Utility of Contrast-Enhanced Ultrasound in Optimizing Hepatic Abscess Treatment and Monitoring

被引:0
|
作者
Dobek, Adam [1 ]
Kobierecki, Mateusz [2 ]
Kosztowny, Konrad [3 ]
Grzasiak, Oliwia [3 ]
Fabisiak, Adam [4 ]
Falenta, Krzysztof [1 ]
Stefanczyk, Ludomir [1 ]
机构
[1] Med Univ Lodz, Norbert Barlicki Mem Teaching Hosp 1, Dept Radiol & Diag Imaging, PL-90153 Lodz, Poland
[2] Polish Mothers Mem Hosp Res Institite, Dept Diag Imaging, PL-90153 Lodz, Poland
[3] Med Univ Lodz, Norbert Barlicki Mem Teaching Hosp 1, Dept Gen Surg & Transplantol, PL-90153 Lodz, Poland
[4] Med Univ Lodz, Norbert Barlicki Mem Teaching Hosp 1, Dept Digest Tract Dis, PL-90153 Lodz, Poland
关键词
abscess; contrast-enhanced ultrasound; liver; percutaneous drainage; ultrasound; LIVER-ABSCESS; DRAINAGE; MANAGEMENT; CEUS;
D O I
10.3390/jcm13175046
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background/Objectives: Untreated hepatic abscesses (HAs) have an 80% mortality rate and can be caused by bacteria and fungi. Previously managed with surgery, current treatments now utilize interventional radiology and antibiotics, reducing complications to 2.5%. This study evaluates contrast-enhanced ultrasound (CEUS) for better drainage placement and monitoring, overcoming conventional ultrasound's limitations in detecting the HA liquefied portion. Methods: We conducted a retrospective study of 50 patients with HAs confirmed via computed tomography (CT) scans. Inclusion criteria comprised specific clinical symptoms and laboratory parameters. Both B-mode and CEUS were utilized for initial and follow-up imaging. Results: In the CEUS studies, the mean size of HAs was 6.26 cm, with pus displaying significantly lower echogenicity compared to the HA pouch and liver parenchyma in all phases. Classification by size (>6 cm, <6 cm) and volume (>113 mL, <113 mL) revealed differences in the assessment of fluid volume between CEUS and B-mode. Conclusions: CEUS is valuable for diagnosing, performing therapeutic procedures, and monitoring HA. It provides precise real-time assessment of HA morphology, including dimensions and volume. If the liquefied volume of an HA exceeds 113 mL, it may qualify for drainage placement. CEUS can replace CT as an effective, less harmful, and cheaper method, eliminating the need for multiple radiological departments. While CEUS is a safer, cost-effective alternative to CT for HA evaluation and monitoring, comprehensive clinical evaluation remains essential. Therefore, CEUS should be part of a broader diagnostic and monitoring strategy, not a stand-alone solution.
引用
收藏
页数:12
相关论文
共 50 条
  • [41] Contrast-enhanced ultrasound to assess gallbladder polyps
    Zhu, Lianhua
    Han, Peng
    Lee, Regis
    Jiang, Bo
    Jiao, Ziyu
    Li, Nan
    Tang, Wenbo
    Fei, Xiang
    CLINICAL IMAGING, 2021, 78 : 8 - 13
  • [42] Contrast-enhanced ultrasound in pediatric interventional radiology
    Acord, Michael R.
    Cahill, Anne Marie
    Durand, Rachelle
    Huang, Dean Y.
    Shellikeri, Sphoorti
    Vatsky, Seth
    Srinivasan, Abhay
    PEDIATRIC RADIOLOGY, 2021, 51 (12) : 2396 - 2407
  • [43] Contrast-enhanced ultrasound in the staging of acute pancreatitis
    Ripolles, Tomas
    Martinez, Maria J.
    Lopez, Estela
    Castello, Inmaculada
    Delgado, Fructuoso
    EUROPEAN RADIOLOGY, 2010, 20 (10) : 2518 - 2523
  • [44] Artifacts in contrast-enhanced ultrasound: a pictorial essay
    Fetzer, David T.
    Rafailidis, Vasileios
    Peterson, Cynthia
    Grant, Edward G.
    Sidhu, Paul
    Barr, Richard G.
    ABDOMINAL RADIOLOGY, 2018, 43 (04) : 977 - 997
  • [45] Contrast-enhanced ultrasound in the diagnosis of hepatocellular carcinoma
    Palmieri, Vincenzo O.
    Santovito, Daniela
    Marano, Giuseppe
    Minerva, Francesco
    Ricci, Lara
    D'Alitto, Felicia
    Angelelli, Giuseppe
    Palasciano, Giuseppe
    RADIOLOGIA MEDICA, 2015, 120 (07): : 627 - 633
  • [46] Contrast-Enhanced Ultrasound of Fibrolamellar Hepatocellular Carcinoma
    Wildner, Dane
    Schlitt, Hans Juergen
    Baeuerle, Tobias
    Haibach, Martina
    ZEITSCHRIFT FUR GASTROENTEROLOGIE, 2023, 61 (12): : 1618 - 1622
  • [47] Characterization of a hepatic haemangioma with contrast-enhanced ultrasound in an infant
    Piorkowska, Marta Anna
    Dezman, Rok
    Sellars, Maria E.
    Deganetto, Annamaria
    Sidhu, Paul S.
    ULTRASOUND, 2018, 26 (03) : 178 - 181
  • [48] Role of contrast-enhanced ultrasound in evaluation of the bowel
    Medellin, Alexandra
    Merrill, Christina
    Wilson, Stephanie R.
    ABDOMINAL RADIOLOGY, 2018, 43 (04) : 918 - 933
  • [49] The analysis of enhancement pattern of hepatic inflammatory pseudotumor on contrast-enhanced ultrasound
    Wen-Tao Kong
    Wen-Ping Wang
    Hao Cai
    Bei-Jian Huang
    Hong Ding
    Feng Mao
    Abdominal Imaging, 2014, 39 : 168 - 174
  • [50] The use of contrast-enhanced ultrasound (CEUS) for the diagnostic evaluation of hepatic echinococcosis
    Schwarze, V
    Mueller-Peltzer, K.
    de Figueiredo, G. Negrao
    Lindner, F.
    Ruebenthaler, J.
    Clevert, D-A
    CLINICAL HEMORHEOLOGY AND MICROCIRCULATION, 2018, 70 (04) : 449 - 455