Performance and feasibility study of a heat pump with modified solar-air source evaporator: Techno-economic analysis for water heating

被引:3
|
作者
Chinnasamy, Subramaniyan [1 ]
Prakash, K. B. [1 ]
Divyabharathi, R. [2 ]
Kalidasan, B. [3 ]
Rajamony, Reji Kumar [4 ,5 ]
Pandey, A. K. [3 ,6 ]
Fouad, Yasser [7 ]
Soudagar, Manzoore Elahi M. [8 ,9 ]
机构
[1] Bannari Amman Inst Technol, Dept Mech Engn, Sathyamangalam 638401, Tamil Nadu, India
[2] Tamil Nadu Agr Univ, Dept Renewable Energy Engn, AEC &RI, Coimbatore 641003, India
[3] Sunway Univ, Res Ctr Nanomat & Energy Technol RCNMET, Sch Engn & Technol, Jalan Univ 5, Petaling Jaya 47500, Selangor Darul, Malaysia
[4] Natl Energy Univ, Univ Tenaga Nas, Inst Sustainable Energy, Jalan IKRAM UNITEN, Kajang, Selangor, Malaysia
[5] SIMATS, Saveetha Sch Engn, Dept Phys, Chennai 602105, India
[6] Uttaranchal Univ, CoE Energy & Ecosustainabil Res, Dehra Dun 248007, Uttarakhand, India
[7] King Saud Univ, Coll Appl Engn, Dept Appl Mech Engn, Muzahimiyah Branch, POB 800, Riyadh 11421, Saudi Arabia
[8] Lishui Univ, Fac Engn, Lishui 323000, Zhejiang, Peoples R China
[9] Era Graph, Dept Mech Engn, Dehra Dun 248002, Uttarakhand, India
关键词
Dual source; COP; Exergy; Heat pump; Carbon credit; Payback period; THERMAL PERFORMANCE; EXPERIMENTAL VALIDATION; ENERGY-CONSUMPTION; SYSTEM; SIMULATION; REFRIGERANTS; EMISSIONS; ASHP;
D O I
10.1016/j.icheatmasstransfer.2024.107795
中图分类号
O414.1 [热力学];
学科分类号
摘要
There is a rising demand for improving and analyzing the potential of alternative designs and operating conditions of heat pumps. The current study explores and reports on the techno-economic analysis (4E - Energy, Exergy, economic and environmental viability) of a Modified Dual Source Heat Pump (MDHP) water heater under various ambient and operating circumstances. There are three functioning modes are presented for operating the system all over the day irrespective of the ambient conditions: dual source with natural convection (MDHP-DN), dual source with forced convection (MDHP-DF), and air-source forced convection (MDHP-AF). The experimental analysis targeted to assess the system's overall performance under diverse design and operating conditions all over the day. The outcomes specify that the average COP of MDHP in dual source with natural convection mode (DN) is 7% and 18% larger than that of dual source with forced convection (DF) and (AF), respectively. The regular daily COP and exergy efficiency of MDHP (with five heat-up cycles per day) are 3.24 and 54.6%, respectively. Furthermore, the investigation into the annual effectiveness of the MDHP involves analyzing simulation studies that take into account the local ambient conditions. According to the results, the MDHP system has a payback period of around 689 days and a lifetime CO2 mitigation savings cost of approximately $178,057 compared to a conventional electric heating system. This inference implies that the suggested MDHP system can be adapted to varying weather conditions, providing active and long-term solutions compared with conventional heat pump water heating systems.
引用
收藏
页数:19
相关论文
共 50 条
  • [31] CLIMATE ADAPTATION ANALYSIS OF A SOLAR-AIR COMPOSITE HEAT SOURCE HEAT PUMP SYSTEM
    Liu, Y.
    Zhou, G. H.
    Shen, J. Y.
    7TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATING AND AIR CONDITIONING, PROCEEDINGS OF ISHVAC 2011, VOLS I-IV, 2011, : 840 - 845
  • [32] Experimental investigation and performance evaluation on a direct expansion solar-air source heat pump system
    Wang, Changling
    Gao, Yuanzhi
    Dai, Zhaofeng
    Wu, Dongxu
    Huang, Ziqi
    Zhang, Xiaosong
    Jiang, Luling
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2023, 145 : 168 - 176
  • [33] Techno-economic analysis of flexible heat pump controls
    Nolting, Lars
    Praktiknjo, Aaron
    APPLIED ENERGY, 2019, 238 : 1417 - 1433
  • [34] Techno-economic feasibility of absorption heat pumps using wastewater as the heating source for desalination
    Li, Hanning
    Russell, Nigel
    Sharifi, Vida
    Swithenbank, Jim
    DESALINATION, 2011, 281 : 118 - 127
  • [35] EXPERIMENTAL STUDY ON PERFORMANCE OF SOLAR-AIR ENERGY DUAL SOURCE COLLECTOR EVAPORATOR BASED ON FLAT HEAT PIPE
    Lou X.
    Quan Z.
    Zhao Y.
    Du B.
    Hou L.
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2023, 44 (01): : 119 - 125
  • [36] Performance assessment and techno-economic optimization of ground source heat pump for residential heating and cooling: A case study of Nanjing, China
    Zhou, Kun
    Mao, Jinfeng
    Li, Yong
    Zhang, Hua
    SUSTAINABLE ENERGY TECHNOLOGIES AND ASSESSMENTS, 2020, 40
  • [37] Techno-economic analysis of air source absorption heat pump: Improving economy from a design perspective
    Wu, Wei
    Wang, Baolong
    Shi, Wenxing
    Li, Xianting
    ENERGY AND BUILDINGS, 2014, 81 : 200 - 210
  • [38] Techno-economic analysis of air-source heat pump (ASHP) technology for single-detached home heating applications in Canada
    Udovichenko, Artur
    Zhong, Lexuan
    SCIENCE AND TECHNOLOGY FOR THE BUILT ENVIRONMENT, 2020, 26 (10) : 1352 - 1370
  • [39] COMPARATIVE STUDY OF THE PERFORMANCE OF TWO GREENHOUSE HEATING TECHNIQUES: SOLAR AIR HEATER AND HEAT PUMP
    Sellami, Douja
    Boughanmi, Hassen
    Bouadila, Salwa
    Ghorbel, Abdelwahed
    Ben Salem-Fnayou, Asma
    HEAT TRANSFER RESEARCH, 2019, 50 (12) : 1127 - 1147
  • [40] Energy and exergy analysis of a novel solar-air composite source multi-functional heat pump
    Cai, Jingyong
    Zhou, Haihua
    Xu, Lijie
    Shi, Zhengrong
    Zhang, Tao
    Ji, Jie
    RENEWABLE ENERGY, 2022, 185 (32-46) : 32 - 46