Validity of Endometrial Cavity Length on 3D Pelvic Ultrasound before Endometrial Ablation

被引:0
|
作者
Shine, Kayla [1 ]
Cowherd, Rachael [2 ]
Rowin, Alexandra [2 ]
Soora, Raksha [2 ]
Meglin, Michelle [2 ]
机构
[1] Med Univ South Carolina, Coll Med, Charleston, SC USA
[2] Med Univ South Carolina, Dept Obstet & Gynecol, Charleston, SC USA
关键词
endometrial ablation; endometrial cavity length; midcoronal plane; UTERINE; MULTICENTER; UTERUS; WOMEN; 2D;
D O I
10.14423/SMJ.0000000000001736
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives: This study aimed to compare endometrial cavity length measurements obtained by preoperative three-dimensional (3D) reconstruction of coronal images on pelvic ultrasound with intraoperative endometrial cavity measurements obtained in advance of Minerva endometrial ablation. Methods: This was a retrospective cohort study of 41 individuals who underwent a Minerva endometrial ablation between August 1, 2018 and March 15, 2022 at a single academic medical center. Patients were excluded if they had an in-clinic ablation or no ultrasound with 3D uterine volume within 180 days before surgery. Physician sonologists measured the endometrial cavity length using 3D coronal reconstruction of the cavity. Two measurements were obtained by separate physicians who were blinded to intraoperative values. Intraoperative endometrial cavity lengths were obtained from operative reports. A Bland-Altman plot was used to evaluate the agreement of intraoperative and ultrasound measurements. Results: The mean intraoperative endometrial cavity length (50.7 +/- 7.8 mm) was greater than the mean endometrial cavity length by 3D coronal reconstruction of pelvic ultrasound (36.1 +/- 6.2 mm, P < 0.0001). The average difference between intraoperative and ultrasound measurements of cavity length was 14.6 +/- 9.0 mm. The agreement between measurements was poor (Lin's concordance correlation coefficient 0.06). Using a Bland-Altman plot, the limits of agreement (-3.1 to 32 mm) exceeded the a priori acceptable limits of agreement (-10 to 10 mm). Conclusions: Our findings suggest that preoperative coronal endometrial cavity length measurements by ultrasound are not a valid substitute for intraoperative measurements before Minerva ablation.
引用
收藏
页码:599 / 602
页数:4
相关论文
共 50 条
  • [1] Ultrasound Evaluation of the Postpartum Endometrial Cavity
    Fuller, Kisti P.
    Feldman, Deborah M.
    JOURNAL OF REPRODUCTIVE MEDICINE, 2015, 60 (1-2) : 3 - 5
  • [2] Evaluation of the NovaSure Endometrial Ablation Procedure in Women With Uterine Cavity Length Over 10 cm
    Thiel, John A.
    Briggs, M. Martha
    Pohlman, Scott
    Rattray, Darrien
    JOURNAL OF OBSTETRICS AND GYNAECOLOGY CANADA, 2014, 36 (06) : 491 - 497
  • [3] The use of transvaginal ultrasound evaluation premicrowave endometrial ablation
    Shuen, W. M. Vivien
    Vardhanabhuti, Varut V.
    Pearson, Sally A.
    ULTRASOUND, 2011, 19 (01) : 36 - 38
  • [4] 3D ultrasound assessment of endometrial junctional zone anatomy as a predictor of the outcome of ICSI cycles
    Maged, Ahmed M.
    Ramzy, Abdel-Maguid
    Ghar, Mona Aboul
    El Shenoufy, Hossam
    Allah, Sherine H. Gad
    Wahba, Amr H.
    ElKateb, AbdAllah Y.
    Hwedi, Noha
    EUROPEAN JOURNAL OF OBSTETRICS & GYNECOLOGY AND REPRODUCTIVE BIOLOGY, 2017, 212 : 160 - 165
  • [5] Ultrasound examination before, during, and after office endometrial sampling
    Van den Bosch, Thierry
    Van Schoubroeck, Dominique
    Timmerman, Dirk
    GYNECOLOGICAL SURGERY, 2014, 11 (02) : 83 - 88
  • [6] New-onset pelvic organ prolapse after Novasure endometrial ablation
    Tunitsky, Elena
    Dardano, Kristin
    Harmanli, Oezguer H.
    ARCHIVES OF GYNECOLOGY AND OBSTETRICS, 2008, 278 (02) : 187 - 189
  • [7] New-onset pelvic organ prolapse after Novasure endometrial ablation
    Elena Tunitsky
    Kristin Dardano
    Özgür H. Harmanli
    Archives of Gynecology and Obstetrics, 2008, 278 : 187 - 189
  • [8] Uterine Ultrasound Findings After Radiofrequency Endometrial Ablation Correlation With Symptoms
    AlHilli, Mariam M.
    Wall, Darci J.
    Brown, Douglas L.
    Weaver, Amy L.
    Hopkins, Matthew R.
    Famuyide, Abimbola O.
    ULTRASOUND QUARTERLY, 2012, 28 (04) : 261 - 268
  • [9] An investigation of endometrial vascularity in normally menstruating women and those in other physiological states using 3D ultrasound imaging
    Khan, Ammar Ahmed
    Al-Motawa, Aisha
    Halabi, Najeeb
    Ahmed, Badreldeen
    Rafii, Jeremie Arash
    Konje, Justin C.
    INTERNATIONAL JOURNAL OF GYNECOLOGY & OBSTETRICS, 2024, 165 (03) : 1172 - 1181
  • [10] The diagnostic accuracy of 3D ultrasound compared to 2D ultrasound and MRI in the assessment of deep myometrial invasion in endometrial cancer patients: A systematic review
    Ziogas, Apostolos
    Xydias, Emmanouil
    Kalantzi, Sofi
    Papageorgouli, Despoina
    Liasidi, Polyxeni-Natalia
    Lamari, Ioanna
    Daponte, Alexandros
    TAIWANESE JOURNAL OF OBSTETRICS & GYNECOLOGY, 2022, 61 (05): : 746 - 754