruessmann, KP
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2005, 53 (06) : 1372 - 1382
  • [49] k-t BLAST and k-t SENSE:: Dynamic MRI with high frame rate exploiting spatiotemporal correlations
    Tsao, J
    Boesiger, P
    Pruessmann, KP
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2003, 50 (05) : 1031 - 1042
  • [50] ESPIRiT-An Eigenvalue Approach to Autocalibrating Parallel MRI: Where SENSE Meets GRAPPA
    Uecker, Martin
    Lai, Peng
    Murphy, Mark J.
    Virtue, Patrick
    Elad, Michael
    Pauly, John M.
    Vasanawala, Shreyas S.
    Lustig, Michael
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2014, 71 (03) : 990 - 1001