Validity of Endometrial Cavity Length on 3D Pelvic Ultrasound before Endometrial Ablation

被引:0
|
作者
Shine, Kayla [1 ]
Cowherd, Rachael [2 ]
Rowin, Alexandra [2 ]
Soora, Raksha [2 ]
Meglin, Michelle [2 ]
机构
[1] Med Univ South Carolina, Coll Med, Charleston, SC USA
[2] Med Univ South Carolina, Dept Obstet & Gynecol, Charleston, SC USA
关键词
endometrial ablation; endometrial cavity length; midcoronal plane; UTERINE; MULTICENTER; UTERUS; WOMEN; 2D;
D O I
10.14423/SMJ.0000000000001736
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives: This study aimed to compare endometrial cavity length measurements obtained by preoperative three-dimensional (3D) reconstruction of coronal images on pelvic ultrasound with intraoperative endometrial cavity measurements obtained in advance of Minerva endometrial ablation. Methods: This was a retrospective cohort study of 41 individuals who underwent a Minerva endometrial ablation between August 1, 2018 and March 15, 2022 at a single academic medical center. Patients were excluded if they had an in-clinic ablation or no ultrasound with 3D uterine volume within 180 days before surgery. Physician sonologists measured the endometrial cavity length using 3D coronal reconstruction of the cavity. Two measurements were obtained by separate physicians who were blinded to intraoperative values. Intraoperative endometrial cavity lengths were obtained from operative reports. A Bland-Altman plot was used to evaluate the agreement of intraoperative and ultrasound measurements. Results: The mean intraoperative endometrial cavity length (50.7 +/- 7.8 mm) was greater than the mean endometrial cavity length by 3D coronal reconstruction of pelvic ultrasound (36.1 +/- 6.2 mm, P < 0.0001). The average difference between intraoperative and ultrasound measurements of cavity length was 14.6 +/- 9.0 mm. The agreement between measurements was poor (Lin's concordance correlation coefficient 0.06). Using a Bland-Altman plot, the limits of agreement (-3.1 to 32 mm) exceeded the a priori acceptable limits of agreement (-10 to 10 mm). Conclusions: Our findings suggest that preoperative coronal endometrial cavity length measurements by ultrasound are not a valid substitute for intraoperative measurements before Minerva ablation.
引用
收藏
页码:599 / 602
页数:4
相关论文
共 50 条
  • [41] Goserelin acetate (Zoladex) plus endometrial ablation for dysfunctional uterine bleeding: a 3-year follow-up evaluation
    Donnez, J
    Vilos, G
    Gannon, MJ
    Maheux, R
    Emanuel, MH
    Istre, O
    FERTILITY AND STERILITY, 2001, 75 (03) : 620 - 622
  • [42] Utility of three dimensional (3-D) ultrasound and power Doppler in identification of high risk endometrial cancer at a tertiary care hospital in southern India: A preliminary study
    Pandey, Harshitha
    Guruvare, Shyamala
    Kadavigere, Rajagopal
    Rao, Chythra R.
    TAIWANESE JOURNAL OF OBSTETRICS & GYNECOLOGY, 2018, 57 (04): : 522 - 527
  • [43] Does vaginal delivery cause more damage to the pelvic floor than cesarean section as determined by 3D ultrasound evaluation? A systematic review
    de Araujo, Camila Carvalho
    Coelho, Suelene A.
    Stahlschmidt, Paulo
    Juliato, Cassia R. T.
    INTERNATIONAL UROGYNECOLOGY JOURNAL, 2018, 29 (05) : 639 - 645
  • [44] Combined 3D Endoanal Ultrasound and Transperineal Ultrasound Improves the Detection of Anal Sphincter Defects
    Carter, Dan
    Ram, Edward
    Engel, Tal
    DIAGNOSTICS, 2023, 13 (04)
  • [45] Pelvic floor muscle dysfunction at 3D transperineal ultrasound in maternal exposure to gestational diabetes mellitus: A prospective cohort study during pregnancy
    Pinheiro, Fabiane A.
    Sartorao Filho, Carlos I.
    Prudencio, Caroline B.
    Nunes, Sthefanie K.
    Pascon, Tawana
    Hallur, Ragavendra L. S.
    Takano, Luis
    Enriquez, Eusebio M. A.
    Catinelli, Bruna B.
    Carr, Aline M.
    Junginger, Baerbel
    Rudge, Marilza V. C.
    Barbosa, Angelica M. P.
    NEUROUROLOGY AND URODYNAMICS, 2022, 41 (05) : 1127 - 1138
  • [46] Clinical Significance of 3D Ultrasound Compared to MRI in Uterine Malformations
    Imboden, S.
    Mueller, M.
    Raio, L.
    Mueller, M. D.
    Tutschek, B.
    ULTRASCHALL IN DER MEDIZIN, 2014, 35 (05): : 440 - 444
  • [47] Transanal (3D) ultrasound diagnostics of sphincter defects and rectovaginal fistulas
    Loehnert, Mathias
    COLOPROCTOLOGY, 2020, 42 (03) : 246 - 253
  • [48] Automated 3D ultrasound elastography of the breast: a phantom validation study
    Hendriks, Gijs A. G. M.
    Hollander, Branislav
    Menssen, Jan
    Milkowski, Andy
    Hansen, Hendrik H. G.
    de Korte, Chris L.
    PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (07) : 2665 - 2679
  • [49] Three-dimensional complementary breast ultrasound (3D CBUS): Improving 3D spatial resolution uniformity with orthogonal images
    Park, Claire Keun Sun
    Aziz, Amal
    Trumpour, Tiana
    Bax, Jeffrey Scott
    Tessier, David
    Gyacskov, Igor
    Gardi, Lori
    Fenster, Aaron
    MEDICAL PHYSICS, 2025, : 2438 - 2453
  • [50] The importance of using 3D ultrasound during pelvic organ prolapse surgery in relation to pre- and post-operative quality of life questionnaires
    David, M.
    Catala, L.
    Lefebvre, C.
    Descamp, Ph.
    Legendre, G.
    JOURNAL OF GYNECOLOGY OBSTETRICS AND HUMAN REPRODUCTION, 2020, 49 (06)