Design of poly(vinyl pyrrolidone) and poly(ethylene glycol) microneedle arrays for delivering glycosaminoglycan, chondroitin sulfate, and hyaluronic acid

被引:0
作者
Choupani, Andisheh [1 ]
Temucin, Elif Sevval [1 ]
Ciftci, Eda [1 ]
Bakan, Feray [2 ]
Camic, Busra Tugba [2 ]
Ozkoc, Guralp [2 ,3 ]
Sezen, Meltem [2 ]
Korkusuz, Petek [4 ,5 ]
Korkusuz, Feza [6 ]
Bediz, Bekir [1 ,7 ]
机构
[1] Sabanci Univ, Fac Engn & Nat Sci, Mechatron Engn Program, Istanbul, Turkiye
[2] Sabanci Univ, SUNUM Nanotechnol Res & Applicat Ctr, Istanbul, Turkiye
[3] Istinye Univ, Dept Chem, Istanbul, Turkiye
[4] Hacettepe Univ, Fac Med, Dept Histol & Embryol, Ankara, Turkiye
[5] METU MEMS Ctr, Ankara, Turkiye
[6] Hacettepe Univ, Fac Med, Dept Sports Med, Ankara, Turkiye
[7] Sabanci Univ, Integrated Mfg Technol Res & Applicat Ctr, Istanbul, Turkiye
关键词
Microneedle; microneedle array; needle geometry optimization; glycosaminoglycan; chondroitin sulfate; hyaluronic acid; LOADED DISSOLVING MICRONEEDLES; IN-VITRO; POLYMER MICRONEEDLES; SKIN; OSTEOARTHRITIS; FABRICATION; PENETRATION; MECHANICS; ALGORITHM; EFFICIENT;
D O I
10.1080/09205063.2024.2392914
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Osteoarthritis (OA) is a prevalent joint disorder characterized by cartilage and bone degradation. Medical therapies like glucosaminoglycan (GAG), chondroitin sulfate (CS), and hyaluronic acid (HA) aim to preserve joint function and reduce inflammation but may cause side effects when administered orally or via injection. Microneedle arrays (MNAs) offer a localized drug delivery method that reduces side effects. Thus, this study aims to demonstrate the feasibility of delivering GAG, CS, and HA using microneedles in vitro. An optimal needle geometry is crucial for the successful application of MNA. To address this, here we employ a multi-objective optimization framework using the non-dominated sorting genetic algorithm II (NSGA-II) to determine the ideal MNA design, focusing on preventing needle failure. Then, a three-step fabrication approach is followed to fabricate the MNAs. First, the master (male) molds are fabricated from poly(methyl methacrylate) using mechanical micromachining based on optimized needle geometry. Second, a micro-molding with Polydimethylsiloxane (PDMS) is used for the fabrication of production (female) molds. In the last step, the MNAs were fabricated by microcasting the hydrogels using the production molds. Light microscopy (LIMI) confirms the accuracy of the MNAs manufactured, and in vitro skin insertion tests demonstrate failure-free needle insertion. Subsequently, we confirmed the biocompatibility of MNAs by evaluating their impact on the L929 fibroblast cell line, human chondrocytes, and osteoblasts.