Utility of Contrast-Enhanced Ultrasound in Optimizing Hepatic Abscess Treatment and Monitoring

被引:0
|
作者
Dobek, Adam [1 ]
Kobierecki, Mateusz [2 ]
Kosztowny, Konrad [3 ]
Grzasiak, Oliwia [3 ]
Fabisiak, Adam [4 ]
Falenta, Krzysztof [1 ]
Stefanczyk, Ludomir [1 ]
机构
[1] Med Univ Lodz, Norbert Barlicki Mem Teaching Hosp 1, Dept Radiol & Diag Imaging, PL-90153 Lodz, Poland
[2] Polish Mothers Mem Hosp Res Institite, Dept Diag Imaging, PL-90153 Lodz, Poland
[3] Med Univ Lodz, Norbert Barlicki Mem Teaching Hosp 1, Dept Gen Surg & Transplantol, PL-90153 Lodz, Poland
[4] Med Univ Lodz, Norbert Barlicki Mem Teaching Hosp 1, Dept Digest Tract Dis, PL-90153 Lodz, Poland
关键词
abscess; contrast-enhanced ultrasound; liver; percutaneous drainage; ultrasound; LIVER-ABSCESS; DRAINAGE; MANAGEMENT; CEUS;
D O I
10.3390/jcm13175046
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background/Objectives: Untreated hepatic abscesses (HAs) have an 80% mortality rate and can be caused by bacteria and fungi. Previously managed with surgery, current treatments now utilize interventional radiology and antibiotics, reducing complications to 2.5%. This study evaluates contrast-enhanced ultrasound (CEUS) for better drainage placement and monitoring, overcoming conventional ultrasound's limitations in detecting the HA liquefied portion. Methods: We conducted a retrospective study of 50 patients with HAs confirmed via computed tomography (CT) scans. Inclusion criteria comprised specific clinical symptoms and laboratory parameters. Both B-mode and CEUS were utilized for initial and follow-up imaging. Results: In the CEUS studies, the mean size of HAs was 6.26 cm, with pus displaying significantly lower echogenicity compared to the HA pouch and liver parenchyma in all phases. Classification by size (>6 cm, <6 cm) and volume (>113 mL, <113 mL) revealed differences in the assessment of fluid volume between CEUS and B-mode. Conclusions: CEUS is valuable for diagnosing, performing therapeutic procedures, and monitoring HA. It provides precise real-time assessment of HA morphology, including dimensions and volume. If the liquefied volume of an HA exceeds 113 mL, it may qualify for drainage placement. CEUS can replace CT as an effective, less harmful, and cheaper method, eliminating the need for multiple radiological departments. While CEUS is a safer, cost-effective alternative to CT for HA evaluation and monitoring, comprehensive clinical evaluation remains essential. Therefore, CEUS should be part of a broader diagnostic and monitoring strategy, not a stand-alone solution.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] Pediatric contrast-enhanced ultrasound in the United States: a survey by the Contrast-Enhanced Ultrasound Task Force of the Society for Pediatric Radiology
    Back, Susan J.
    Maya, Carolina
    Darge, Kassa
    Acharya, Patricia T.
    Barnewolt, Carol E.
    Coleman, Jamie L.
    Dillman, Jonathan R.
    Fordham, Lynn Ansley
    Hwang, Misun
    Lim, Annie
    McCarville, M. Beth
    Munden, Marthe M.
    Paltiel, Harriet J.
    Volberg, Frank M.
    PEDIATRIC RADIOLOGY, 2018, 48 (06) : 852 - 857
  • [32] Contrast-enhanced ultrasound of transplant organs - liver and kidney - in children
    Franke, Doris
    Daugherty, Reza J.
    Kljucevsek, Damjana
    Ntoulia, Aikaterini
    Rafailidis, Vasileios
    Takahashi, Marcelo S.
    Torres, Alvaro
    Viteri, Bernarda
    Volberg, Frank M.
    PEDIATRIC RADIOLOGY, 2021, 51 (12) : 2284 - 2302
  • [33] Contrast-enhanced and targeted ultrasound
    Michiel Postema
    Odd Helge Gilja
    World Journal of Gastroenterology, 2011, 17 (01) : 28 - 41
  • [34] Endocavitary Contrast-Enhanced Ultrasound
    Vollert, Kurt
    Clevert, Dirk Andre
    Kleffel, Timm
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2022, 194 (11): : 1204 - 1214
  • [35] The analysis of enhancement pattern of hepatic inflammatory pseudotumor on contrast-enhanced ultrasound
    Kong, Wen-Tao
    Wang, Wen-Ping
    Cai, Hao
    Huang, Bei-Jian
    Ding, Hong
    Mao, Feng
    ABDOMINAL IMAGING, 2014, 39 (01): : 168 - 174
  • [36] Contrast-Enhanced Ultrasound: Practical Review for the Assessment of Hepatic and Renal Lesions
    Denham, Stephanie LeeAnn Wilson
    Alexander, Lauren F.
    Robbin, Michelle L.
    ULTRASOUND QUARTERLY, 2016, 32 (02) : 116 - 125
  • [37] Update in Contrast-Enhanced Ultrasound
    Beckmann, Steffen
    Simanowski, Joerg H.
    VISCERAL MEDICINE, 2020, 36 (06) : 476 - 486
  • [38] Contrast-enhanced and targeted ultrasound
    Postema, Michiel
    Gilja, Odd Helge
    WORLD JOURNAL OF GASTROENTEROLOGY, 2011, 17 (01) : 28 - 41
  • [39] Prospective Assessment of Treatment-Induced Liver Injury as a Cause of Diffuse Pathologic Hepatic Enhancement in Contrast-Enhanced Ultrasound
    Wiemers, Hannah
    Burchert, Andreas
    Michel, Christian
    Sohlbach, Kristina
    Schafer, Jonas
    Neubauer, Andraes
    Goerg, Christian
    Trenker, Corinna
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2024, 50 (02) : 224 - 228
  • [40] Contrast-Enhanced Ultrasound for the Characterization of Infantile Hepatic Hemangioma in Premature Neonate
    Sekej, Marjan
    Donlagic, Sabina Vadnjal
    Kljucevsek, Damjana
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2020, 12 (08)