Dose profile measurement using an imaging plate: Evaluation of filters using Monte Carlo simulation of 4 MV x-rays

被引:0
|
作者
Hashimoto, Masatoshi [1 ,2 ]
Tomita, Tetsuya [3 ]
Sawada, Koichi [3 ]
Fujibuchi, Toshioh [4 ]
Nishio, Teiji [5 ]
Nakagawa, Keiichi [1 ]
机构
[1] Univ Tokyo, Grad Sch Med, Div Radiol & Biomed Engn, Bunkyo Ku, Tokyo 1138655, Japan
[2] Med Plaza Edogawa, Dept Therapeut Radiol, Edogawa Ku, Tokyo 1330052, Japan
[3] Chiba Univ Hosp, Dept Radiol, Cyuo Ku, Chiba 2608677, Japan
[4] Ibaraki Prefectural Univ, Sch Hlth Sci, Dept Radiol Sci, Ibaraki 3000394, Japan
[5] Natl Canc Ctr Hosp E, Res Ctr Innovat Oncol, Particle Therapy Div, Kashiwa, Chiba 2778577, Japan
关键词
diagnostic radiography; dosimetry; filters; lead; Monte Carlo methods; X-ray apparatus; HIGH-ENERGY PHOTON; FILM DOSIMETRY; COMPUTED RADIOGRAPHY; RADIATION-THERAPY; QUALITY-ASSURANCE; EBT FILM; BEAMS; RECONSTRUCTION; SPECTRA;
D O I
10.1063/1.3103572
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Computed radiography (CR) is gradually replacing film. The application of CR for two-dimensional profiles and off-axis ratio (OAR) measurement using an imaging plate (IP) in a CR system is currently under discussion. However, a well known problem for IPs in dosimetry is that they use high atomic number (Z) materials, such as Ba, which have an energy dependency in a photon interaction. Although there are some reports that it is possible to compensate for the energy dependency with metal filters, the appropriate thicknesses of these filters and where they should be located have not been investigated. The purpose of this study is to find the most suitable filter for use with an IP as a dosimetric tool. Monte Carlo simulation (Geant4 8.1) was used to determine the filter to minimize the measurement error in OAR measurements of 4 MV x-rays. In this simulation, the material and thickness of the filter and distance between the IP and the filter were varied to determine most suitable filter conditions that gave the best fit to the MC calculated OAR in water. With regard to changing the filter material, we found that using higher Z and higher density material increased the effectiveness of the filter. Also, increasing the distance between the filter and the IP reduced the effectiveness, whereas increasing the thickness of the filter increased the effectiveness. The result of this study showed that the most appropriate filter conditions consistent with the calculated OAR in water were the ones with the IP sandwiched between two 2 mm thick lead filters at a distance of 5 mm from the IP or the IP sandwiched directly between two 1 mm lead filters. Using these filters, we measured the OAR at 10 cm depth with 100 cm source-to-surface distance and surface 10x10 cm(2) field size. The results of this measurement represented that it is possible to achieve measurements with less than within 2.0% and 2.0% in the field and with less than 1.1% and 0.6% out of the field by using 2 and 1 mm lead filters, respectively.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] A detailed experimental and Monte Carlo analysis of gold nanoparticle dose enhancement using 6 MV and 18 MV external beam energies in a macroscopic scale
    Gray, Tara
    Bassiri, Nema
    David, Shaquan
    Patel, Devanshi Yogeshkumar
    Stathakis, Sotirios
    Kirby, Neil
    Mayer, Kathryn M.
    APPLIED RADIATION AND ISOTOPES, 2021, 171
  • [42] A trial for fine and low-dose imaging of biological specimens using quasi-monochromatic laser-Compton X-rays
    Yamada, K.
    Kuroda, R.
    Toyakawa, H.
    Ikeura-Sekiguchi, H.
    Yasumoto, M.
    Koike, M.
    Sakai, F.
    Mori, K.
    Mori, H.
    Fukuyama, N.
    Sato, E.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 608 (01) : S7 - S10
  • [43] A dose point kernel database using GATE Monte Carlo simulation toolkit for nuclear medicine applications: Comparison with other Monte Carlo codes
    Papadimitroulas, Panagiotis
    Loudos, George
    Nikiforidis, George C.
    Kagadis, George C.
    MEDICAL PHYSICS, 2012, 39 (08) : 5238 - 5247
  • [44] Evaluation of fetal dose during pelvimetry CT scan procedure by Monte Carlo using GATE
    Aabid, M.
    Semghouli, S.
    Amaoui, B.
    Choukri, A.
    RADIATION PHYSICS AND CHEMISTRY, 2023, 210
  • [45] X-ray fluorescence computed tomography (XFCT) imaging of gold nanoparticle-loaded objects using 110 kVp x-rays
    Cheong, Seong-Kyun
    Jones, Bernard L.
    Siddiqi, Arsalan K.
    Liu, Fang
    Manohar, Nivedh
    Cho, Sang Hyun
    PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (03) : 647 - 662
  • [46] New technique for effective dose estimation using Monte Carlo simulation for the patients undergoing radioiodine therapy
    Jokic, Vesna Spasic
    Kocovska, Marina Zdraveska
    MEASUREMENT, 2013, 46 (01) : 795 - 802
  • [47] Development of a dose verification system for Vero4DRT using Monte Carlo method
    Ishihara, Yoshitomo
    Sawada, Akira
    Nakamura, Mitsuhiro
    Miyabe, Yuki
    Tanabe, Hiroaki
    Kaneko, Shuji
    Takayama, Kenji
    Mizowaki, Takashi
    Kokubo, Masaki
    Hiraoka, Masahiro
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2014, 15 (06): : 160 - 172
  • [48] Fetal Organ Dose Assessment during Chest CT Examination Using Monte Carlo/Gate Simulation
    Benameur, Y.
    Tahiri, M.
    Mkimel, M.
    El Baydaoui, R.
    El Hariri, B.
    Mesradi, M. R.
    Hilali, A.
    Saad, E.
    PHYSICS OF PARTICLES AND NUCLEI LETTERS, 2023, 20 (04) : 690 - 698
  • [49] Calculation of Dose Distribution of Accuboost Brachytherapy in Deformable Polyvinil Alcohol Breast Phantom Using Biomechanical Modeling and Monte Carlo Simulation
    Mohammadyari, P.
    Faghihi, R.
    Shirazi, M. Mosleh
    Lotfi, M.
    Meigooni, A.
    MEDICAL PHYSICS, 2014, 41 (06) : 235 - +
  • [50] SPECT performance evaluation on image of Yttrium 90-Bremsstrahlung using Monte Carlo simulation
    Orejuela, Carlos O. Pastrana
    Coelho, Francisco de Assis
    Oliveira, Susie Medeiros
    Souza, Sergio A. L.
    de Sa, Lidia Vasconcellos
    da Silva, Ademir Xavier
    Berdeguez, Mirta B. Torres
    APPLIED RADIATION AND ISOTOPES, 2021, 168