Dose profile measurement using an imaging plate: Evaluation of filters using Monte Carlo simulation of 4 MV x-rays

被引:0
|
作者
Hashimoto, Masatoshi [1 ,2 ]
Tomita, Tetsuya [3 ]
Sawada, Koichi [3 ]
Fujibuchi, Toshioh [4 ]
Nishio, Teiji [5 ]
Nakagawa, Keiichi [1 ]
机构
[1] Univ Tokyo, Grad Sch Med, Div Radiol & Biomed Engn, Bunkyo Ku, Tokyo 1138655, Japan
[2] Med Plaza Edogawa, Dept Therapeut Radiol, Edogawa Ku, Tokyo 1330052, Japan
[3] Chiba Univ Hosp, Dept Radiol, Cyuo Ku, Chiba 2608677, Japan
[4] Ibaraki Prefectural Univ, Sch Hlth Sci, Dept Radiol Sci, Ibaraki 3000394, Japan
[5] Natl Canc Ctr Hosp E, Res Ctr Innovat Oncol, Particle Therapy Div, Kashiwa, Chiba 2778577, Japan
关键词
diagnostic radiography; dosimetry; filters; lead; Monte Carlo methods; X-ray apparatus; HIGH-ENERGY PHOTON; FILM DOSIMETRY; COMPUTED RADIOGRAPHY; RADIATION-THERAPY; QUALITY-ASSURANCE; EBT FILM; BEAMS; RECONSTRUCTION; SPECTRA;
D O I
10.1063/1.3103572
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Computed radiography (CR) is gradually replacing film. The application of CR for two-dimensional profiles and off-axis ratio (OAR) measurement using an imaging plate (IP) in a CR system is currently under discussion. However, a well known problem for IPs in dosimetry is that they use high atomic number (Z) materials, such as Ba, which have an energy dependency in a photon interaction. Although there are some reports that it is possible to compensate for the energy dependency with metal filters, the appropriate thicknesses of these filters and where they should be located have not been investigated. The purpose of this study is to find the most suitable filter for use with an IP as a dosimetric tool. Monte Carlo simulation (Geant4 8.1) was used to determine the filter to minimize the measurement error in OAR measurements of 4 MV x-rays. In this simulation, the material and thickness of the filter and distance between the IP and the filter were varied to determine most suitable filter conditions that gave the best fit to the MC calculated OAR in water. With regard to changing the filter material, we found that using higher Z and higher density material increased the effectiveness of the filter. Also, increasing the distance between the filter and the IP reduced the effectiveness, whereas increasing the thickness of the filter increased the effectiveness. The result of this study showed that the most appropriate filter conditions consistent with the calculated OAR in water were the ones with the IP sandwiched between two 2 mm thick lead filters at a distance of 5 mm from the IP or the IP sandwiched directly between two 1 mm lead filters. Using these filters, we measured the OAR at 10 cm depth with 100 cm source-to-surface distance and surface 10x10 cm(2) field size. The results of this measurement represented that it is possible to achieve measurements with less than within 2.0% and 2.0% in the field and with less than 1.1% and 0.6% out of the field by using 2 and 1 mm lead filters, respectively.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Influence of distant scatterer on air kerma measurement in the evaluation of diagnostic X-rays using Monte Carlo simulation
    Tominaga, Masahide
    Nagayasu, Yukari
    Sasaki, Motoharu
    Furuta, Takuya
    Hayashi, Hiroaki
    Oita, Masataka
    Nishiyama, Yuichi
    Haga, Akihiro
    RADIOLOGICAL PHYSICS AND TECHNOLOGY, 2021, 14 (04) : 381 - 389
  • [2] Influence of distant scatterer on air kerma measurement in the evaluation of diagnostic X-rays using Monte Carlo simulation
    Masahide Tominaga
    Yukari Nagayasu
    Motoharu Sasaki
    Takuya Furuta
    Hiroaki Hayashi
    Masataka Oita
    Yuichi Nishiyama
    Akihiro Haga
    Radiological Physics and Technology, 2021, 14 : 381 - 389
  • [3] Scatter radiation dose profile evaluation in computed tomography using Monte Carlo simulation
    Mohammadi, Gh R. Fallah
    Hesamnezhad, L.
    Mahdavi, M.
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2021, 19 (04): : 813 - 818
  • [4] Measured and Monte Carlo simulated surface dose reduction for superficial X-rays incident on tissue with underlying air or bone
    Baines, John
    Zawlodzka, Sylwia
    Markwell, Tim
    Chan, Millicent
    MEDICAL PHYSICS, 2018, 45 (02) : 926 - 933
  • [5] Monte Carlo modeling of radiation dose from radiation therapy with superficial x-rays
    Barghash, Reham
    Martin, Tiffany W.
    Prebble, Amber R.
    Leary, Del
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2025,
  • [6] Monte Carlo simulation of the dose deposited into GAFCHROMIC® film by X-rays produced by the electron beam of PFMA-3
    Ceccolini, E.
    Rocchi, F.
    Mostacci, D.
    Sumini, M.
    Tartani, A.
    RADIATION MEASUREMENTS, 2012, 47 (10) : 1000 - 1004
  • [7] Irradiation of gold nanoparticles by x-rays: Monte Carlo simulation of dose enhancements and the spatial properties of the secondary electrons production
    Leung, Michael K. K.
    Chow, James C. L.
    Chithrani, B. Devika
    Lee, Martin J. G.
    Oms, Barbara
    Jaffray, David A.
    MEDICAL PHYSICS, 2011, 38 (02) : 624 - 631
  • [8] Target-filter combination effects on breast tissue characterization using mammographic X-rays: A Monte Carlo simulation study
    Elshemey, Wael M.
    Saif, Refat Abo
    Elfiky, Abdo A.
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2022, 30 (04) : 823 - 834
  • [9] A study on radiation interactions, dose enhancement, and hydrolysis with metallic nanoparticles irradiated by 6 megavoltage X-rays: Geant4 Monte Carlo simulation
    Batooei, Sepehr
    Moslehi, Amir
    Islamian, Jalil Pirayesh
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2022, 526 : 19 - 28
  • [10] Evaluation of glandular dose in mammography in presence of breast cysts using Monte Carlo simulation
    Deevband, Mohammad Reza
    Kaveh, Zeinab
    Ghorbani, Mahdi
    Khajetash, Benyamin
    POLISH JOURNAL OF MEDICAL PHYSICS AND ENGINEERING, 2021, 27 (01): : 41 - 50