Feasibility and Reproducibility of Isokinetic Dynamometry in Children with Neuromuscular Diseases

被引:1
|
作者
van der Woude, Danny R. [1 ]
Takken, Tim [1 ]
Ruyten, Thijs [1 ]
Asselman, Fay-Lynn [2 ]
van Eijk, Ruben P. A. [2 ]
van der Pol, W. Ludo [2 ]
Bartels, Bart [1 ]
机构
[1] Univ Med Ctr Utrecht, Wilhelmina Childrens Hosp, Child Dev & Exercise Ctr, Lundlaan 6, NL-3584 EA Utrecht, Netherlands
[2] Univ Med Ctr Utrecht, UMC Utrecht Brain Ctr, Dept Neurol & Neurosurg, NL-3584 CX Utrecht, Netherlands
关键词
isokinetic dynamometry; children; neuromuscular diseases; strength; power; TEST-RETEST RELIABILITY; 6-MINUTE WALK TEST; STRENGTH MEASUREMENTS; MUSCLE STRENGTH; END-POINTS; VALIDITY; COEFFICIENTS; GUIDELINE; AGREEMENT; BIODEX;
D O I
10.3390/jcm13175285
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background/Objectives: High-precision measurement tools are needed to measure relevant changes in strength and power in children with neuromuscular diseases. The aim of this study was to determine the feasibility (i), reproducibility (ii), and validity (iii) of isokinetic dynamometry in this population. Methods: Isometric and isokinetic knee and elbow flexion and extension were measured twice on the same day. Feasibility was based on completion rate and acceptability. Acceptability was measured with a 100 mm visual analog scale. We measured reproducibility as the intraclass correlation coefficient (ICC-agreement), standard error of measurement (SEM), and smallest detectable change (SDC). We investigated relationships between isometric strength and isokinetic power with Pearson's correlation coefficient. ROC curves were used to determine the cutoff of isometric strength to conduct isokinetic measurements. Results: Fifty children with NMDs participated with completion rates of 78-90% for isometric and 39-75% for isokinetic measurements. Acceptability was high (mean (SD) = 73 (19) mm). The ICCs for all measurements were over 0.9 (95% confidence interval (CI) = 0.932-0.998). The SEM% ranged from 5 to 14% and the SDC% from 14 to 28%. The correlations of strength and power were high (Pearson's correlation coefficient >0.9 (95% CI: 0.89-0.98)). The isometric strength needed to conduct isokinetic measurements ranged from 11.1 N in elbow flexors to 24.9 N in knee extensors. Conclusions: Isokinetic dynamometry is a feasible and reproducible method for measuring isometric strength in children with neuromuscular diseases with moderate weakness to normal strength, and isokinetic measurements are only feasible in knee extension for children with moderate weakness to normal strength. The convergent validity between isometric strength and power at low velocities is high.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] The reproducibility of isokinetic dynamometry data
    Caruso, John F.
    Brown, Lee E.
    Tufano, James J.
    ISOKINETICS AND EXERCISE SCIENCE, 2012, 20 (04) : 239 - 253
  • [2] The effect of velocity and familiarisation on the reproducibility of isokinetic dynamometry
    Nugent, Erin P.
    Snodgrass, Suzanne J.
    Callister, Robin
    ISOKINETICS AND EXERCISE SCIENCE, 2015, 23 (03) : 205 - 214
  • [3] Reliability of Muscle Strength and Muscle Power Assessments Using Isokinetic Dynamometry in Neuromuscular Diseases: A Systematic Review
    van der Woude, Danny R.
    Ruyten, Thijs
    Bartels, Bart
    PHYSICAL THERAPY, 2022, 102 (10):
  • [4] Use of Isokinetic Dynamometry To Assess Muscle Function In Burned Patients Is A Reliable Tool To Assist Progressive Resistance Exercise Prescription
    Dean, Julianna M.
    Murton, Andrew J.
    Glover, Shauna Q.
    Gutierrez, Ileana
    Andersen, Clark R.
    Herndon, David N.
    Lee, Jong O.
    Suman, Oscar E.
    JOURNAL OF BURN CARE & RESEARCH, 2023, 44 (03) : 546 - 550
  • [5] The effect of foot support on trunk strength assessment using isokinetic dynamometry
    Porto, Jaqueline Mello
    Marques, Nise Ribeiro
    Freire Junior, Renato Campos
    Carvalho de Abreu, Daniela Cristina
    ISOKINETICS AND EXERCISE SCIENCE, 2015, 23 (04) : 283 - 289
  • [6] Reliability of shoulder abduction muscle endurance measured using isokinetic dynamometry
    Micheletti, J. K.
    Andersen, L. L.
    Machado, A. F.
    Lopes, J. S. S.
    Souto, L. R.
    Pastre, C. M.
    SCIENCE & SPORTS, 2021, 36 (03) : E111 - E119
  • [7] Reproducibility of shoulder short range of motion in isokinetic and isometric strength testing
    Hadzic, Vedran
    Ursej, Eva
    Kalc, Milos
    Dervisevic, Edvin
    JOURNAL OF EXERCISE SCIENCE & FITNESS, 2012, 10 (02) : 83 - 89
  • [8] Isokinetic Testing in Patients with Neuromuscular Diseases A Focused Review
    El Mhandi, Lhassan
    Bethoux, Francois
    AMERICAN JOURNAL OF PHYSICAL MEDICINE & REHABILITATION, 2013, 92 (02) : 163 - 178
  • [9] The reproducibility of peak isometric torque and electromyography activity in unfamiliarised subjects using isokinetic dynamometry on repeated days
    Howatson, G
    van Someren, KA
    ISOKINETICS AND EXERCISE SCIENCE, 2005, 13 (02) : 103 - 109
  • [10] Absolute reliability and concurrent validity of hand held dynamometry and isokinetic dynamometry in the hip, knee and ankle joint: systematic review and meta-analysis
    Chamorro, Claudio
    Armijo-Olivo, Susan
    De la Fuente, Carlos
    Fuentes, Javiera
    Javier Chirosa, Luis
    OPEN MEDICINE, 2017, 12 (01): : 359 - 375