Utility of Contrast-Enhanced Ultrasound in Optimizing Hepatic Abscess Treatment and Monitoring

被引:0
|
作者
Dobek, Adam [1 ]
Kobierecki, Mateusz [2 ]
Kosztowny, Konrad [3 ]
Grzasiak, Oliwia [3 ]
Fabisiak, Adam [4 ]
Falenta, Krzysztof [1 ]
Stefanczyk, Ludomir [1 ]
机构
[1] Med Univ Lodz, Norbert Barlicki Mem Teaching Hosp 1, Dept Radiol & Diag Imaging, PL-90153 Lodz, Poland
[2] Polish Mothers Mem Hosp Res Institite, Dept Diag Imaging, PL-90153 Lodz, Poland
[3] Med Univ Lodz, Norbert Barlicki Mem Teaching Hosp 1, Dept Gen Surg & Transplantol, PL-90153 Lodz, Poland
[4] Med Univ Lodz, Norbert Barlicki Mem Teaching Hosp 1, Dept Digest Tract Dis, PL-90153 Lodz, Poland
关键词
abscess; contrast-enhanced ultrasound; liver; percutaneous drainage; ultrasound; LIVER-ABSCESS; DRAINAGE; MANAGEMENT; CEUS;
D O I
10.3390/jcm13175046
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background/Objectives: Untreated hepatic abscesses (HAs) have an 80% mortality rate and can be caused by bacteria and fungi. Previously managed with surgery, current treatments now utilize interventional radiology and antibiotics, reducing complications to 2.5%. This study evaluates contrast-enhanced ultrasound (CEUS) for better drainage placement and monitoring, overcoming conventional ultrasound's limitations in detecting the HA liquefied portion. Methods: We conducted a retrospective study of 50 patients with HAs confirmed via computed tomography (CT) scans. Inclusion criteria comprised specific clinical symptoms and laboratory parameters. Both B-mode and CEUS were utilized for initial and follow-up imaging. Results: In the CEUS studies, the mean size of HAs was 6.26 cm, with pus displaying significantly lower echogenicity compared to the HA pouch and liver parenchyma in all phases. Classification by size (>6 cm, <6 cm) and volume (>113 mL, <113 mL) revealed differences in the assessment of fluid volume between CEUS and B-mode. Conclusions: CEUS is valuable for diagnosing, performing therapeutic procedures, and monitoring HA. It provides precise real-time assessment of HA morphology, including dimensions and volume. If the liquefied volume of an HA exceeds 113 mL, it may qualify for drainage placement. CEUS can replace CT as an effective, less harmful, and cheaper method, eliminating the need for multiple radiological departments. While CEUS is a safer, cost-effective alternative to CT for HA evaluation and monitoring, comprehensive clinical evaluation remains essential. Therefore, CEUS should be part of a broader diagnostic and monitoring strategy, not a stand-alone solution.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Comparative efficacy of contrast-enhanced ultrasound versus B-mode ultrasound in the diagnosis and monitoring of hepatic abscesses
    Dobek, Adam
    Kobierecki, Mateusz
    Ciesielski, Wojciech
    Grzasiak, Oliwia
    Kosztowny, Konrad
    Fabisiak, Adam
    Bialek, Piotr
    Stefanczyk, Ludomir
    POLISH JOURNAL OF RADIOLOGY, 2024, 89 : e470 - e479
  • [2] Contrast-Enhanced Ultrasound of the Liver: Optimizing Technique and Clinical Applications
    Pang, Emily H. T.
    Chan, Andy
    Ho, Stephen G.
    Harris, Alison C.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2018, 210 (02) : 320 - 332
  • [3] Intracavitary contrast-enhanced ultrasound in abscess drainage - feasibility and clinical value
    Ignee, Andre
    Jenssen, Christian
    Cui, Xin-Wu
    Schuessler, Gudrun
    Dietrich, Christoph Frank
    SCANDINAVIAN JOURNAL OF GASTROENTEROLOGY, 2016, 51 (01) : 41 - 47
  • [4] CLINICAL UTILITY OF CONTRAST-ENHANCED ULTRASOUND FOR THE DIAGNOSIS OF LYMPHADENOPATHY
    Huang, Siyang
    Zhao, Yunuo
    Jiang, Xian
    Lin, Nan
    Zhang, Mingxuan
    Wang, Hang
    Zheng, Aiping
    Ma, Xuelei
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2021, 47 (04) : 869 - 879
  • [5] Percutaneous drainage of a parotid gland abscess under contrast-enhanced ultrasound guidance: A case report
    Scattergood, Sean
    Moore, Stephen
    Prior, Andrew
    Yusuf, Gibran T.
    Sidhu, Paul S.
    ULTRASOUND, 2018, 26 (03) : 182 - 186
  • [6] Microbubbles in the belly: optimizing the protocol for contrast-enhanced ultrasound of the pediatric abdomen
    Davis, Lauramay
    Back, Susan J.
    PEDIATRIC RADIOLOGY, 2023, 53 (07) : 1224 - 1236
  • [7] Contrast-enhanced ultrasound (CEUS) appearance of hepatic myelolipoma
    Menozzi G.
    Maccabruni V.
    Marini G.
    Froio E.
    Garlassi E.
    Journal of Ultrasound, 2016, 19 (1) : 61 - 65
  • [8] Contrast-enhanced ultrasound in diagnosis of primary hepatic angiosarcoma
    Ling, Wenwu
    Qiu, Tingting
    Ma, Lin
    Lei, Chuanfen
    Luo, Yan
    JOURNAL OF MEDICAL ULTRASONICS, 2017, 44 (03) : 267 - 270
  • [9] Effect of contrast-enhanced ultrasound on differential diagnosis of intrahepatic cholangiocarcinoma and arterial phase enhanced hepatic inflammatory lesions
    Yin, Shanshan
    Cui, Qiuli
    Yan, Kun
    Yang, Wei
    Wu, Wei
    Bao, Liping
    Chen, Minhua
    CHINESE JOURNAL OF CANCER RESEARCH, 2017, 29 (03) : 272 - 280
  • [10] The Utility and Limitations of Contrast-Enhanced Ultrasound for the Diagnosis and Treatment of Prostate Cancer
    Sano, Futoshi
    Uemura, Hiroji
    SENSORS, 2015, 15 (03): : 4947 - 4957